Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

WEDGES: Coronary Lesion Preparation With Enhanced Dilatation for Good Expansion of Stent: Assessment of a New Scoring Balloon by Quantitative Stent Enhanced Visualization (WEDGES)

18 agosto 2021 aggiornato da: Stephane Carlier

WEDGES: a Prospective, Multi-center Randomized Trial for the Evaluation of Coronary Lesion Preparation With Enhanced Dilatation for Good Expansion of Stent: Assessment of a New Scoring Balloon by Quantitative Stent Enhanced Visualization

Stent under-expansion during percutaneous coronary intervention (PCI) is one of the suboptimal results associated with a higher risk of restenosis and thrombosis. In order to obtain an optimal stent expansion, especially in lesions with calcific or fibrotic plaque, the appropriate lesion preparation before stent implantation is a crucial phase.

For this, different devices are used in everyday practices, including non-compliant balloon (NC), scoring / cutting balloons or rotational atherectomy; however, their effectiveness depends on the experience and skill of the operator. The purpose of this study is to assess the feasibility, efficacy and safety of a novel scoring balloon intended to treat calcific or fibrotic plaque of a coronary lesion

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Anticipato)

100

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

      • Genk, Belgio, 3600
        • Reclutamento
        • UZ Genk
        • Contatto:
          • Jo Dens
      • Ghent, Belgio, 9000
        • Reclutamento
        • UZ Ghent
        • Contatto:
          • Peter Kayaert
      • La Louvière, Belgio, 7100
        • Reclutamento
        • CHU Jolimont
        • Contatto:
          • Claudiu Ungureanu
      • Liège, Belgio, 4000
        • Reclutamento
        • Chu Liege
        • Contatto:
          • Lancelotti
      • Mons, Belgio, 7000

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Patient written consent is given A de novo lesion
  • Mild to moderate burden of calcifications detected on two orthogonal views using normal radiation power

Exclusion Criteria:

  • Exclusion criteria patient-related:

    1. Patient <18 years old
    2. Pregnant female
    3. Contraindication to dual antiplatelet therapy
    4. Thrombocytopenia <100 000
    5. Major surgical intervention planned

Exclusion criteria lesion-related:

  1. Significant left main lesion
  2. Bifurcating lesion with a significant side branch to be treated
  3. Lesion length > 25 mm
  4. Chronic total occlusion
  5. Lesion with heavy calcifications where a rotational atherectomy or lithotripsy should be planned
  6. Lesion in a graft
  7. In-stent restenosis lesion
  8. Lesion responsible of a STEMI

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Doppio

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Comparatore attivo: Conventional balloon predilation
the target lesion can be prepared according to standard clinical practice using SC balloons sized 0.8-1:1. Stenting using a drug-eluting stent (DES) is performed and the inflation pressure for delivery is noted, as well as the expected balloon diameter at that pressure. 2 enhanced stent imaging acquisitions (StentBoost or equivalent depending on the X-ray system used), are acquired in 2 orthogonal views. Post dilatation can be performed at operator discretion followed by a final acquisition of 2 similar orthogonal views with enhanced stent imaging. Intravascular imaging is left to the operator's discretion and is encouraged
Conventional balloon
Sperimentale: Scoring balloon predilation
the target lesion must be prepared with a scoring balloon (SC) inflated 3 times at nominal pressure. To allow the scoring balloon to cross the lesion, it might be necessary to predilate with a small compliant balloon. The size of the scoring balloon to be used for is based on the size of the vessel. Stenting using a DES is performed and the inflation pressure for delivery is noted, as well as the expected balloon diameter at that pressure. 2 enhanced stent imaging acquisitions (StentBoost or equivalent depending on the X-ray system used), are acquired in 2 orthogonal views. Post dilatation can be performed at operator discretion followed by a final acquisition of 2 similar orthogonal views with enhanced stent imaging. Intravascular imaging is left to the operator's discretion and is encouraged
Scoring balloon

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Stent expansion in calcified lesions assessed by stent diameter calculation using quantitative and intravascular analysis after lesion preparation using a scoring balloon is superior to conventional lesion preparation
Lasso di tempo: Intravascular ultrasound (IVUS) or quantitative analysis is directly done after procedure
The measure of stent expansion in calcified coronary lesions as assessed by quantitative coronary angiography, enhanced stent imaging and intravascular ultrasound after lesion preparation using the novel scoring semi-compliant and noncompliant balloons are superior (p<0.05) to semi compliant and non-compliant balloons.
Intravascular ultrasound (IVUS) or quantitative analysis is directly done after procedure

Misure di risultato secondarie

Misura del risultato
Lasso di tempo
Rate of successful predilatation of calcified lesions of a scoring semi-compliant/non-compliant balloon and semi-compliant (SC)/ non-compliant (NC) balloon
Lasso di tempo: Directly after procedure
Directly after procedure
Rate of residual under-expansion of stent after post-dilatation with a non-compliant balloon
Lasso di tempo: Directly after procedure
Directly after procedure
Rate of procedural complication (composite of cardiac death, myocardial infarction, coronary artery perforation and cardiac tamponade) of a scoring balloon and a SC/NC balloon followed by stenting.
Lasso di tempo: 1 month follow up
1 month follow up

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Direttore dello studio: Stéphane Carlier, University of Mons

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 gennaio 2020

Completamento primario (Anticipato)

30 luglio 2022

Completamento dello studio (Anticipato)

30 ottobre 2022

Date di iscrizione allo studio

Primo inviato

13 agosto 2021

Primo inviato che soddisfa i criteri di controllo qualità

18 agosto 2021

Primo Inserito (Effettivo)

24 agosto 2021

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

24 agosto 2021

Ultimo aggiornamento inviato che soddisfa i criteri QC

18 agosto 2021

Ultimo verificato

1 agosto 2021

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Disfunsione dell'arteria coronaria

Prove cliniche su Conventional Balloon

Sottoscrivi