Separation of blood cells with differing deformability using deterministic lateral displacement(†)
David Holmes, Graeme Whyte, Joe Bailey, Nuria Vergara-Irigaray, Andrew Ekpenyong, Jochen Guck, Tom Duke, David Holmes, Graeme Whyte, Joe Bailey, Nuria Vergara-Irigaray, Andrew Ekpenyong, Jochen Guck, Tom Duke
Abstract
Determining cell mechanical properties is increasingly recognized as a marker-free way to characterize and separate biological cells. This emerging realization has led to the development of a plethora of appropriate measurement techniques. Here, we use a fairly novel approach, deterministic lateral displacement (DLD), to separate blood cells based on their mechanical phenotype with high throughput. Human red blood cells were treated chemically to alter their membrane deformability and the effect of this alteration on the hydrodynamic behaviour of the cells in a DLD device was investigated. Cells of defined stiffness (glutaraldehyde cross-linked erythrocytes) were used to test the performance of the DLD device across a range of cell stiffness and applied shear rates. Optical stretching was used as an independent method for quantifying the variation in stiffness of the cells. Lateral displacement of cells flowing within the device, and their subsequent exit position from the device were shown to correlate with cell stiffness. Data showing how the isolation of leucocytes from whole blood varies with applied shear rate are also presented. The ability to sort leucocyte sub-populations (T-lymphocytes and neutrophils), based on a combination of cell size and deformability, demonstrates the potential for using DLD devices to perform continuous fractionation and/or enrichment of leucocyte sub-populations from whole blood.
Keywords: blood separation; cell deformability; deterministic lateral displacement; digital holography; microfluidics; optical stretching.
Figures
References
- Guck J, Chilvers ER. 2013. Mechanics meets medicine. Sci. Transl. Med. 5, 212fs41 (10.1126/scitranslmed.3007731)
- Ekpenyong AE, et al. 2012. Viscoelastic properties of differentiating blood cells are fate- and function-dependent. PLoS ONE 7, e45237 (10.1371/journal.pone.0045237)
- Matthews HK, Delabre U, Rohn JL, Guck J, Kunda P, Baum B. 2012. Changes in Ect2 localization couple actomyosin-dependent cell shape changes to mitotic progression. Dev. Cell 23, 371–383. (10.1016/j.devcel.2012.06.003)
- Lautenschläger F, Paschke S, Bruel A, Schinkinger S, Beil M, Guck J. 2009. The regulatory role of cell mechanics for migration of differentiating myeloid cells. Proc. Natl Acad. Sci. USA 106, 15 696–15 701. (10.1073/pnas.0811261106)
- Remmerbach TW, Wottawah F, Dietrich J, Lincoln B, Wittekind C, Guck J. 2009. Oral cancer diagnosis by mechanical phenotyping. Cancer Res. 69, 1728–1732. (10.1158/0008-5472.CAN-08-4073)
- Guck J, et al. 2005. Optical deformability as inherent cell marker for testing malignant transformation and metastatic competence. Biophys. J. 88, 3689–3698. (10.1529/biophysj.104.045476)
- Tse HTK, et al. 2013. Quantitative diagnosis of malignant pleural effusions by single-cell mechanophenotyping. Sci. Transl. Med. 5, 212ra163 (10.1126/scitranslmed.3006559)
- Cross SE, Jin Y-S, Rao J, Gimzewski JK. 2007. Nanomechanical analysis of cells from cancer patients. Nat. Nanotechnol. 2, 780–783. (10.1038/nnano.2007.388)
- Quinn DJ, Pivkin I, Suresh S. 2011. Combined simulation and experimental study of large deformation of red blood cells in microfluidic systems. Ann. Biomed. Eng. 39, 1041–1050. (10.1007/s10439-010-0232-y)
- Suresh S, Spatz J, Mills JP, Micoulet A, Dao M, Lim CT, Beil M, Seufferlein T. 2005. Connections between single-cell biomechanics and human disease states: gastrointestinal cancer and malaria. Acta Biomater. 1, 15–30. (10.1016/j.actbio.2004.09.001)
- Chalut KJ, Höpfler M, Lautenschläger F, Boyde L, Chan CJ, Ekpenyong A, Martinez-Arias A, Guck J. 2012. Chromatin decondensation and nuclear softening accompany Nanog downregulation in embryonic stem cells. Biophys. J. 103, 2060–2070. (10.1016/j.bpj.2012.10.015)
- Worthen GS, Schwab B, 3rd, Elson EL, Downey GP. 1989. Mechanics of stimulated neutrophils: cell stiffening induces retention in capillaries. Science 245, 183–186. (10.1126/science.2749255)
- Erzurum SC, Downey GP, Doherty DE, Schwab B, Elson EL, Worthen GS. 1992. Mechanisms of lipopolysaccharide-induced neutrophil retention. J. Immunol. 149, 154–162.
