Iatrogenic Atrial Septal Defect Gradient for Intraprocedural Success After M-teer (IASIS)
2026. augusztus 29. frissítette: Konstantinos Tsioufis, Hippocration General Hospital
Iatrogenic ASD Gradient as a Marker of Residual Mitral Regurgitation Severity After M-TEER Procedure
Transcatheter mitral edge-to-edge repair (M-TEER) has become an established minimally invasive therapy for patients with severe mitral regurgitation (MR) who are at high or prohibitive surgical risk.
However, accurate quantification of residual MR after M-TEER remains challenging.
In this direction, the hemodynamic significance of the post-procedural iatrogenic atrial septal defect (iASD) gradient is unknown.
The objective of this study is to assess the relationship between the post-procedural iASD pressure gradient and the severity of residual MR with intraprocedural echocardiographic and hemodynamic parameters.
A tanulmány áttekintése
Állapot
Aktív, nem toborzó
Körülmények
Beavatkozás / kezelés
Részletes leírás
The present study plans to enroll patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy.
Patients with severe tricuspid regurgitation, post-procedural transmitral gradient >5 mmHg, right-to-left shunt requiring iASD closure, or refusal to provide written informed consent will be excluded.
All intraoperative transesophageal echo loops will be acquired using an EPIQ ultrasound system (Philips, Eindhoven, Netherlands) with an X8-2t transesophageal probe.
At the end of the procedure, in the mid-esophageal aortic valve short-axis view, flow across the iASD will be assessed immediately after catheter withdrawal from the left atrium using continuous-wave Doppler interrogation.
Through a cardiac cycle, the mean pressure gradient between the left and right atria will be calculated while maintaining hemodynamic stability.
Digitally stored image loops will be analyzed offline.
Blinded analysis will be performed by an independent investigator.
For assessment of residual MR, multiplanar reconstruction will be used, and the largest systolic 3D-VCA will be measured.
When multiple regurgitant jets are present, the total regurgitant orifice area will be calculated as the sum of the individual 3D-VCAs.
The primary endpoint is to determine the association and diagnostic performance of the post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER, as assessed by blinded offline 3D-VCA analysis.
Tanulmány típusa
Beavatkozó
Beiratkozás (Becsült)
100
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.
Tanulmányi helyek
-
-
-
Athens, Görögország, 11521
- First Cardiology Department, Hippokration General Hospital
-
-
Részvételi kritériumok
A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.
Jogosultsági kritériumok
Tanulmányozható életkorok
- Felnőtt
- Idősebb felnőtt
Egészséges önkénteseket fogad
Nem
Leírás
Inclusion Criteria:
- patients with high or prohibitive surgical risk and moderate-to-severe or severe symptomatic MR, despite the administration of maximally tolerated doses of guideline-directed medical therapy and, if appropriate, cardiac resynchronization therapy
- patients undergoing M-TEER as a bridge to heart transplantation
Exclusion Criteria:
- Patients with post-procedural transmitral gradient ≥5 mmHg,
- Patients with right-to-left shunt requiring iASD closure,
- Patients, who decline to provide written informed consent.
Tanulási terv
Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Diagnosztikai
- Kiosztás: N/A
- Beavatkozó modell: Egyetlen csoportos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Egyéb: M-TEER patients
high- or prohibitive-surgical-risk patients with severe mitral regurgitation
|
Hemodynamic and echocardiographic assessment of M-TEER procedural success
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
post-procedural mean left-to-right iASD pressure gradient, measured immediately after catheter withdrawal, for identifying moderate-or-greater residual mitral regurgitation after M-TEER
Időkeret: The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
The iASD gradient, echocardiographic and hemodynamic markers of procedural success will be assessed immediately after catheter withdrawal at the end of the M-TEER procedure.
|
|
|
the cut-off point of iASD gradient for identifying mild or trivial mitral regurgitation after M-TEER procedure
Időkeret: 4 years
|
To determine the cut-off point of the post-procedural iASD gradient for identifying mild or trivial residual mitral regurgitation after M-TEER procedure
|
4 years
|
Együttműködők és nyomozók
Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.
Szponzor
Publikációk és hasznos linkek
A vizsgálattal kapcsolatos információk beviteléért felelős személy önkéntesen bocsátja rendelkezésre ezeket a kiadványokat. Ezek bármiről szólhatnak, ami a tanulmányhoz kapcsolódik.
Általános kiadványok
- Sakul S, DiazSaravia S, Berman B, Dominguez AC, Lerakis S, Argulian E. "Echo-derived estimate of peak left atrial pressure in patients with iatrogenic atrial septal defects following transcatheter mitral edge-to-edge repair". Int J Cardiol. 2026 Feb 1;444:133975. doi: 10.1016/j.ijcard.2025.133975. Epub 2025 Oct 25.
- Zoghbi WA, Asch FM, Bruce C, Gillam LD, Grayburn PA, Hahn RT, Inglessis I, Islam AM, Lerakis S, Little SH, Siegel RJ, Skubas N, Slesnick TC, Stewart WJ, Thavendiranathan P, Weissman NJ, Yasukochi S, Zimmerman KG. Guidelines for the Evaluation of Valvular Regurgitation After Percutaneous Valve Repair or Replacement: A Report from the American Society of Echocardiography Developed in Collaboration with the Society for Cardiovascular Angiography and Interventions, Japanese Society of Echocardiography, and Society for Cardiovascular Magnetic Resonance. J Am Soc Echocardiogr. 2019 Apr;32(4):431-475. doi: 10.1016/j.echo.2019.01.003. Epub 2019 Feb 20. No abstract available.
- Little SH, Quader N, Brady M, Dillenbeck A, Garcia-Sayan E, Jain R, Mackensen GB, Price MJ, Saric M, Scalia GM, Wang DD, Hahn RT. Guidelines for the Intraprocedural Imaging for Mitral Valve Transcatheter Edge-to-Edge Repair (M-TEER): Recommendations from the American Society of Echocardiography. J Am Soc Echocardiogr. 2026 Jun;39(6):529-550. doi: 10.1016/j.echo.2026.03.003.
Tanulmányi rekorddátumok
Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
2024. szeptember 9.
Elsődleges befejezés (Becsült)
2028. június 10.
A tanulmány befejezése (Becsült)
2028. június 10.
Tanulmányi regisztráció dátumai
Először benyújtva
2026. július 11.
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
2026. augusztus 29.
Első közzététel (Tényleges)
2026. szeptember 1.
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
2026. szeptember 1.
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
2026. augusztus 29.
Utolsó ellenőrzés
2026. augusztus 1.
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- 22532/19-12-2023
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
ELDÖNTETLEN
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Nem
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Nem
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .