- ICH GCP
- Реестр клинических исследований США
- Клиническое испытание NCT07798037
Iatrogenic Atrial Septal Defect Gradient for Intraprocedural Success After M-teer (IASIS)
29 августа 2026 г. обновлено: Konstantinos Tsioufis, Hippocration General Hospital
Iatrogenic ASD Gradient as a Marker of Residual Mitral Regurgitation Severity After M-TEER Procedure
Transcatheter mitral edge-to-edge repair (M-TEER) has become an established minimally invasive therapy for patients with severe mitral regurgitation (MR) who are at high or prohibitive surgical risk.
However, accurate quantification of residual MR after M-TEER remains challenging.
In this direction, the hemodynamic significance of the post-procedural iatrogenic atrial septal defect (iASD) gradient is unknown.
The objective of this study is to assess the relationship between the post-procedural iASD pressure gradient and the severity of residual MR with intraprocedural echocardiographic and hemodynamic parameters.
Обзор исследования
Статус
Активный, не рекрутирующий
Вмешательство/лечение
Подробное описание
The present study plans to enroll patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy.
Patients with severe tricuspid regurgitation, post-procedural transmitral gradient >5 mmHg, right-to-left shunt requiring iASD closure, or refusal to provide written informed consent will be excluded.
All intraoperative transesophageal echo loops will be acquired using an EPIQ ultrasound system (Philips, Eindhoven, Netherlands) with an X8-2t transesophageal probe.
At the end of the procedure, in the mid-esophageal aortic valve short-axis view, flow across the iASD will be assessed immediately after catheter withdrawal from the left atrium using continuous-wave Doppler interrogation.
Through a cardiac cycle, the mean pressure gradient between the left and right atria will be calculated while maintaining hemodynamic stability.
Digitally stored image loops will be analyzed offline.
Blinded analysis will be performed by an independent investigator.
For assessment of residual MR, multiplanar reconstruction will be used, and the largest systolic 3D-VCA will be measured.
When multiple regurgitant jets are present, the total regurgitant orifice area will be calculated as the sum of the individual 3D-VCAs.
The primary endpoint is to determine the association and diagnostic performance of the post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER, as assessed by blinded offline 3D-VCA analysis.
Тип исследования
Интервенционный
Регистрация (Оцененный)
100
Фаза
- Непригодный
Контакты и местонахождение
В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.
Места учебы
-
-
-
Athens, Греция, 11521
- First Cardiology Department, Hippokration General Hospital
-
-
Критерии участия
Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.
Критерии приемлемости
Возраст, подходящий для обучения
- Взрослый
- Пожилой взрослый
Принимает здоровых добровольцев
Нет
Описание
Inclusion Criteria:
- patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy
- patients undergoing M-TEER as a bridge to heart transplantation
Exclusion Criteria:
- Patients with post-procedural transmitral gradient ≥5 mmHg,
- Patients with right-to-left shunt requiring iASD closure,
- Patients, who decline to provide written informed consent.
Учебный план
В этом разделе представлена подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.
Как устроено исследование?
Детали дизайна
- Основная цель: Диагностика
- Распределение: Н/Д
- Интервенционная модель: Одногрупповое задание
- Маскировка: Нет (открытая этикетка)
Оружие и интервенции
Группа участников / Армия |
Вмешательство/лечение |
|---|---|
|
Другой: M-TEER patients
high- or prohibitive-surgical-risk patients with severe mitral regurgitation
|
Hemodynamic and echocardiographic assessment of M-TEER procedural success
|
Что измеряет исследование?
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER
Временное ограничение: The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
|
|
the cut-off point of iASD gradient for identifying mild or trivial mitral regurgitation after M-TEER procedure
Временное ограничение: 4 years
|
To determine the cut-off point of the post-procedural iASD gradient for identifying mild or trivial residual mitral regurgitation after M-TEER procedure
|
4 years
|
Соавторы и исследователи
Здесь вы найдете людей и организации, участвующие в этом исследовании.
Спонсор
Публикации и полезные ссылки
Лицо, ответственное за внесение сведений об исследовании, добровольно предоставляет эти публикации. Это может быть что угодно, связанное с исследованием.
Общие публикации
- Sakul S, DiazSaravia S, Berman B, Dominguez AC, Lerakis S, Argulian E. "Echo-derived estimate of peak left atrial pressure in patients with iatrogenic atrial septal defects following transcatheter mitral edge-to-edge repair". Int J Cardiol. 2026 Feb 1;444:133975. doi: 10.1016/j.ijcard.2025.133975. Epub 2025 Oct 25.
- Zoghbi WA, Asch FM, Bruce C, Gillam LD, Grayburn PA, Hahn RT, Inglessis I, Islam AM, Lerakis S, Little SH, Siegel RJ, Skubas N, Slesnick TC, Stewart WJ, Thavendiranathan P, Weissman NJ, Yasukochi S, Zimmerman KG. Guidelines for the Evaluation of Valvular Regurgitation After Percutaneous Valve Repair or Replacement: A Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Angiography and Interventions, Japanese Society of Echocardiography, and Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr. 2019 Apr;32(4):431-475. doi: 10.1016/j.echo.2019.01.003. Epub 2019 Feb 20. No abstract available.
- Little SH, Quader N, Brady M, Dillenbeck A, Garcia-Sayan E, Jain R, Mackensen GB, Price MJ, Saric M, Scalia GM, Wang DD, Hahn RT. Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2026 Jun;39(6):529-550. doi: 10.1016/j.echo.2026.03.003.
Даты записи исследования
Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.
Изучение основных дат
Начало исследования (Действительный)
9 сентября 2024 г.
Первичное завершение (Оцененный)
10 июня 2028 г.
Завершение исследования (Оцененный)
10 июня 2028 г.
Даты регистрации исследования
Первый отправленный
11 июля 2026 г.
Впервые представлено, что соответствует критериям контроля качества
29 августа 2026 г.
Первый опубликованный (Действительный)
1 сентября 2026 г.
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
1 сентября 2026 г.
Последнее отправленное обновление, отвечающее критериям контроля качества
29 августа 2026 г.
Последняя проверка
1 августа 2026 г.
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
- 22532/19-12-2023
Планирование данных отдельных участников (IPD)
Планируете делиться данными об отдельных участниках (IPD)?
НЕ РЕШЕНО
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Нет
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
Нет
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .