Robotic-arm assisted total knee arthroplasty is associated with improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based total knee arthroplasty: a prospective cohort study

B Kayani, S Konan, J Tahmassebi, J R T Pietrzak, F S Haddad, B Kayani, S Konan, J Tahmassebi, J R T Pietrzak, F S Haddad

Abstract

Aims: The objective of this study was to compare early postoperative functional outcomes and time to hospital discharge between conventional jig-based total knee arthroplasty (TKA) and robotic-arm assisted TKA.

Patients and methods: This prospective cohort study included 40 consecutive patients undergoing conventional jig-based TKA followed by 40 consecutive patients receiving robotic-arm assisted TKA. All surgical procedures were performed by a single surgeon using the medial parapatellar approach with identical implant designs and standardized postoperative inpatient rehabilitation. Inpatient functional outcomes and time to hospital discharge were collected in all study patients.

Results: There were no systematic differences in baseline characteristics between the conventional jig-based TKA and robotic-arm assisted TKA treatment groups with respect to age (p = 0.32), gender (p = 0.50), body mass index (p = 0.17), American Society of Anesthesiologists score (p = 0.88), and preoperative haemoglobin level (p = 0.82). Robotic-arm assisted TKA was associated with reduced postoperative pain (p < 0.001), decreased analgesia requirements (p < 0.001), decreased reduction in postoperative haemoglobin levels (p < 0.001), shorter time to straight leg raise (p < 0.001), decreased number of physiotherapy sessions (p < 0.001) and improved maximum knee flexion at discharge (p < 0.001) compared with conventional jig-based TKA. Median time to hospital discharge in robotic-arm assisted TKA was 77 hours (interquartile range (IQR) 74 to 81) compared with 105 hours (IQR 98 to 126) in conventional jig-based TKA (p < 0.001).

Conclusion: Robotic-arm assisted TKA was associated with decreased pain, improved early functional recovery and reduced time to hospital discharge compared with conventional jig-based TKA. Cite this article: Bone Joint J 2018;100-B:930-7.

Keywords: Arthroplasty; Hospital discharge; Rehabilitation; Robotics; Knee;.

Figures

Fig. 1
Fig. 1
Boxplot showing pain score as measured using the numerical rating scale in conventional jig-based total knee arthroplasty (TKA) versus robotic-arm assisted TKA.
Fig. 2
Fig. 2
Boxplot showing opiate analgesia requirements in conventional jig-based total knee arthroplasty (TKA) versus robotic-arm assisted TKA.
Fig. 3
Fig. 3
Boxplot showing time to be able to perform a straight leg raise (hours) in conventional jig-based total knee arthroplasty (TKA) versus robotic-arm assisted TKA.
Fig. 4
Fig. 4
Boxplot showing maximum knee flexion (°) at discharge in conventional jig-based total knee arthroplasty (TKA) versus robotic-arm assisted TKA.
Fig. 5
Fig. 5
Boxplot showing number of inpatient physiotherapy sessions in conventional jig-based total knee arthroplasty (TKA) versus robotic-arm assisted TKA.
Fig. 6
Fig. 6
Boxplot showing time to hospital discharge (hours) in conventional jig-based total knee arthroplasty (TKA) versus robotic-arm assisted TKA.

