Effect of Silicon Oil on Retinal Electrical Functions Using Multifocal Electroretinogram (SO/RRD/mfERG)
Effect of Silicon Oil on Retinal Electrical Functions in Patients With Rhegmatogenous Retinal Detatchment Using Multifocal Electroretinogram .
Retinal detachment is one of the leading causes for permanent vision loss.Incidence of Rheugmatogenous Retinal Detachment (RRD) about 10.5 people per 100,000 population pars plana vitrectomy is the most popular and effective surgical options.
Tamponade agents as silicone oils are used to restore intraocular volume and apply surface tension to the detached retinal surface Silicone oil (SO) is a liquid containing polymerized siloxane with organic side chains. It has a high thermal stability, is hydrophobic, and chemically inert. The use of silicone oils as intraocular tamponades dates from 1962.
Обзор исследования
Статус
Условия
Вмешательство/лечение
Подробное описание
Retinal detachment is one of the leading causes for permanent vision loss.Incidence of Rheugmatogenous Retinal Detachment (RRD) about 10.5 people per 100,000 population pars plana vitrectomy is the most popular and effective surgical options.
Today, implanting silicone oil as a long-term tamponade is widespread and accepted. However, the oil can emulsify at the interface with its hydrophilic intraocular environment. Eyes treated with silicone oil that emulsifies can show up to 72% long-term complications, including corneal decompensation, band keratopathy, chronic elevations of intraocular pressure, opacification of the crystalline lens, retinopathies, and optic neuropathy.
Silicone oil floats in the vitreous cavity because the specific gravity is 0.97; its bubbles' surface tension may change after injection into the eye. Higher viscosity silicone oils have less emulsification.
In the vitreous cavity, buoyancy and gravity operate on an intraocular tamponade agent that presses against the retina as a downward force. Moreover, interfacial tension is the interaction between two immiscible chemicals, such silicone oil and aqueous humor.silicone oils have viscosities ranging from one thousand (MW 37 kDa) to five thousand (MW 65 kDa).
Multifocal electroretinography (mfERG) is an investigation that can simultaneously measure multiple electroretinographic responses at different retinal locations. mfERG allows topographic mapping of retinal function in the central 40-50° of the retina. The strength of mfERG lies in its ability to provide objective assessment of the central retinal function at different retinal areas within a short duration of time.The mfERG is taken under conditions of light adaptation in order to obtain an electrophysiological response from the cones.
Тип исследования
Регистрация (Оцененный)
Фаза
- Непригодный
Контакты и местонахождение
Контакты исследования
- Имя: Amany Nady Mohammed Mohammed, Resident
- Номер телефона: +201151849593
- Электронная почта: drmonmonnady92@gmail.com
Учебное резервное копирование контактов
- Имя: Amr Abdelrahman, professor
- Номер телефона: +201093292792
Места учебы
-
-
Minya Governorate
-
Minya, Minya Governorate, Египет, 61111
- Рекрутинг
- Faculty of Medicine
-
Контакт:
- Amany Mohammed, MBBCH
- Номер телефона: +201151849593
- Электронная почта: drmonmonnady92@gmail.com
-
Контакт:
- Amr A Abdelrahman, Lecturer
- Номер телефона: +201093292792
-
Главный следователь:
- Amany N Mohammed, MBBCH
-
-
Критерии участия
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Описание
Inclusion Criteria:
- Patients with primary rhegmatogenous retinal detachment
Exclusion Criteria:
- Patients with history of previous intraocular surgery.
- Patients with combined traction-rhegmatogenous retinal detachment
- Patients with ocular disease as glaucoma ,degenerative myopia,age related macular degeneration
- Patients with poor fixation.
- Uncooperative patients.
- Patients with retinopathy.
- emulsified SO or complicated SO removal were excluded from this study
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Диагностика
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Экспериментальный: Effect of Silicon Oil on Retinal Functions after Viterectomy
About the 50 patients suffering from Rhegmatogenous Retinal Detatchment.
All participants will undergo Viterectomy then the Retinal Functions will be evaluated by using Silicon oil tamponade recorded by Multi focal electroretinogram before and after the operation.
|
to evaluat the effect of silicon oil on retinal function in the eyes that underwent Pars Plana Vitrectomy with Silicon oil tamponade for Rheugmatogenous Retinal Detachment.
mfERG responses were recorded before and after Silicon oil removal .
Другие имена:
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Retinal Functions after vitrectomy
Временное ограничение: 1 Month to 3 Months
|
Evaluation of the Function of the Eye Retina after Vitrectomy for all the participants
|
1 Month to 3 Months
|
|
Electroretinogram Examination after vitrectomy
Временное ограничение: 1 Month to 3 Months
|
Electroretinogram examination which performed for all eyes after the vitrectomy as:When the light hits the eye, the photoreceptors (rods and cones) and other retinal cells generate small electrical impulses.
The Electroretinogram captures and graphs these impulses to evaluate if these cells are functioning normally or not.
|
1 Month to 3 Months
|
Соавторы и исследователи
Спонсор
Следователи
- Учебный стул: Mahmoud Mohammed M. Genedy, Professor, Department of Ophthalmology, fuculty of medicine,Minia University
Даты записи исследования
Изучение основных дат
Начало исследования (Действительный)
Первичное завершение (Оцененный)
Завершение исследования (Оцененный)
Даты регистрации исследования
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Другие идентификационные номера исследования
- Rhegmatogenous Retinal Detatch
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
продукт, произведенный в США и экспортированный из США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .