Iatrogenic Atrial Septal Defect Gradient for Intraprocedural Success After M-teer (IASIS)
29 sierpnia 2026 zaktualizowane przez: Konstantinos Tsioufis, Hippocration General Hospital
Iatrogenic ASD Gradient as a Marker of Residual Mitral Regurgitation Severity After M-TEER Procedure
Transcatheter mitral edge-to-edge repair (M-TEER) has become an established minimally invasive therapy for patients with severe mitral regurgitation (MR) who are at high or prohibitive surgical risk.
However, accurate quantification of residual MR after M-TEER remains challenging.
In this direction, the hemodynamic significance of the post-procedural iatrogenic atrial septal defect (iASD) gradient is unknown.
The objective of this study is to assess the relationship between the post-procedural iASD pressure gradient and the severity of residual MR with intraprocedural echocardiographic and hemodynamic parameters.
Przegląd badań
Status
Aktywny, nie rekrutujący
Interwencja / Leczenie
Szczegółowy opis
The present study plans to enroll patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy.
Patients with severe tricuspid regurgitation, post-procedural transmitral gradient >5 mmHg, right-to-left shunt requiring iASD closure, or refusal to provide written informed consent will be excluded.
All intraoperative transesophageal echo loops will be acquired using an EPIQ ultrasound system (Philips, Eindhoven, Netherlands) with an X8-2t transesophageal probe.
At the end of the procedure, in the mid-esophageal aortic valve short-axis view, flow across the iASD will be assessed immediately after catheter withdrawal from the left atrium using continuous-wave Doppler interrogation.
Through a cardiac cycle, the mean pressure gradient between the left and right atria will be calculated while maintaining hemodynamic stability.
Digitally stored image loops will be analyzed offline.
Blinded analysis will be performed by an independent investigator.
For assessment of residual MR, multiplanar reconstruction will be used, and the largest systolic 3D-VCA will be measured.
When multiple regurgitant jets are present, the total regurgitant orifice area will be calculated as the sum of the individual 3D-VCAs.
The primary endpoint is to determine the association and diagnostic performance of the post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER, as assessed by blinded offline 3D-VCA analysis.
Typ studiów
Interwencyjne
Zapisy (Szacowany)
100
Faza
- Nie dotyczy
Kontakty i lokalizacje
Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.
Lokalizacje studiów
-
-
-
Athens, Grecja, 11521
- First Cardiology Department, Hippokration General Hospital
-
-
Kryteria uczestnictwa
Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Nie
Opis
Inclusion Criteria:
- patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy
- patients undergoing M-TEER as a bridge to heart transplantation
Exclusion Criteria:
- Patients with post-procedural transmitral gradient ≥5 mmHg,
- Patients with right-to-left shunt requiring iASD closure,
- Patients, who decline to provide written informed consent.
Plan studiów
Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Diagnostyczny
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Inny: M-TEER patients
high- or prohibitive-surgical-risk patients with severe mitral regurgitation
|
Hemodynamic and echocardiographic assessment of M-TEER procedural success
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER
Ramy czasowe: The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
|
|
the cut-off point of iASD gradient for identifying mild or trivial mitral regurgitation after M-TEER procedure
Ramy czasowe: 4 years
|
To determine the cut-off point of the post-procedural iASD gradient for identifying mild or trivial residual mitral regurgitation after M-TEER procedure
|
4 years
|
Współpracownicy i badacze
Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.
Sponsor
Publikacje i pomocne linki
Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.
Publikacje ogólne
- Sakul S, DiazSaravia S, Berman B, Dominguez AC, Lerakis S, Argulian E. "Echo-derived estimate of peak left atrial pressure in patients with iatrogenic atrial septal defects following transcatheter mitral edge-to-edge repair". Int J Cardiol. 2026 Feb 1;444:133975. doi: 10.1016/j.ijcard.2025.133975. Epub 2025 Oct 25.
- Zoghbi WA, Asch FM, Bruce C, Gillam LD, Grayburn PA, Hahn RT, Inglessis I, Islam AM, Lerakis S, Little SH, Siegel RJ, Skubas N, Slesnick TC, Stewart WJ, Thavendiranathan P, Weissman NJ, Yasukochi S, Zimmerman KG. Guidelines for the Evaluation of Valvular Regurgitation After Percutaneous Valve Repair or Replacement: A Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Angiography and Interventions, Japanese Society of Echocardiography, and Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr. 2019 Apr;32(4):431-475. doi: 10.1016/j.echo.2019.01.003. Epub 2019 Feb 20. No abstract available.
- Little SH, Quader N, Brady M, Dillenbeck A, Garcia-Sayan E, Jain R, Mackensen GB, Price MJ, Saric M, Scalia GM, Wang DD, Hahn RT. Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2026 Jun;39(6):529-550. doi: 10.1016/j.echo.2026.03.003.
Daty zapisu na studia
Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
9 września 2024
Zakończenie podstawowe (Szacowany)
10 czerwca 2028
Ukończenie studiów (Szacowany)
10 czerwca 2028
Daty rejestracji na studia
Pierwszy przesłany
11 lipca 2026
Pierwszy przesłany, który spełnia kryteria kontroli jakości
29 sierpnia 2026
Pierwszy wysłany (Rzeczywisty)
1 września 2026
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
1 września 2026
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
29 sierpnia 2026
Ostatnia weryfikacja
1 sierpnia 2026
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- 22532/19-12-2023
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
NIEZDECYDOWANY
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Nie
Bada produkt urządzenia regulowany przez amerykańską FDA
Nie
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .