Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

WEDGES: Coronary Lesion Preparation With Enhanced Dilatation for Good Expansion of Stent: Assessment of a New Scoring Balloon by Quantitative Stent Enhanced Visualization (WEDGES)

18 sierpnia 2021 zaktualizowane przez: Stephane Carlier

WEDGES: a Prospective, Multi-center Randomized Trial for the Evaluation of Coronary Lesion Preparation With Enhanced Dilatation for Good Expansion of Stent: Assessment of a New Scoring Balloon by Quantitative Stent Enhanced Visualization

Stent under-expansion during percutaneous coronary intervention (PCI) is one of the suboptimal results associated with a higher risk of restenosis and thrombosis. In order to obtain an optimal stent expansion, especially in lesions with calcific or fibrotic plaque, the appropriate lesion preparation before stent implantation is a crucial phase.

For this, different devices are used in everyday practices, including non-compliant balloon (NC), scoring / cutting balloons or rotational atherectomy; however, their effectiveness depends on the experience and skill of the operator. The purpose of this study is to assess the feasibility, efficacy and safety of a novel scoring balloon intended to treat calcific or fibrotic plaque of a coronary lesion

Przegląd badań

Typ studiów

Interwencyjne

Zapisy (Oczekiwany)

100

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kopia zapasowa kontaktu do badania

Lokalizacje studiów

      • Genk, Belgia, 3600
        • Rekrutacyjny
        • UZ Genk
        • Kontakt:
          • Jo Dens
      • Ghent, Belgia, 9000
        • Rekrutacyjny
        • UZ Ghent
        • Kontakt:
          • Peter Kayaert
      • La Louvière, Belgia, 7100
        • Rekrutacyjny
        • CHU Jolimont
        • Kontakt:
          • Claudiu Ungureanu
      • Liège, Belgia, 4000
        • Rekrutacyjny
        • CHU Liege
        • Kontakt:
          • Lancelotti
      • Mons, Belgia, 7000

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat i starsze (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Tak

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  • Patient written consent is given A de novo lesion
  • Mild to moderate burden of calcifications detected on two orthogonal views using normal radiation power

Exclusion Criteria:

  • Exclusion criteria patient-related:

    1. Patient <18 years old
    2. Pregnant female
    3. Contraindication to dual antiplatelet therapy
    4. Thrombocytopenia <100 000
    5. Major surgical intervention planned

Exclusion criteria lesion-related:

  1. Significant left main lesion
  2. Bifurcating lesion with a significant side branch to be treated
  3. Lesion length > 25 mm
  4. Chronic total occlusion
  5. Lesion with heavy calcifications where a rotational atherectomy or lithotripsy should be planned
  6. Lesion in a graft
  7. In-stent restenosis lesion
  8. Lesion responsible of a STEMI

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Podwójnie

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Aktywny komparator: Conventional balloon predilation
the target lesion can be prepared according to standard clinical practice using SC balloons sized 0.8-1:1. Stenting using a drug-eluting stent (DES) is performed and the inflation pressure for delivery is noted, as well as the expected balloon diameter at that pressure. 2 enhanced stent imaging acquisitions (StentBoost or equivalent depending on the X-ray system used), are acquired in 2 orthogonal views. Post dilatation can be performed at operator discretion followed by a final acquisition of 2 similar orthogonal views with enhanced stent imaging. Intravascular imaging is left to the operator's discretion and is encouraged
Conventional balloon
Eksperymentalny: Scoring balloon predilation
the target lesion must be prepared with a scoring balloon (SC) inflated 3 times at nominal pressure. To allow the scoring balloon to cross the lesion, it might be necessary to predilate with a small compliant balloon. The size of the scoring balloon to be used for is based on the size of the vessel. Stenting using a DES is performed and the inflation pressure for delivery is noted, as well as the expected balloon diameter at that pressure. 2 enhanced stent imaging acquisitions (StentBoost or equivalent depending on the X-ray system used), are acquired in 2 orthogonal views. Post dilatation can be performed at operator discretion followed by a final acquisition of 2 similar orthogonal views with enhanced stent imaging. Intravascular imaging is left to the operator's discretion and is encouraged
Scoring balloon

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Stent expansion in calcified lesions assessed by stent diameter calculation using quantitative and intravascular analysis after lesion preparation using a scoring balloon is superior to conventional lesion preparation
Ramy czasowe: Intravascular ultrasound (IVUS) or quantitative analysis is directly done after procedure
The measure of stent expansion in calcified coronary lesions as assessed by quantitative coronary angiography, enhanced stent imaging and intravascular ultrasound after lesion preparation using the novel scoring semi-compliant and noncompliant balloons are superior (p<0.05) to semi compliant and non-compliant balloons.
Intravascular ultrasound (IVUS) or quantitative analysis is directly done after procedure

Miary wyników drugorzędnych

Miara wyniku
Ramy czasowe
Rate of successful predilatation of calcified lesions of a scoring semi-compliant/non-compliant balloon and semi-compliant (SC)/ non-compliant (NC) balloon
Ramy czasowe: Directly after procedure
Directly after procedure
Rate of residual under-expansion of stent after post-dilatation with a non-compliant balloon
Ramy czasowe: Directly after procedure
Directly after procedure
Rate of procedural complication (composite of cardiac death, myocardial infarction, coronary artery perforation and cardiac tamponade) of a scoring balloon and a SC/NC balloon followed by stenting.
Ramy czasowe: 1 month follow up
1 month follow up

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Dyrektor Studium: Stéphane Carlier, University of Mons

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

1 stycznia 2020

Zakończenie podstawowe (Oczekiwany)

30 lipca 2022

Ukończenie studiów (Oczekiwany)

30 października 2022

Daty rejestracji na studia

Pierwszy przesłany

13 sierpnia 2021

Pierwszy przesłany, który spełnia kryteria kontroli jakości

18 sierpnia 2021

Pierwszy wysłany (Rzeczywisty)

24 sierpnia 2021

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

24 sierpnia 2021

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

18 sierpnia 2021

Ostatnia weryfikacja

1 sierpnia 2021

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

produkt wyprodukowany i wyeksportowany z USA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Choroba wieńcowa

Badania kliniczne na Conventional Balloon

3
Subskrybuj