Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Clinical Evaluation of a Novel Trifocal IOL

14. maj 2026 opdateret af: Alcon Research
The purpose of this study is to understand the visual outcomes of the investigational intraocular lens (IOL) Model LPYWT0 when compared to the commercially marketed Clareon PanOptix Pro IOL Model PXYWT0.

Studieoversigt

Status

Ikke rekrutterer endnu

Betingelser

Detaljeret beskrivelse

In this study, subjects with cataracts in both eyes will undergo cataract surgery and be implanted with trifocal IOLs. One eye will receive the investigational IOL Model LPYWT0 IOL, and the other eye will receive the commercially marketed Clareon PanOptix Pro IOL Model PXYWT0. The second eye surgery will occur 7-14 days after the first. Subjects will attend 9 planned study visits to include for an individual duration of participation of approximately 7 months.

This study is planned to be conducted in India, The Philippines, Australia, and New Zealand.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

66

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

Studiesteder

      • Makati City, Filippinerne, 1200
        • Asian Eye Institute
    • Manila
      • Makati City, Manila, Filippinerne, 1209
        • Peregrine Eye Laser and Institute
      • Bangalore, Indien, 560010
        • Narayana Nethralaya
    • Tamil Nadu
      • Chennai, Tamil Nadu, Indien, 600018
        • Dr. Agarwal's Eye Hospital Limited

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

  • Voksen
  • Ældre voksen

Tager imod sunde frivillige

Ingen

Beskrivelse

Key Inclusion Criteria:

  • The calculated power needed for the artificial lens (IOL) must be between +15.0 and +25.0 D in each eye, designed to bring subject vision as close to "0.0" (neutral) as possible, meaning they will not be strongly nearsighted or farsighted after surgery.
  • Subjects must have low levels of astigmatism (misshapen cornea) in the eyes (less than 1.00 D).
  • In the doctor's opinion, the subjects have the potential to achieve good vision (0.2 logMAR, which is roughly 20/32 Snellen or better) in each eye after the surgery, when wearing the best possible spectacles or contact lenses.
  • Other protocol-specified inclusion criteria may apply.

Key Exclusion Criteria:

  • Clinically significant corneal diseases which may, according to the investigator's medical opinion, adversely affect visual outcomes.
  • Any ocular or systemic health condition or medical issue that, in the investigator's medical opinion, could make the study results unreliable, prevent the person from finishing the study, or increase their safety risk.
  • People who want to have one eye set for distance vision and the other for near vision.
  • The doctor expects significant blurry vision (astigmatism) after the procedure.
  • Other protocol-specified exclusion criteria may apply.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Dobbelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Andet: LPYWT0 / PXYWT0
Investigational IOL Model LPYWT0 implanted in the first operative eye during cataract surgery with Clareon PanOptix Pro IOL Model PXYWT0 in the second eye, as randomized. The second eye will be implanted 7-14 days after the first.
Removal of the cataractous lens by phacoemulsification followed by implantation of the IOL
Investigational blue light filtering trifocal IOL implanted in the capsular bag of the eye during cataract surgery intended to remain in the eye for the lifetime of the subject.
Commercially available blue light filtering trifocal IOL implanted in the capsular bag of the eye during cataract surgery intended to remain in the eye for the lifetime of the subject.
Andre navne:
  • Clareon® PanOptix® Pro
Andet: PXYWT0 / LPYWT0
Clareon PanOptix Pro IOL Model PXYWT0 implanted in the first operative eye during cataract surgery with investigational IOL Model LPYWT0 implanted in the second eye, as randomized. The second eye will be implanted 7-14 days after the first.
Removal of the cataractous lens by phacoemulsification followed by implantation of the IOL
Investigational blue light filtering trifocal IOL implanted in the capsular bag of the eye during cataract surgery intended to remain in the eye for the lifetime of the subject.
Commercially available blue light filtering trifocal IOL implanted in the capsular bag of the eye during cataract surgery intended to remain in the eye for the lifetime of the subject.
Andre navne:
  • Clareon® PanOptix® Pro

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Mean Monocular Photopic Best Corrected Distance Visual Acuity (BCDVA)
Tidsramme: Month 6 postoperative
Visual Acuity will be assessed using letter charts under well-lit (photopic) conditions with correction in place at a distance of 4 meters from the subject. BCDVA will be recorded in logarithm minimum angle of resolution (logMAR) where 0.0 logMAR is equivalent to 20/20 Snellen, or normal distance eyesight, and negative logMAR values represent better-than-normal distance eyesight.
Month 6 postoperative

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Sponsor

Efterforskere

  • Studieleder: Clinical Trial Lead, Surgical, Alcon Research, LLC

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Hjælpsomme links

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

1. oktober 2026

Primær færdiggørelse (Anslået)

1. juli 2027

Studieafslutning (Anslået)

1. juli 2027

Datoer for studieregistrering

Først indsendt

8. maj 2026

Først indsendt, der opfyldte QC-kriterier

8. maj 2026

Først opslået (Faktiske)

14. maj 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

18. maj 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

14. maj 2026

Sidst verificeret

1. maj 2026

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Cataract Surgery

Abonner