Comparison of a single high-sensitivity cardiac troponin T measurement with the HEART score for rapid rule-out of acute myocardial infarction in a primary care emergency setting: a cohort study

Tonje R Johannessen, Dan Atar, Odd Martin Vallersnes, Anne Cecilie K Larstorp, Ibrahimu Mdala, Sigrun Halvorsen, Tonje R Johannessen, Dan Atar, Odd Martin Vallersnes, Anne Cecilie K Larstorp, Ibrahimu Mdala, Sigrun Halvorsen

Abstract

Objective: This study aims to compare the rule-out safety of a single high-sensitivity cardiac troponin T (hs-cTnT) with the History, ECG, Age, Risk factors and Troponin (HEART) score in a low-prevalence primary care setting of acute myocardial infarction (AMI).

Participants: Patients with non-specific symptoms suggestive of AMI were consecutively enroled at a primary care emergency clinic in Oslo, Norway from November 2016 to October 2018.

Methods: After initial assessment by a general practitioner, hs-cTnT samples were drawn. AMI was ruled-out by a single hs-cTnT <5 ng/L measured ≥3 hours after symptom onset. The HEART score was calculated retrospectively; a score ≤3 of 10 points was considered low risk. We also calculated a modified HEART score using more sensitive hs-cTnT thresholds. The primary outcome was the diagnostic performance for the rule-out of AMI at the index event; the secondary the composite of AMI or all-cause death at 90 days.

Results: Among 1711 patients, 61 (3.6%) were diagnosed with AMI, and 569 (33.3%) patients were assigned to single rule-out (<5 ng/L). With no AMIs in this group, the negative predictive value (NPV) and sensitivity were both 100.0% (95% CI 99.4% to 100.0% and 94.1% to 100.0%, respectively), and the specificity 34.5% (32.2% to 36.8%). The original HEART score triaged more patients as low risk (n=871), but missed five AMIs (NPV 99.4% (98.7% to 99.8%); sensitivity 91.8% (81.9% to 97.3%) and specificity 52.5% (50.0% to 54.9%)). The modified HEART score increased the low-risk sensitivity to 98.4% (91.2% to 100.0%), with specificity 38.7% (36.3% to 41.1%). The 90-day incidence of AMI or death in the single rule-out and the original and modified low-risk HEART groups were 0.0%, 0.7%, and 0.2%, respectively.

Conclusion: In a primary care emergency setting, a single hs-cTnT strategy was superior to the HEART score in ruling out AMI. This rapid and safe approach may enhance the assessment of patients with chest pain outside of hospitals.

Trial registration number: NCT02983123.

Keywords: accident & emergency medicine; coronary heart disease; ischaemic heart disease; myocardial infarction; primary care.

Conflict of interest statement

Competing interests: None declared.

© Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

Figures

Figure 1
Figure 1
Patient flow chart. Study enrolment at the primary care emergency clinic during the OUT-ACS study. *Critically ill patients are brought directly to hospital by the ambulance services. ACS, acute coronary syndrome; hs-cTnT, high-sensitivity cardiac troponin T; OAEOC, Oslo Accident and Emergency Outpatient Clinic; OUT-ACS, One hoUr Troponin in a low-prevalence population of Acute Coronary Syndrome.
Figure 2
Figure 2
The diagnostic and prognostic safety of the three rule-out strategies at the primary care emergency clinic. AMI, acute myocardial infarction; HEART, History, ECG, Age, Risk factors and Troponin; hs-cTnT, high-sensitivity cardiac troponin T; NPV, negative predictive value; NSTE-ACS, non-ST-segment elevation acute coronary syndrome.
Figure 3
Figure 3
The overall diagnostic performance of the single hs-cTnT strategy, the original HEART score and the modified HEART score were illustrated by the AUC, which was achieved using the predefined cut-off values for the three different strategies. The single hs-cTnT rule-in and high-risk HEART groups are shown in the lower-left corner, the single hs-cTnT rule-out and low-risk HEART groups in the upper right. The large intermediate groups represent the patients in need of further tests. AUC, area under the curve; HEART, History, ECG, Age, Risk factors and Troponin; hs-cTnT, high-sensitivity cardiac troponin T.

