Digital model as an alternative to plaster model in assessment of space analysis

A Anand Kumar, Abraham Phillip, Sathesh Kumar, Anuradha Rawat, Sakthi Priya, V Kumaran, A Anand Kumar, Abraham Phillip, Sathesh Kumar, Anuradha Rawat, Sakthi Priya, V Kumaran

Abstract

Introduction: Digital three-dimensional models are widely used for orthodontic diagnosis. The purpose of this study was to appraise the accuracy of digital models obtained from computer-aided design/computer-aided manufacturing (CAD/CAM) and cone-beam computed tomography (CBCT) for tooth-width measurements and the Bolton analysis.

Materials and methods: Digital models (CAD/CAM, CBCT) and plaster model were made for each of 50 subjects. Tooth-width measurements on the digital models (CAD/CAM, CBCT) were compared with those on the corresponding plaster models. The anterior and overall Bolton ratios were calculated for each participant and for each method. The paired t-test was applied to determine the validity.

Results: Tooth-width measurements, anterior, and overall Bolton ratio of digital models of CAD/CAM and CBCT did not differ significantly from those on the plaster models.

Conclusion: Hence, both CBCT and CAD/CAM are trustable and promising technique that can replace plaster models due to its overwhelming advantages.

Keywords: Bolton's ratio; Computer-aided design/computer-aided manufacturing; cone-beam computed tomography; digital models.

Figures

Graph 1
Graph 1
The comparison of anterior Bolton's ratio calculated from computer-aided design/computer-aided manufacturing, cone-beam computed tomography, and plaster model measurements
Graph 2
Graph 2
The comparison of overall Bolton's ratio calculated from computer-aided design/computer-aided manufacturing, cone-beam computed tomography, and plaster model measurements

References

    1. Nakajima A, Murata M, Tanaka E, Arai Y, Fukase Y, Nishi Y, et al. Development of three-dimensional FE modeling system from the limited cone beam CT images for orthodontic tipping tooth movement. Dent Mater J. 2007;26:882–91.
    1. Ghoneima A, Allam E, Kula K, Windsor LJ. Three-dimensional imaging and software advances in orthodontics. Orthod Basic Asp Clin Considerations. 2012;9:200–39.
    1. Shelhart WC, Lange W, Kaplen AL, Kulemper GT. Reliability of Boltontooth size when applied to crowded dentition. Angle orthodontics. 2005;65:327–334.
    1. Mörmann WH. The evolution of the CEREC system. J Am Dent Assoc. 2006;137(suppl):7S–13S.
    1. Benz C, Schwarz P. How precise is the optical CEREC impression? [in German] DtschZahnarztl Z. 1991;46:632–634.
    1. Bolton WA. Disharmony in tooth size and its relation to the analysis and treatment of malocclusion. Angle Orthod. 1958;28:113–30.
    1. Mayers M, Firestone AR, Rashid R, Vig KW. Comparison of peer assessment rating (PAR) index scores of plaster and computer-based digital models. Am J Orthod Dentofacial Orthop. 2005;128:431–4.
    1. Ye N, Jian F, Xue J, Wang S, Liao L, Huang W, Yang X, Zhou Y, Lai AW, Wang JLJ. Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography. Am J Orthod Dentofacial Orthop. 2012;142:879–887.
    1. Tarazona B, Llamas JM, Cibrián R, Gandía JL, Paredes V. Evaluation of the validity of the Bolton Index using cone-beam computed tomography (CBCT) Med Oral Patol Oral Cir Bucal. 2012;17:e878–83.
    1. Asquith J, Gillgrass T, Mossey P. Three-dimensional imaging of orthodontic models: A pilot study. Eur J Orthod. 2007;29:517–22.
    1. Zilberman O, Huggare JAV, Parikakis KA. Evaluation of the validity of tooth size and arch width measurements using conventional and three-dimensional virtual models. Angle Orthod. 2003;73:301–6.
    1. Hunter WS, Priest WR. Errors and discrepancies in measurement of tooth size. Journal of Dental Research. 1960;39:405–14.
    1. White AJ, Fallis DW, Vandewalle KS. Analysis of intra-arch and interarch measurements from digital models with 2 impression materials and a modeling process based on cone-beam computed tomography. Am J Orthod Dentofacial Orthop. 2010;137:456.e1–9.
    1. Stevens DR, Flores-Mir C, Nebbe B, Raboud DW, Heo G, Major PW. Validity, reliability, and reproducibility of plaster vs digital study models: Comparison of peer assessment rating and Bolton analysis and their constituent measurements. Am J Orthod Dentofacial Orthop. 2006;129:794–803.
    1. Leifert MF, Leifert MM, Efstratiadis SS, Cangialosi TJ. Comparison of space analysis evaluations with digital models and plaster dental casts. Am J Orthod Dentofacial Orthop. 2009;136:16.e1–16.e4.
    1. Wiranto MG, Engelbrecht WP, Nolthenius HET, van der Meer WJ, Ren Y. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions. Am J Orthod Dentofacial Orthop. 2013;143:140–7.
    1. Brown AA, Scarfe WC, Scheetz JP, Silveira AM, Farman AG. Linear accuracy of cone beam CT derived 3D images. Angle Orthod. 2009;79:150–7.