- Radmacher M. 1997. Measuring the elastic properties of biological samples with the AFM. IEEE Eng. Med. Biol. Mag. 16, 47–57. (10.1109/51.582176)
- Hochmuth RM. 2000. Micropipette aspiration of living cells. J. Biomech. 33, 15–22. (10.1016/S0021-9290(99)00175-X)
- Bausch AR, Möller W, Sackmann E. 1998. Measurement of local viscoelasticity and forces in living cells by magnetic tweezers. Biophys. J. 76, 573–579. (10.1016/S0006-3495(99)77225-5)
- Thoumine O, Ott A. 1997. Time scale dependent viscoelastic and contractile regimes in fibroblasts probed by microplate manipulation. J. Cell Sci. 110, 2109–2116.
- Guck J, Ananthakrishnan R, Mahmood H, Moon TJ, Cunningham CC, Käs J. 2001. The optical stretcher: a novel laser tool to micromanipulate cells. Biophys. J. 81, 767–784. (10.1016/S0006-3495(01)75740-2)
- Gossett DR, et al. 2012. Hydrodynamic stretching of single cells for large population mechanical phenotyping. Proc. Natl Acad. Sci. USA. 109, 7630–7635. (10.1073/pnas.1200107109)
- Hur SC, Henderson-MacLennan NK, McCabe ERB, Di Carlo D. 2011. Deformability-based cell classification and enrichment using inertial microfluidics. Lab Chip 11, 912–920. (10.1039/c0lc00595a)
- Huang LR, Cox EC, Austin RH, Sturm JC. 2004. Continuous particle separation through deterministic lateral displacement. Science 304, 987–990. (10.1126/science.1094567)
- Loutherback K, D'Silva J, Liu L, Wu A, Austin RH, Sturm JC. 2012. Deterministic separation of cancer cells from blood at 10 mL/min. AIP Adv. 2, 042107 (10.1063/1.4758131)
- Davis JA, Inglis DW, Morton KJ, Lawrence DA, Huang LR, Chou SY, Sturm JC, Austin RH. 2006. Deterministic hydrodynamics: taking blood apart. Proc. Natl Acad. Sci. USA 103, 14 779–14 784. (10.1073/pnas.0605967103)
- Morton KJ, et al. 2008. Hydrodynamic metamaterials: microfabricated arrays to steer, refract, and focus streams of biomaterials. Proc. Natl Acad. Sci. USA 105, 7434–7438. (10.1073/pnas.0712398105)
- Inglis DW, Davis JA, Austin RH, Sturm JC. 2006. Critical particle size for fractionation by deterministic lateral displacement. Lab Chip 6, 655–658. (10.1039/b515371a)
- Beech JP, Holm SH, Adolfsson K, Tegenfeldt JO. 2012. Sorting cells by size, shape and deformability. Lab Chip 12, 1048–1051. (10.1039/c2lc21083e)
- Lincoln B, Schinkinger S, Wottawah F, Guck J. 2007. High-throughput cell analysis with a microfluidic optical stretcher. Methods Cell Biol. 83, 397–423. (10.1016/S0091-679X(07)83017-2)
- Lincoln B, Schinkinger S, Travis K, Wottawah F, Ebert S, Sauer F, Guck J. 2007. Reconfigurable microfluidic integration of a dual-beam laser trap with biomedical applications. Biomed. Microdev. 9, 703–710. (10.1007/s10544-007-9079-x)
- Guck J, Ananthakrishnan R, Moon TJ, Cunningham CC, Käs J. 2000. Optical deformability of soft biological dielectrics. Phys. Rev. Lett. 84, 5451–5454. (10.1103/PhysRevLett.84.5451)
- Boyde L, Chalut K, Guck J. 2009. Interaction of a Gaussian beam with a near-spherical particle: an analytic-numerical approach for assessing scattering and stresses. J. Opt. Soc. Am. A 26, 1814–1826. (10.1364/JOSAA.26.001814)
- Tong X, Caldwell KD. 1995. Separation and characterisation of red blood cells with different membrane deformability using steric field-flow fractionation. J Chromatogr. D 674, 39–47. (10.1016/0378-4347(95)00297-0)
- Mauritz JMA, Tiffert T, Seear R, Lautenschläger F, Esposito A, Lew VL, Guck J, Kaminski CF. 2010. Detection of Plasmodium falciparum-infected red blood cells by optical stretching. J. Biomed. Opt. 15, 030517 (10.1117/1.3458919)
Source: PubMed