此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Aortic Valve and Root Measurements Under Real-Time 3-Dimensional Visualization During Angiography

2017年7月13日 更新者:NYU Langone Health

The American College of Cardiology/American Heart Association guidelines place symptomatic severe Aortic Stenosis as a class I indication for aortic valve replacement. With the recently approved Edwards-Sapien TAVR device and the ongoing investigations using the CoreValve TAVR device, patients ineligible or at high risk for open-heart surgery are now eligible to undergo TAVR.

Patients selected for TAVR undergo an EKG-gated cardiac Multislice CTA to evaluate aortic valve anatomy and aortic root dimensions for device sizing, as well as coronary angiography to define coronary anatomy. Both tests utilize contrast media to visualize anatomy, which may result in contrast-induced nephropathy in anywhere from 7.5% to more than 50% of patients depending on associated clinical risk factors.

There is a need to consolidate this pre-operative testing whenever possible, and with real-time 3-dimensional visualization of aortic valve and root anatomy using DynaCT cardiac acquisition in the cath lab angiography suite during the coronary angiography, there may be a benefit with reduced contrast load (20 to 35cc for DynaCT, 100cc for CTA).

We would like to make a comparison of aortic valve and root measurements using CTA and DynaCT to affirm the accuracy of DynaCT vs the CTA gold standard.

研究概览

详细说明

Calcific or degenerative aortic valve disease is one of the most common valvular diseases among the elderly and, with life expectancy continuing to increase, a major source of burden on current healthcare. Although patients with aortic stenosis (AS) can remain asymptomatic for a prolonged period, they do eventually develop symptoms, including angina, exertional syncope and heart failure, which is associated with a 5-year, 3-year, and 1-year, respectively, 50% mortality. The American College of Cardiology/American Heart Association guidelines place symptomatic severe AS as a class I indication for aortic valve replacement. Currently, surgical replacement of the aortic valve is the standard of care. However, with the recently approved Edwards-Sapient TAVR device and the ongoing investigations using the CoreValve TAVR device, patients ineligible or at high risk for open-heart surgery are now eligible to undergo TAVR.

Currently, patients selected for TAVR undergo an EKG-gated cardiac Multislice CTA to evaluate aortic valve anatomy and aortic root dimensions for device sizing. Patients also undergo coronary angiography to define coronary anatomy. Both tests utilize contrast media to visualize anatomy, which may result in contrast-induced nephropathy in anywhere from 7.5% to more than 50% of patients depending on associated clinical risk factors. Contrast-induced nephropathy can, in turn, lead to dialysis and/or increased mortality.

There is a need to consolidate this pre-operative testing whenever possible, and with real-time 3-dimensional visualization of aortic valve and root anatomy using DynaCT cardiac acquisition in the cath lab angiography suite during the coronary angiography, there may be a benefit with reduced contrast load (20 to 35cc for DynaCT, 100cc for CTA). DynaCT conducts fully automatic aortic root segmentation and overlays 3-dimensional structures onto 2-dimensional fluoroscopy in a few seconds (~5 seconds, 60 frames/second rotational angiography). The software automatically recognizes and represents the aortic root, detects and indicates coronary ostia and lowest cusp points of aortic valve (nadir points), and reconstructs commissure lines of aortic valve. Due to cardiac motion, 3-dimensional images without motion correction or cardiac gating will look blurred. Therefore, DynaCT reconstruction motion correction software will be used. The DynaCT motion correction software is a new algorithm that will correct for this motion and apply it during reconstruction- allowing the user to spin without using rapid pacing. However, first, a comparison of aortic valve and root measurements using CTA and DynaCT must be made to affirm the accuracy of DynaCT vs the CTA gold standard.