References

    1. No authors listed. National Joint Registry for England and Wales. 9th Annual Report, 2012. (date last accessed 22 March 2018).
    1. El Bitar YF, Illingworth KD, Scaife S, Horberg JV, Saleh KJ. Hospital Length of Stay following Primary Total Knee Arthroplasty: Data from the Nationwide Inpatient Sample Database. J Arthroplasty 2015;30:1710–1715.
    1. Gourin CG, Terris DJHistory of Robotic Surgery. In: Faust RA, ed. Robotics in Surgery: History, Current and Future Applications.New York (NY): Nova Science Publishers, Inc., 2007:3-12.
    1. Cobb J, Henckel J, Gomes P, et al. Hands-on robotic unicompartmental knee replacement: a prospective, randomised controlled study of the acrobot system. J Bone Joint Surg [Br] 2006;88-B:188–197.
    1. Dunbar NJ, Roche MW, Park BH, et al. Accuracy of dynamic tactile-guided unicompartmental knee arthroplasty. J Arthroplasty 2012;27:803–808.
    1. Conditt MA, Roche MW. Minimally invasive robotic-arm-guided unicompartmental knee arthroplasty. J Bone Joint Surg [Am] 2009;91-A(Suppl 1):63–68.
    1. Song EK, Seon JK, Park SJ, et al. Simultaneous bilateral total knee arthroplasty with robotic and conventional techniques: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc 2011;19:1069–1076.
    1. Song EK, Seon JK, Yim JH, Netravali NA, Bargar WL. Robotic-assisted TKA reduces postoperative alignment outliers and improves gap balance compared to conventional TKA. Clin Orthop Relat Res 2013;471:118–126.
    1. Mannan A, Vun J, Lodge C, Eyre-Brook A, Jones SIncreased precision of coronal plane outcomes in robotic-assisted total knee arthroplasty: A systematic review and meta-analysis. Surgeon 2018. (Epub ahead of print) PMID: 29439922.
    1. Saklad M. Grading of patients for surgical procedures. Anesthesiol 1941;2:281–284.
    1. Scott CE, Howie CR, MacDonald D, Biant LC. Predicting dissatisfaction following total knee replacement: a prospective study of 1217 patients. J Bone Joint Surg [Br] 2010;92-B:1253–1258.
    1. Kerr HL, Armstrong LA, Beard L, Teichmann D, Mutimer J. Challenges to the orthopaedic arthroplasty enhanced recovery programme. J Perioper Pract 2017;27:15–19.
    1. Husted H, Holm G, Jacobsen S. Predictors of length of stay and patient satisfaction after hip and knee replacement surgery: fast-track experience in 712 patients. Acta Orthop 2008;79:168–173.
    1. Hossain FS, Patel S, Fernandez MA, Konan S, Haddad FS. A performance based patient outcome score for active patients following total knee arthroplasty. Osteoarthritis Cartilage 2013;21:51–59.
    1. Pinto PR, McIntyre T, Ferraro R, Araújo-Soares V, Almeida A. Persistent pain after total knee or hip arthroplasty: differential study of prevalence, nature, and impact. J Pain Res 2013;6:691–703.
    1. Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. , National Joint Registry for England and Wales. The role of pain and function in determining patient satisfaction after total knee replacement: data from the National Joint Registry for England and Wales. J Bone Joint Surg [Br] 2007;89-B:893–900.
    1. Marchand RC, Sodhi N, Khlopas A, et al. Patient Satisfaction Outcomes after Robotic Arm-Assisted Total Knee Arthroplasty: A Short-Term Evaluation. J Knee Surg 2017;30:849–853.
    1. Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt L. Validation study of WOMAC: a health status instrument for measuring clinically important patient-relevant outcomes following total hip or knee arthroplasty in osteoarthritis. . J Orthop Rheumatol 1988;1:95–108.
    1. Siebert W, Mai S, Kober R, Heeckt PF. Technique and first clinical results of robot-assisted total knee replacement. Knee 2002;9:173–180.
    1. Bremer AK, Kalberer F, Pfirrmann CW, Dora C. Soft-tissue changes in hip abductor muscles and tendons after total hip replacement: comparison between the direct anterior and the transgluteal approaches. J Bone Joint Surg [Br] 2011;93-B:886–889.
    1. Berkin PF, Doppelt JD, Kephart CJ, et al. Comparison of minimally invasive direct anterior versus posterior total hip arthroplasty based on inflammation and muscle damage markers. J Bone Joint Surg [Am] 2011;93-A:1392–1398.
    1. Griffin FM, Insall JN, Scuderi GR. Accuracy of soft tissue balancing in total knee arthroplasty. J Arthroplasty 2000;15:970–973.
    1. Whiteside LA. Soft tissue balancing: the knee. J Arthroplasty 2002;17(Suppl 1):23–27.
    1. Lee G- C, Lotke PA. Management of intraoperative medial collateral ligament injury during TKA. Clin Orthop Relat Res 2011;469:64–68.
    1. McNabb DC, Kim RH, Springer BD. Instability after total knee arthroplasty. J Knee Surg 2015;28:97–104.
    1. Khlopas A, Chughtai M, Hampp EL, et al. Robotic-arm assisted total knee arthroplasty demonstrated soft tissue protection. Surg Technol Int 2017;30:441–446.
    1. Park SE, Lee CT. Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty. J Arthroplasty 2007;22:1054–1059.
    1. Mofidi A, Plate JF, Lu B, et al. Assessment of accuracy of robotically assisted unicompartmental arthroplasty. Knee Surg Sports Traumatol Arthrosc 2014;22:1918–1925.
    1. Rodriguez F, Harris S, Jakopec M, et al. Robotic clinical trials of uni-condylar arthroplasty. Int J Med Robot 2005;1:20–28.
    1. Börner M, Wiesel U, Ditzen WClinical experiences with ROBODOC and the Duracon Total Knee. In: Stiehl JB, Konermann W, Haaker RG, eds. Navigation and Robotics in Total Joint and Spine Surgery. Berlin, Germany: Springer-Verlag, 2004:362–366.
    1. Soffin EM, YaDeau JT. Enhanced recovery after surgery for primary hip and knee arthroplasty: a review of the evidence. Br J Anaesth 2016;117(suppl 3)62–72.

Source: PubMed

3
Prenumerera