References

    1. Thygesen K, Alpert JS, Jaffe AS, et al. . Third universal definition of myocardial infarction. J Am Coll Cardiol 2012;60:1581–98. 10.1016/j.jacc.2012.08.001
    1. Collet J-P, Thiele H, Barbato E, et al. . 2020 ESC guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation. Eur Heart J 2020:ehaa575. 10.1093/eurheartj/ehaa575
    1. Burman RA, Zakariassen E, Hunskaar S. Management of chest pain: a prospective study from Norwegian out-of-hours primary care. BMC Fam Pract 2014;15:51. 10.1186/1471-2296-15-51
    1. Hoorweg BB, Willemsen RT, Cleef LE, et al. . Frequency of chest pain in primary care, diagnostic tests performed and final diagnoses. Heart 2017;103:1727–32. 10.1136/heartjnl-2016-310905
    1. Harskamp RE, Laeven SC, Himmelreich JC, et al. . Chest pain in general practice: a systematic review of prediction rules. BMJ Open 2019;9:e027081. 10.1136/bmjopen-2018-027081
    1. Nilsson S, Andersson PO, Borgquist L, et al. . Point-of-care troponin T testing in the management of patients with chest pain in the Swedish primary care. Int J Family Med 2013;2013:1–7. 10.1155/2013/532093
    1. Schols AMR, Stakenborg JPG, Dinant G-J, et al. . Point-of-care testing in primary care patients with acute cardiopulmonary symptoms: a systematic review. Fam Pract 2018;35:4–12. 10.1093/fampra/cmx066
    1. Rasmussen MB, Stengaard C, Sørensen JT, et al. . Predictive value of routine point-of-care cardiac troponin T measurement for prehospital diagnosis and risk-stratification in patients with suspected acute myocardial infarction. Eur Heart J Acute Cardiovasc Care 2019;8:299–308. 10.1177/2048872617745893
    1. Stopyra JP, Snavely AC, Scheidler JF, et al. . Point-of-Care troponin testing during ambulance transport to detect acute myocardial infarction. Prehospital Emergency Care 2020;24:751–9. 10.1080/10903127.2020.1721740
    1. Alghamdi A, Alotaibi A, Alharbi M, et al. . Diagnostic performance of prehospital point-of-care troponin tests to rule out acute myocardial infarction: a systematic review. Prehosp Disaster Med 2020;35:567–73. 10.1017/S1049023X20000850
    1. Six AJ, Backus BE, Kelder JC. Chest pain in the emergency room: value of the heart score. Neth Heart J 2008;16:191–6. 10.1007/BF03086144
    1. Backus BE, Six AJ, Kelder JC, et al. . A prospective validation of the heart score for chest pain patients at the emergency department. Int J Cardiol 2013;168:2153–8. 10.1016/j.ijcard.2013.01.255
    1. Ishak M, Ali D, Fokkert MJ, et al. . Fast assessment and management of chest pain patients without ST-elevation in the pre-hospital gateway (famous triage): ruling out a myocardial infarction at home with the modified heart score. Eur Heart J Acute Cardiovasc Care 2018;7:102–10. 10.1177/2048872616687116
    1. van Dongen DN, Tolsma RT, Fokkert MJ, et al. . Pre-hospital risk assessment in suspected non-ST-elevation acute coronary syndrome: a prospective observational study. Eur Heart J Acute Cardiovasc Care 2020;9:5-12. 10.1177/2048872618813846
    1. McCord J, Cabrera R, Lindahl B, et al. . Prognostic utility of a modified heart score in chest pain patients in the emergency department. Circ Cardiovasc Qual Outcomes 2017;10. 10.1161/CIRCOUTCOMES.116.003101
    1. Santi L, Farina G, Gramenzi A, et al. . The heart score with high-sensitive troponin T at presentation: ruling out patients with chest pain in the emergency room. Intern Emerg Med 2017;12:357–64. 10.1007/s11739-016-1461-3