Study Design This is a pilot study evaluating patients undergoing TAVR at the New York University (NYU) Langone Medical Center. Patients will undergo the standard CTA protocol and invasive coronary angiography performed as part of the pre-operative assessment for TAVR. However, patients in this study will also undergo DynaCT during coronary angiography, utilizing 1 acquisition sweep and 20 to 35cc more of contrast media. Measurements of the major aortic annulus diameter, orthogonal minor aortic annulus diameter, aortic annulus perimeter, maximum ascending aorta diameter at 40mm above the annulus, sinus of Valsalva diameters, sinus of Valsalva heights, and aortic root angulation will be made using both the CTA and DynaCT protocols by a radiologist blinded to patient identity after the study has reached its target recruitment. Based on these measurements, a trained interventional cardiologist will select the appropriate TAVR size in a similarly blinded fashion after the study has reached its target recruitment (i.e. the data collected using DynaCT will not be used in the clinical decision making process). Data will be compared from both modalities using appropriate tests of reproducibility and correlation.

Study Technique CTA will be performed per standard methods as part of standard pre-TAVR evaluation.

Coronary angiography will be performed via femoral artery access (minimum 6Fr) as per standard pre-TAVR evaluation. After coronary angiography is performed, a 6Fr pigtail catheter will be placed in the aorta and 40cc of 50% contrast media diluted normal saline will be delivered using standard automated injection during dynaCT cardiac image acquisition. Intravenous delivery of contrast was considered as alternative.

As per standard care, intravenous access will be obtained and participants will be hydrated during the CTA, coronary angiography, and dynaCT procedures.

研究类型

介入性

注册 (实际的)

25

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • New York
      • New York、New York、美国、10016
        • NYU Langone Medical Center

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Subjects must be more than 18 years of age with a plan to undergo TAVR.

Exclusion Criteria:

  • Subjects will be excluded if they meet one of the following criteria:

    1. estimated glomerular filtration rate <40 mL/min/1.73m2;
    2. highly irregular heart rates, frequent extra systoles, additional extra pulsations, not in sinus heart rhythm;
    3. allergy to contrast media;
    4. pregnant; or
    5. Unable to consent.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:诊断
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Real-time 3-dimensional DynaCT
Patients will undergo the standard CTA protocol and invasive coronary angiography performed as part of the pre-operative assessment for TAVR. Patients in this study will also undergo DynaCT during coronary angiography, utilizing 1 acquisition sweep and 20 to 35cc more of contrast media. Measurements of the major aortic annulus diameter, orthogonal minor aortic annulus diameter, aortic annulus perimeter, maximum ascending aorta diameter at 40mm above the annulus, sinus of Valsalva diameters, sinus of Valsalva heights, and aortic root angulation will be made using both the CTA and DynaCT protocols by a radiologist blinded to patient identity. Based on these measurements, a trained interventional cardiologist will select the appropriate TAVR size for the patient.
After coronary angiography is performed, a 6Fr pigtail catheter will be placed in the aorta and 40cc of 50% contrast media diluted normal saline will be delivered using standard automated injection during dynaCT cardiac image acquisition. Intravenous delivery of contrast as alternative.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Correlation of aortic annulus measurement measured on invasive 3D dyna CT (experimental) and on non-invasive CT scan (standard of care)
大体时间:1 day
Each patient will undergo non-invasive CT scan for aortic annulus measurement (in order to choose appropriate TAVR size) as per standard of care. They will then undergo invasive dyna CT for aortic annulus measurement during their clinically-indicated invasive coronary angiogram. The primary outcome is correlation between the aortic annulus dimension measurement made on dyna CT and non-invasive CT.
1 day

次要结果测量

结果测量
措施说明
大体时间
TAVR size
大体时间:1 day
A trained interventional cardiologist will evaluate the measurements made from each CTA abd DynaCT image and select the appropriate TAVR size in a blinded fashion.
1 day

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2014年1月6日

初级完成 (实际的)

2016年6月22日

研究完成 (实际的)

2017年6月13日

研究注册日期

首次提交

2014年2月19日

首先提交符合 QC 标准的

2014年2月26日

首次发布 (估计)

2014年2月27日

研究记录更新

最后更新发布 (实际的)

2017年7月18日

上次提交的符合 QC 标准的更新

2017年7月13日

最后验证

2017年7月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

研究美国 FDA 监管的设备产品

在美国制造并从美国出口的产品

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

Real-time 3-dimensional DynaCT的临床试验

3
订阅