Role of IgM testing in the diagnosis and post-treatment follow-up of syphilis: a prospective cohort study

Kara K Osbak, Achilleas Tsoumanis, Irith De Baetselier, Marjan Van Esbroek, Hilde Smet, Chris R Kenyon, Tania Crucitti, Kara K Osbak, Achilleas Tsoumanis, Irith De Baetselier, Marjan Van Esbroek, Hilde Smet, Chris R Kenyon, Tania Crucitti

Abstract

Objectives: The diagnosis of repeat syphilis and its follow-up remains challenging. We aimed to investigate if IgM testing may assist in the diagnosis of syphilis reinfection/relapse and its treatment follow-up.

Methods: This substudy was conducted in the context of a syphilis biomarker discovery study (ClinicalTrials.gov Nr: NCT02059525). Sera were collected from 120 individuals with a new diagnosis of syphilis (72 with repeat infections) and 30 syphilis negative controls during a cohort study investigating syphilis biomarkers conducted at a sexually transmitted infection/HIV clinic in Antwerp, Belgium. Syphilis was diagnosed based on a simultaneous positive treponemal and non-treponemal assay result and/or positive serum PCR targeting polA. Specimens collected at visit of diagnosis, and 3 and 6 months post-treatment were tested by two enzyme immunoassays (EIAs), recomWell (Mikrogen; MI) and Euroimmun (EU), to detect anti-treponemal IgM. Baseline specimens were also tested for anti-treponemal IgM using a line immunoassay (LIA) recomLine (MI). Quantitative kinetic decay curves were constructed from the longitudinal quantitative EIA results.

Results: An overall sensitivity for the diagnosis of syphilis of 59.8% (95% CI: 50.3%-68.7%), 75.0% (95% CI: 66.1%-82.3%) and 63.3% (95% CI: 54.8%-72.6%) was obtained for the EU, MI EIAs and MI LIA, respectively. When only considering repeat syphilis, the diagnostic sensitivity decreased to 45.7% (95% CI: 33.9%-58.0%), 63.9% (95% CI: 51.7%-74.6%) and 47.2% (95% CI: 35.5%-59.3%), respectively. IgM seroreverted in most cases 6 months after treatment. Post-treatment IgM concentrations decreased almost 30% faster for initial syphilis compared with repeat infection. The IgM EIAs and IgM LIA agreed from fairly to moderately (Cohen's kappa (κ): 0.36 (EU EIA); κ: 0.53 (MI EIA); κ: 0.40 (MI LIA)) with the diagnosis of syphilis.

Conclusions: IgM detection was not a sensitive method to diagnose syphilis and was even poorer in the diagnosis of syphilis repeat infections.

Keywords: diagnostic microbiology; microbiology; sexual medicine.

Conflict of interest statement

Competing interests: None declared.

© Author(s) (or their employer(s)) 2020. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

Figures

Figure 1
Figure 1
Initial and post-treatment decay curves of recomWell EIA IgM. EIA, enzyme immunoassay.

References

    1. Abara WE, Hess KL, Neblett Fanfair R, et al. . Syphilis trends among men who have sex with men in the United States and Western Europe: a systematic review of trend studies published between 2004 and 2015. PLoS One 2016;11:e0159309. 10.1371/journal.pone.0159309
    1. Jost H, Castro A, Cox D, et al. . A comparison of the analytical level of agreement of nine treponemal assays for syphilis and possible implications for screening algorithms. BMJ Open 2013;3:e003347. 10.1136/bmjopen-2013-003347
    1. Kenyon C, Lynen L, Florence E, et al. . Syphilis reinfections pose problems for syphilis diagnosis in Antwerp, Belgium - 1992 to 2012. Euro Surveill 2014;19:20958. 10.2807/1560-7917.ES2014.19.45.20958
    1. Kenyon C, Osbak KK, Apers L. Repeat syphilis is more likely to be asymptomatic in HIV-infected individuals: a retrospective cohort analysis with important implications for screening. Open Forum Infect Dis 2018;5:ofy096. 10.1093/ofid/ofy096
    1. Kenyon C, Tsoumanis A, Osbak K, et al. . Repeat syphilis has a different immune response compared with initial syphilis: an analysis of biomarker kinetics in two cohorts. Sex Transm Infect 2018;94:180–6. 10.1136/sextrans-2017-053312
    1. Borkhardt HL, Zielinski S. Influence of cardiolipin antibodies on the binding of treponemal specific antibodies in the fluorescence treponemal antibody absorption test and the Treponema pallidum immobilisation test. J Med Microbiol 1997;46:965–72. 10.1099/00222615-46-11-965
    1. Nandwani R, Evans DT. Are you sure it's syphilis? A review of false positive serology. Int J STD AIDS 1995;6:241–8. 10.1177/095646249500600404
    1. Janier M, Hegyi V, Dupin N, et al. . European guideline on the management of syphilis. J Eur Acad Dermatology Venereol 2014;2014:1581–93.
    1. Bosshard PP. Usefulness of IgM-specific enzyme immunoassays for serodiagnosis of syphilis: comparative evaluation of three different assays. J Infect 2013;67:35–42. 10.1016/j.jinf.2013.03.011
    1. Landry ML. Immunoglobulin M for acute infection: true or false? Clin Vaccine Immunol 2016;23:540–5. 10.1128/CVI.00211-16
    1. Pastuszczak M, Kotnis-Gąska A, Jakubowicz B, et al. . Utility of antitreponemal IgM testing in the diagnosis of early and repeat syphilis among HIV-infected and non-infected patients. Int J STD AIDS 2018;29:890–4. 10.1177/0956462418762849
    1. Workowski KA, Berman S. Centers for disease control and prevention (CDC). sexually transmitted diseases treatment guidelines, 2010. MMWR Recomm reports Morb Mortal Wkly report Recomm reports 2010;59:1–110.
    1. French P, Gomberg M, Janier M, et al. . IUSTI: 2008 European guidelines on the management of syphilis. Int J STD AIDS 2009;20:300–9. 10.1258/ijsa.2008.008510
    1. Liu H, Rodes B, Chen CY, et al. . New tests for syphilis: rational design of a PCR method for detection of Treponema pallidum in clinical specimens using unique regions of the DNA polymerase I gene. J Clin Microbiol 2001;39:1941–6. 10.1128/JCM.39.5.1941-1946.2001
    1. Cohen J. A coefficient of agreement for nominal scales. Educ Psychol Meas 1960;20:37–46. 10.1177/001316446002000104
    1. Team RC R: a language and environment for statistical computing 2018.
    1. Baty F, Ritz C, Charles S, et al. . A Toolbox for Nonlinear Regression in R : The Package nlstools. J Stat Softw 2015;66:1–21. 10.18637/jss.v066.i05
    1. Osbak K, Abdellati S, Tsoumanis A, et al. . Evaluation of an automated quantitative latex immunoturbidimetric non-treponemal assay for diagnosis and follow-up of syphilis: a prospective cohort study. J Med Microbiol 2017;66:1130–9. 10.1099/jmm.0.000559
    1. Martins TB, Jaskowski TD, Mouritsen CL, et al. . An evaluation of the effectiveness of three immunoglobulin G (IgG) removal procedures for routine IgM serological testing. Clin Diagn Lab Immunol 1995;2:98–103. 10.1128/CDLI.2.1.98-103.1995
    1. Series TS, Assessment D. Diagnostic assessment TSS-6 syphilis rapid diagnostic tests. Geneva World Health Organisation, 2018.

Source: PubMed

3
Prenumerera