    1. Sörensen NA, Neumann JT, Ojeda F, et al. . Diagnostic evaluation of a high-sensitivity troponin I point-of-care assay. Clin Chem 2019;65:1592–601. 10.1373/clinchem.2019.307405
    1. Boeddinghaus J, Nestelberger T, Koechlin L, et al. . Early diagnosis of myocardial infarction with point-of-care high-sensitivity cardiac troponin I. J Am Coll Cardiol 2020;75:1111–24. 10.1016/j.jacc.2019.12.065
    1. Johannessen TR, Vallersnes OM, Halvorsen S, et al. . Pre-hospital one-hour troponin in a low-prevalence population of acute coronary syndrome: OUT-ACS study. Open Heart 2020;7:e001296. 10.1136/openhrt-2020-001296
    1. Marshall GA, Wijeratne NG, Thomas D. Should general practitioners order troponin tests? Med J Aust 2014;201:155–7. 10.5694/mja13.00173
    1. Zhelev Z, Hyde C, Youngman E, et al. . Diagnostic accuracy of single baseline measurement of Elecsys troponin T high-sensitive assay for diagnosis of acute myocardial infarction in emergency department: systematic review and meta-analysis. BMJ 2015;350:h15. 10.1136/bmj.h15
    1. Pickering JW, Than MP, Cullen L, et al. . Rapid rule-out of acute myocardial infarction with a single high-sensitivity cardiac troponin T measurement below the limit of detection: a collaborative meta-analysis. Ann Intern Med 2017;166:715–24. 10.7326/M16-2562
    1. Giannitsis E, Kurz K, Hallermayer K, et al. . Analytical validation of a high-sensitivity cardiac troponin T assay. Clin Chem 2010;56:254–61. 10.1373/clinchem.2009.132654
    1. Body R, Morris N, Reynard C, et al. . Comparison of four decision aids for the early diagnosis of acute coronary syndromes in the emergency department. Emerg Med J 2020;37:8–13. 10.1136/emermed-2019-208898
    1. Norwegian Institute of Public Health . Norwegian Cardiovascular Disease Registry, 2012. Available: [Accessed 23 Mar 2020].
    1. Bossuyt PM, Reitsma JB, Bruns DE, et al. . STARD 2015: an updated list of essential items for reporting diagnostic accuracy studies. BMJ 2015;351:h5527. 10.1136/bmj.h5527
    1. Mark DG, Huang J, Kennedy CJ, et al. . 60-day major adverse cardiac events in emergency department patients with non-low modified heart scores. Am J Emerg Med 2020;38:2760.e5–2760.e8. 10.1016/j.ajem.2020.05.081
    1. Chew PG, Frost F, Mullen L, et al. . A direct comparison of decision rules for early discharge of suspected acute coronary syndromes in the era of high sensitivity troponin. Eur Heart J Acute Cardiovasc Care 2019;8:421–31. 10.1177/2048872618755369
    1. Sanchis J, Valero E, García Blas S, et al. . Undetectable high-sensitivity troponin in combination with clinical assessment for risk stratification of patients with chest pain and normal troponin at hospital arrival. Eur Heart J Acute Cardiovasc Care 2020;9:567–75. 10.1177/2048872620907539
    1. Chapman AR, Hesse K, Andrews J, et al. . High-sensitivity cardiac troponin I and clinical risk scores in patients with suspected acute coronary syndrome. Circulation 2018;138:1654–65. 10.1161/CIRCULATIONAHA.118.036426
    1. van Dongen DN, Ottervanger JP, Tolsma R, et al. . In-hospital healthcare utilization, outcomes, and costs in Pre-Hospital-Adjudicated low-risk chest-pain patients. Appl Health Econ Health Policy 2019;17:875–82. 10.1007/s40258-019-00502-6
    1. Marchick MR, Setteducato ML, Revenis JJ, et al. . Comparison of 3 symptom classification methods to standardize the history component of the heart score. Crit Pathw Cardiol 2017;16:102–4. 10.1097/HPC.0000000000000119

Source: PubMed

3