- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT02114749
Development of Tools for Respiration and Circulation Exploration (MAPO-RCVQ)
Development of Tools for Respiration and Circulation Studies and Exploration, Their Mutual Interactions and the Functions Involved in the Daily Life in Healthy Volunteers
Обзор исследования
Статус
Условия
Вмешательство/лечение
Подробное описание
The analysis and interpretation of a record consist, for example, to measure the amplitude of the respiratory modulation of the cardiac period, a witness of the level of the subject's sympathetic activity.
To do this, a mathematical model of this oscillation is adjusted on the experimental data, and its characteristics (amplitude, phase, non-linearity...) are considered indexes of the interaction to be compared with the same characteristics in other conditions.
The transition to clinical applications requires validation of the developed tools on physiological signals recorded on healthy volunteers in a non-clinical environment, avoiding extra psychological stress in the Protocol followed.
Whether it is for the development of tools or their validation, it is essential that the sensors used are non-invasive.
Recorded situations are those of everyday life, such as working (only sedentary work are envisaged), eat, talk, rest and move from one place of life to another one.
Тип исследования
Регистрация (Действительный)
Фаза
- Непригодный
Контакты и местонахождение
Места учебы
-
-
-
GRENOBLE cedex 9, Франция, 38043
- TIMC - pavillon Taillefer - CHU
-
Grenoble, Франция, 38043
- University Hospital
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
- healthy, major and socially insured human subjects
Exclusion Criteria:
- deprived of liberty, hospitalized and protected human subjects
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Фундаментальная наука
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: volunteers in daily life activities
a set of wearable respiration and cardiac monitoring devices
|
feasibility of methods for detecting physiological state changes from a set of wearable respiration and cardiac monitoring devices
Другие имена:
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Feasibility and use of developed methods and tools in clinical or fundamental research protocols or in systems for physiological monitoring in humans
Временное ограничение: up to 24 months
|
The new tools for identification and monitoring of the physiological state of a subject will be developed from a set of non-invasive measures at rest.
Resulting physiological state identification will then be validated on registrations on the same subjects in different daily life circumstances.
|
up to 24 months
|
Соавторы и исследователи
Спонсор
Следователи
- Главный следователь: Briot Raphaël, MD, University Hospital, Grenoble
Публикации и полезные ссылки
Общие публикации
- Fiamma MN, Straus C, Thibault S, Wysocki M, Baconnier P, Similowski T. Effects of hypercapnia and hypocapnia on ventilatory variability and the chaotic dynamics of ventilatory flow in humans. Am J Physiol Regul Integr Comp Physiol. 2007 May;292(5):R1985-93. doi: 10.1152/ajpregu.00792.2006. Epub 2007 Jan 11.
- Ben Lamine S, Calabrese P, Perrault H, Dinh TP, Eberhard A, Benchetrit G. Individual differences in respiratory sinus arrhythmia. Am J Physiol Heart Circ Physiol. 2004 Jun;286(6):H2305-12. doi: 10.1152/ajpheart.00655.2003. Epub 2004 Jan 29.
- Eberhard A, Calabrese P, Baconnier P, Benchetrit G. Comparison between the respiratory inductance plethysmography signal derivative and the airflow signal. Adv Exp Med Biol. 2001;499:489-94. doi: 10.1007/978-1-4615-1375-9_79. No abstract available.
- Emeriaud G, Eberhard A, Benchetrit G, Debillon T, Baconnier P. Calibration of respiratory inductance plethysmograph in preterm infants with different respiratory conditions. Pediatr Pulmonol. 2008 Nov;43(11):1135-1141. doi: 10.1002/ppul.20923.
- Fontecave-Jallon, Gumery P-Y, Calabrese P, Briot R, Baconnier P. A wearable technology revisited for cardio-respiratory functional exploration : Stroke volume estimation form respiratory inductive plethysmography. International journal of eHealth and Medical Communications, 4, 2013
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Действительный)
Завершение исследования (Действительный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Оценивать)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Другие идентификационные номера исследования
- University Hospital, Grenoble
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .