- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT07798037
Iatrogenic Atrial Septal Defect Gradient for Intraprocedural Success After M-teer (IASIS)
29 augusti 2026 uppdaterad av: Konstantinos Tsioufis, Hippocration General Hospital
Iatrogenic ASD Gradient as a Marker of Residual Mitral Regurgitation Severity After M-TEER Procedure
Transcatheter mitral edge-to-edge repair (M-TEER) has become an established minimally invasive therapy for patients with severe mitral regurgitation (MR) who are at high or prohibitive surgical risk.
However, accurate quantification of residual MR after M-TEER remains challenging.
In this direction, the hemodynamic significance of the post-procedural iatrogenic atrial septal defect (iASD) gradient is unknown.
The objective of this study is to assess the relationship between the post-procedural iASD pressure gradient and the severity of residual MR with intraprocedural echocardiographic and hemodynamic parameters.
Studieöversikt
Status
Aktiv, inte rekryterande
Betingelser
Intervention / Behandling
Detaljerad beskrivning
The present study plans to enroll patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy.
Patients with severe tricuspid regurgitation, post-procedural transmitral gradient >5 mmHg, right-to-left shunt requiring iASD closure, or refusal to provide written informed consent will be excluded.
All intraoperative transesophageal echo loops will be acquired using an EPIQ ultrasound system (Philips, Eindhoven, Netherlands) with an X8-2t transesophageal probe.
At the end of the procedure, in the mid-esophageal aortic valve short-axis view, flow across the iASD will be assessed immediately after catheter withdrawal from the left atrium using continuous-wave Doppler interrogation.
Through a cardiac cycle, the mean pressure gradient between the left and right atria will be calculated while maintaining hemodynamic stability.
Digitally stored image loops will be analyzed offline.
Blinded analysis will be performed by an independent investigator.
For assessment of residual MR, multiplanar reconstruction will be used, and the largest systolic 3D-VCA will be measured.
When multiple regurgitant jets are present, the total regurgitant orifice area will be calculated as the sum of the individual 3D-VCAs.
The primary endpoint is to determine the association and diagnostic performance of the post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER, as assessed by blinded offline 3D-VCA analysis.
Studietyp
Interventionell
Inskrivning (Beräknad)
100
Fas
- Inte tillämpbar
Kontakter och platser
Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.
Studieorter
-
-
-
Athens, Grekland, 11521
- First Cardiology Department, Hippokration General Hospital
-
-
Deltagandekriterier
Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.
Urvalskriterier
Åldrar som är berättigade till studier
- Vuxen
- Äldre vuxen
Tar emot friska volontärer
Nej
Beskrivning
Inclusion Criteria:
- patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy
- patients undergoing M-TEER as a bridge to heart transplantation
Exclusion Criteria:
- Patients with post-procedural transmitral gradient ≥5 mmHg,
- Patients with right-to-left shunt requiring iASD closure,
- Patients, who decline to provide written informed consent.
Studieplan
Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Diagnostisk
- Tilldelning: N/A
- Interventionsmodell: Enskild gruppuppgift
- Maskning: Ingen (Open Label)
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Övrig: M-TEER patients
high- or prohibitive-surgical-risk patients with severe mitral regurgitation
|
Hemodynamic and echocardiographic assessment of M-TEER procedural success
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER
Tidsram: The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
|
|
the cut-off point of iASD gradient for identifying mild or trivial mitral regurgitation after M-TEER procedure
Tidsram: 4 years
|
To determine the cut-off point of the post-procedural iASD gradient for identifying mild or trivial residual mitral regurgitation after M-TEER procedure
|
4 years
|
Samarbetspartners och utredare
Det är här du hittar personer och organisationer som är involverade i denna studie.
Sponsor
Publikationer och användbara länkar
Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.
Allmänna publikationer
- Sakul S, DiazSaravia S, Berman B, Dominguez AC, Lerakis S, Argulian E. "Echo-derived estimate of peak left atrial pressure in patients with iatrogenic atrial septal defects following transcatheter mitral edge-to-edge repair". Int J Cardiol. 2026 Feb 1;444:133975. doi: 10.1016/j.ijcard.2025.133975. Epub 2025 Oct 25.
- Zoghbi WA, Asch FM, Bruce C, Gillam LD, Grayburn PA, Hahn RT, Inglessis I, Islam AM, Lerakis S, Little SH, Siegel RJ, Skubas N, Slesnick TC, Stewart WJ, Thavendiranathan P, Weissman NJ, Yasukochi S, Zimmerman KG. Guidelines for the Evaluation of Valvular Regurgitation After Percutaneous Valve Repair or Replacement: A Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Angiography and Interventions, Japanese Society of Echocardiography, and Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr. 2019 Apr;32(4):431-475. doi: 10.1016/j.echo.2019.01.003. Epub 2019 Feb 20. No abstract available.
- Little SH, Quader N, Brady M, Dillenbeck A, Garcia-Sayan E, Jain R, Mackensen GB, Price MJ, Saric M, Scalia GM, Wang DD, Hahn RT. Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2026 Jun;39(6):529-550. doi: 10.1016/j.echo.2026.03.003.
Studieavstämningsdatum
Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.
Studera stora datum
Studiestart (Faktisk)
9 september 2024
Primärt slutförande (Beräknad)
10 juni 2028
Avslutad studie (Beräknad)
10 juni 2028
Studieregistreringsdatum
Först inskickad
11 juli 2026
Först inskickad som uppfyllde QC-kriterierna
29 augusti 2026
Första postat (Faktisk)
1 september 2026
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
1 september 2026
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
29 augusti 2026
Senast verifierad
1 augusti 2026
Mer information
Termer relaterade till denna studie
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- 22532/19-12-2023
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
OBESLUTSAM
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Nej
Studerar en amerikansk FDA-reglerad produktprodukt
Nej
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .