Stent under-expansion during percutaneous coronary intervention (PCI) is one of the suboptimal results associated with a higher risk of restenosis and thrombosis. In order to obtain an optimal stent expansion, especially in lesions with calcific or fibrotic plaque, the appropriate lesion preparation before stent implantation is a crucial phase.

For this, different devices are used in everyday practices, including non-compliant balloon (NC), scoring / cutting balloons or rotational atherectomy; however, their effectiveness depends on the experience and skill of the operator. The purpose of this study is to assess the feasibility, efficacy and safety of a novel scoring balloon intended to treat calcific or fibrotic plaque of a coronary lesion

研究概览

研究类型

介入性

注册 (预期的)

100

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

学习地点

      • Genk、比利时、3600
        • 招聘中
        • UZ Genk
        • 接触:
          • Jo Dens
      • Ghent、比利时、9000
        • 招聘中
        • UZ Ghent
        • 接触:
          • Peter Kayaert
      • La Louvière、比利时、7100
        • 招聘中
        • CHU Jolimont
        • 接触:
          • Claudiu Ungureanu
      • Liège、比利时、4000
        • 招聘中
        • CHU Liège
        • 接触:
          • Lancelotti
      • Mons、比利时、7000

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

是的

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Patient written consent is given A de novo lesion
  • Mild to moderate burden of calcifications detected on two orthogonal views using normal radiation power

Exclusion Criteria:

  • Exclusion criteria patient-related:

    1. Patient <18 years old
    2. Pregnant female
    3. Contraindication to dual antiplatelet therapy
    4. Thrombocytopenia <100 000
    5. Major surgical intervention planned

Exclusion criteria lesion-related:

  1. Significant left main lesion
  2. Bifurcating lesion with a significant side branch to be treated
  3. Lesion length > 25 mm
  4. Chronic total occlusion
  5. Lesion with heavy calcifications where a rotational atherectomy or lithotripsy should be planned
  6. Lesion in a graft
  7. In-stent restenosis lesion
  8. Lesion responsible of a STEMI

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:双倍的

武器和干预

参与者组/臂
干预/治疗
有源比较器:Conventional balloon predilation
the target lesion can be prepared according to standard clinical practice using SC balloons sized 0.8-1:1. Stenting using a drug-eluting stent (DES) is performed and the inflation pressure for delivery is noted, as well as the expected balloon diameter at that pressure. 2 enhanced stent imaging acquisitions (StentBoost or equivalent depending on the X-ray system used), are acquired in 2 orthogonal views. Post dilatation can be performed at operator discretion followed by a final acquisition of 2 similar orthogonal views with enhanced stent imaging. Intravascular imaging is left to the operator's discretion and is encouraged
Conventional balloon
实验性的:Scoring balloon predilation
the target lesion must be prepared with a scoring balloon (SC) inflated 3 times at nominal pressure. To allow the scoring balloon to cross the lesion, it might be necessary to predilate with a small compliant balloon. The size of the scoring balloon to be used for is based on the size of the vessel. Stenting using a DES is performed and the inflation pressure for delivery is noted, as well as the expected balloon diameter at that pressure. 2 enhanced stent imaging acquisitions (StentBoost or equivalent depending on the X-ray system used), are acquired in 2 orthogonal views. Post dilatation can be performed at operator discretion followed by a final acquisition of 2 similar orthogonal views with enhanced stent imaging. Intravascular imaging is left to the operator's discretion and is encouraged
Scoring balloon

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Stent expansion in calcified lesions assessed by stent diameter calculation using quantitative and intravascular analysis after lesion preparation using a scoring balloon is superior to conventional lesion preparation
大体时间:Intravascular ultrasound (IVUS) or quantitative analysis is directly done after procedure
The measure of stent expansion in calcified coronary lesions as assessed by quantitative coronary angiography, enhanced stent imaging and intravascular ultrasound after lesion preparation using the novel scoring semi-compliant and noncompliant balloons are superior (p<0.05) to semi compliant and non-compliant balloons.
Intravascular ultrasound (IVUS) or quantitative analysis is directly done after procedure

次要结果测量

结果测量
大体时间
Rate of successful predilatation of calcified lesions of a scoring semi-compliant/non-compliant balloon and semi-compliant (SC)/ non-compliant (NC) balloon
大体时间:Directly after procedure
Directly after procedure
Rate of residual under-expansion of stent after post-dilatation with a non-compliant balloon
大体时间:Directly after procedure
Directly after procedure
Rate of procedural complication (composite of cardiac death, myocardial infarction, coronary artery perforation and cardiac tamponade) of a scoring balloon and a SC/NC balloon followed by stenting.
大体时间:1 month follow up
1 month follow up

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Stéphane Carlier、University of Mons

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2020年1月1日

初级完成 (预期的)

2022年7月30日

研究完成 (预期的)

2022年10月30日

研究注册日期

首次提交

2021年8月13日

首先提交符合 QC 标准的

2021年8月18日

首次发布 (实际的)

2021年8月24日

研究记录更新

最后更新发布 (实际的)

2021年8月24日

上次提交的符合 QC 标准的更新

2021年8月18日

最后验证

2021年8月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