Abstract

Objective: To investigate the reliability of the 50-Foot Walk Test (50 FWT) and 30-second Chair Stand Test (30 CST) in patients who have undergone total knee arthroplasty (TKA).

Methods: The study was designed as a test-retest research. Thirty-three patients who would undergo bilateral TKA were recruited. The tests 30 CST and 50 FWT were performed twice on the same day with 5-minute intervals, respectively. Between the first and second tests, patients waited for an hour on sitting position in order to prevent fatigue. In addition to these tests, we registered the knee pain experienced by the patients using a 100 mm VAS scale.

Results: The 50 FWT and 30 CST showed excellent reliability. ICC for 50 FWT and 30 CST were 0.97 and 0.92, respectively. SRD95 was 1.07 for 50 FWT and 0.96 for 30 CST.

Conclusions: According to results of this study, both 50 FWT and 30 CST have excellent reliability in patients with TKA. These tests are simple, no time consuming and constitute sensitive methods to measure the functional performance in patients with TKA in the clinical settings. Clinicians and researchers may use these tests to quantify even small changes in functional performance for patients with TKA. Level of Evidence III, Diagnostic Study.

Keywords: Arthroplasty; Knee; Performance tests; Rehabilitation; Replacement.

Conflict of interest statement

All the authors declare that there is no potential conflict of interest referring to this article.

References

    1. Davies GM, Watson DJ, Bellamy N. Comparison of the responsiveness and relative effect size of the Western Ontario and McMaster Universities Osteoarthritis Index and the short-form medical outcomes study survey in a randomized, clinical trial of osteoarthritis patients. Arthritis Care Res. 1999;3:172–179.
    1. Gill S, McBurney H. Reliability of performance-based measures in people awaiting joint replacement surgery of the hip or knee. Physiother Res Int. 2008;13(3):141–152.
    1. Guyatt G, Walter S, Norman G. Measuring change over time: assessing the usefulness of evaluative instruments. J Chronic Dis. 1987;2:171–178.
    1. Husted JA, Cook RJ, Farewell VT, Gladman DD. Methods for assessing responsiveness: a critical review and recommendations. J Clin Epidemiol. 2000;53(5):459–468.
    1. Jones CJ, Rikli RE, Beam WC. A 30-s chair-stand test as a measure of lower body strength in community-residing older adults. Res Q Exerc Sport. 1999;70(2):113–119.
    1. Tekin B, Unver B, Karatosun V. Expectations in patients with total knee arthroplasty. Acta Orthop Traumatol Turc. 2012;46(3):174–180.
    1. Dobson F, Hinman RS, Roos EM, Abbott JH, Stratford P, Davis AM. OARSI recommended performance-based tests to assess physical function in people diagnosed with hip or knee osteoarthritis. Osteoarthritis Cartilage. 2013;21(8):1042–1052.
    1. Unver B, Karatosun V, Bakirhan S. Ability to rise independently from a chair during 6-month follow-up after unilateral and bilateral total knee replacement. J Rehabil Med. 2005;37(6):385–387.
    1. Weiss JM, Noble PC, Conditt MA, Kohl HW, Roberts S, Cook KF. What functional activities are important to patients with knee replacements. Clin Orthop Relat Res. 2002;(404):172–188.
    1. Kennedy DM, Stratford PW, Wessel J, Gollish JD, Penney D. Assessing stability and change of four performance measures: a longitudinal study evaluating outcome following total hip and knee arthroplasty. BMC Musculoskelet Disord. 2005;28;6:3–3.
    1. van den Dikkenberg N, Meijer OG, van der Slikke RM, van Lummel RC, van ieën JH, Pijls B. Measuring functional abilities of patientswith knee problems: rationale and construction of the DynaPort knee test. Knee Surg Sports Traumatol Arthrosc. 2002;10(4):204–212.
    1. Unver B, Kahraman T, Kalkan S, Yuksel E, Karatosun V. Reliability of the six-minute walk test after total hip arthroplasty. Hip Int. 2013;23(6):541–545.
    1. Unnanuntana A, Mait JE, Shaffer AD, Lane JM, Mancuso CA. Performance-based tests and self-reported questionnaires provide distinct information for the preoperative evaluation of total hip arthroplasty patients. J Arthroplasty. 2012;27(5):770–775.
    1. Narin S, Unver B, Bakirhan S, Bozan O, Karatosun V. Cross-cultural adaptation, reliability and validity of the Turkish version of the Hospital for Special Surgery (HSS) Knee Score. Acta Orthop Traumatol Turc. 2014;48(3):241–248.
    1. Grace EM, Gerecz EM, Kassam YB, Buchanan HM, Buchanan WW, Tugwell PS. 50-foot walking time: a critical assessment of an outcome measure in clinical therapeutic trials of antirheumatic drugs. Br J Rheumatol. 1988;27(5):372–374.
    1. Macfarlane DJ, Chou KL, Cheng YH, Chi I. Validity and normative data for thirty-second chair stand test in elderly community-dwelling Hong Kong Chinese. Am J Hum Biol. 2006;18(3):418–421.
    1. Schilke JM, Johnson GO, Housh TJ, O'Dell JR. Effects of muscle-strength training on the functional status of patients with osteoarthritis of the knee joint. Nurs Res. 1996;45(2):68–72.
    1. Mahoney OM, McClung CD, dela Rosa MA, Schmalzried TP. The effect of total knee arthroplasty design on extensor mechanism function. J Arthroplasty. 2002;17(4):416–421.
    1. Hopkins WG. Measures of reliability in sports medicine and science. Sports Med. 2000;30(1):1–15.
    1. Almeida GJ, Schroeder CA, Gil AB, Fitzgerald GK, Piva SR. Interrater reliability and validity of the stair ascend/descend test in subjects with total knee arthroplasty. Arch Phys Med Rehabil. 2010;91(6):932–938.

Source: PubMed

3
Prenumerera