The effects of disinfectants on dimensional accuracy and surface quality of impression materials and gypsum casts

Wala M Amin, Muna H Al-Ali, Sandra K Al Tarawneh, Sahar Th Taha, Mohamed W Saleh, Nadia Ereifij, Wala M Amin, Muna H Al-Ali, Sandra K Al Tarawneh, Sahar Th Taha, Mohamed W Saleh, Nadia Ereifij

Abstract

Background: The study aimed to evaluating the effect of disinfecting impression materials on the dimensional accuracy and surface quality of the resulting casts.

Methods: Impressions of a steel die constructed according to ANSI/ADA specification No.18 were made with each of alginate, addition cured silicone, condensation cured silicone and zinc oxide eugenol paste, and disinfected consequently by each of 0.2% chlorhexidine gluconate, 1% sodium hypochlorite, 2% gluteraldehyde for 5 minutes, and 0.5% sodium hypochlorite for 10 minutes. Dimensions of the disinfected impressions and their resultant casts were measured using a computerized digital caliper, and the dimensional changes were calculated. Reproduction of detail and surface quality of the resultant casts were assessed by grading casts surfaces according to a specific scoring system.

Results: The 0.5% sodium hypochlorite was found to produce the least dimensional changes in all the impression materials. Corsodyl produced the maximum changes in both alginate and zinc-oxide eugenol while addition-cured silicon was most affected by Gluteraldehyde and condensation-cured silicon was most affected by Hexana. The dimensional changes, however, were minimal and clinically insignificant. Addition-cured silicon showed the best surface quality and dimensional stability followed by condensation-cured silicon. Alginate and zinc-oxide eugenol had poorer surface quality and were affected to a higher extent by the disinfection procedures.

Conclusions: The results were comparable with the standard specifications for dimensional stability. Recommendations were made for the use of 10 minutes immersion in 0.5% sodium hypochlorite as the most appropriate disinfection protocol to the investigated impression materials.

Keywords: Disinfectants; Gypsum casts; Impressions; Alginate; Addition-cured silicone; Sodium hypochlorite.

Figures

Figure 1
Figure 1
The parts "1, 2, 3" of the assembly constructed according to the ADA specification number 18 for testing dimensional stability and reproduction of details of impression materials. The diagram "4" representing the surface of the die showing the three vertical lines.
Figure 2
Figure 2
Dimensional changes for casts made from alginate impression material after disinfection.
Figure 3
Figure 3
Dimensional changes for casts made from addition silicone impression material after disinfection.
Figure 4
Figure 4
Dimensional changes for casts made from condensation silicone impression material after disinfection.
Figure 5
Figure 5
Dimensional changes for casts made from Zinc Oxide Eugenol impression materials after disinfection.
Figure 6
Figure 6
The distribution of impression materials according to their surface quality grades scored after disinfection.
Figure 7
Figure 7
Surface quality and detail reproduction (X10 magnification): 1- sharp detail, continuous line; 2- continuous lines but with some loss of sharpness; 3- rough appearance with loss of continuity of the line.

References

    1. Leung RL, Schonfeld SE. Gypsum casts as a potential source of microbial cross-contamination. J Prosthet Dent. 1983;49(2):210–211.
    1. Fabiani L, Mosca G, Giuliani AR. Hygiene in dental practices. Eur J Paediatr Dent. 2006;7(2):93–97.
    1. Infection control recommendations for the dental office and the dental laboratory. ADA Council on Scientific Affairs and ADA Council on Dental Practice. J Am Dent Assoc. 1996;127(5):672–680.
    1. Kohn WG, Collins AS, Cleveland JL, Harte JA, Eklund KJ, Malvitz DM. Guidelines for infection control in dental health-care settings--2003. MMWR Recomm Rep. 2003;52(RR-17):1–61.
    1. Taylor RL, Wright PS, Maryan C. Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dent Mater. 2002;18(2):103–110.
    1. Merchant VA, McNeight MK, Ciborowski CJ, Molinari JA. Preliminary investigation of a method for disinfection of dental impressions. J Prosthet Dent. 1984;52(6):877–879.
    1. Herrera SP, Merchant VA. Dimensional stability of dental impressions after immersion disinfection. J Am Dent Assoc. 1986;113(3):419–422.
    1. Palenik CJ, Miller CH. Treating highly infectious patients in the dental office. J Indiana Dent Assoc. 1985;64(5):11–15.
    1. al-Omari WM, Jones JC, Wood DJ. The effect of disinfecting alginate and addition cured silicone rubber impression materials on the physical properties of impressions and resultant casts. Eur J Prosthodont Restor Dent. 1998;6(3):103–110.
    1. Council adopts American Dental Association Specification no. 18 (alginate impression material). Council on Dental Materials and Devices. J Am Dent Assoc. 1968;77(6):1354–1358.
    1. Revised American Dental Association Specification no. 19 for Non-aqueous, Elastomeric Dental Impression Materials. J Am Dent Assoc. 1977;94(4):733–741.
    1. Morrow RM, Brown CE Jr., Stansbury BE, DeLorimier JA, Powell JM, Rudd KD. Compatibility of alginate impression materials and dental stones. J Prosthet Dent. 1971;25(5):556–566.
    1. Amin WM, Taha ST, Al-Tarawneh SK, Saleh MW, Ghzawi A. The relationships of the maxillary central incisors and canines to the incisive papilla in Jordanians. J Contemp Dent Pract. 2008;9(5):42–51.
    1. Millman K. Disinfection of impressions. Br Dent J. 1995;179(9):328.
    1. Matyas J, Dao N, Caputo AA, Lucatorto FM. Effects of disinfectants on dimensional accuracy of impression materials. J Prosthet Dent. 1990;64(1):25–31.
    1. Thouati A, Deveaux E, Iost A, Behin P. Dimensional stability of seven elastomeric impression materials immersed in disinfectants. J Prosthet Dent. 1996;76(1):8–14.
    1. Durr DP, Novak EV. Dimensional stability of alginate impressions immersed in disinfecting solutions. ASDC J Dent Child. 1987;54(1):45–48.
    1. Lepe X, Johnson GH, Berg JC. Surface characteristics of polyether and addition silicone impression materials after long-term disinfection. J Prosthet Dent. 1995;74(2):181–186.
    1. Davis BA, Powers JM. Effect of immersion disinfection on properties of impression materials. J Prosthodont. 1994;3(1):31–34.
    1. Adabo GL, Zanarotti E, Fonseca RG, Cruz CA. Effect of disinfectant agents on dimensional stability of elastomeric impression materials. J Prosthet Dent. 1999;81(5):621–624.
    1. Johansen RE, Stackhouse JA Jr.. Dimensional changes of elastomers during cold sterilization. J Prosthet Dent. 1987;57(2):233–236.

Source: PubMed

3
Prenumerera