WEDGES: Coronary Lesion Preparation With Enhanced Dilatation for Good Expansion of Stent: Assessment of a New Scoring Balloon by Quantitative Stent Enhanced Visualization (WEDGES)

18 de agosto de 2021 atualizado por: Stephane Carlier

WEDGES: a Prospective, Multi-center Randomized Trial for the Evaluation of Coronary Lesion Preparation With Enhanced Dilatation for Good Expansion of Stent: Assessment of a New Scoring Balloon by Quantitative Stent Enhanced Visualization

Stent under-expansion during percutaneous coronary intervention (PCI) is one of the suboptimal results associated with a higher risk of restenosis and thrombosis. In order to obtain an optimal stent expansion, especially in lesions with calcific or fibrotic plaque, the appropriate lesion preparation before stent implantation is a crucial phase.

For this, different devices are used in everyday practices, including non-compliant balloon (NC), scoring / cutting balloons or rotational atherectomy; however, their effectiveness depends on the experience and skill of the operator. The purpose of this study is to assess the feasibility, efficacy and safety of a novel scoring balloon intended to treat calcific or fibrotic plaque of a coronary lesion

Visão geral do estudo

Tipo de estudo

Intervencional

Inscrição (Antecipado)

100

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Estude backup de contato

Locais de estudo

      • Genk, Bélgica, 3600
        • Recrutamento
        • UZ Genk
        • Contato:
          • Jo Dens
      • Ghent, Bélgica, 9000
        • Recrutamento
        • UZ Ghent
        • Contato:
          • Peter Kayaert
      • La Louvière, Bélgica, 7100
        • Recrutamento
        • CHU Jolimont
        • Contato:
          • Claudiu Ungureanu
      • Liège, Bélgica, 4000
        • Recrutamento
        • Chu Liege
        • Contato:
          • Lancelotti
      • Mons, Bélgica, 7000

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Sim

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Patient written consent is given A de novo lesion
  • Mild to moderate burden of calcifications detected on two orthogonal views using normal radiation power

Exclusion Criteria:

  • Exclusion criteria patient-related:

    1. Patient <18 years old
    2. Pregnant female
    3. Contraindication to dual antiplatelet therapy
    4. Thrombocytopenia <100 000
    5. Major surgical intervention planned

Exclusion criteria lesion-related:

  1. Significant left main lesion
  2. Bifurcating lesion with a significant side branch to be treated
  3. Lesion length > 25 mm
  4. Chronic total occlusion
  5. Lesion with heavy calcifications where a rotational atherectomy or lithotripsy should be planned
  6. Lesion in a graft
  7. In-stent restenosis lesion
  8. Lesion responsible of a STEMI

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Conventional balloon predilation
the target lesion can be prepared according to standard clinical practice using SC balloons sized 0.8-1:1. Stenting using a drug-eluting stent (DES) is performed and the inflation pressure for delivery is noted, as well as the expected balloon diameter at that pressure. 2 enhanced stent imaging acquisitions (StentBoost or equivalent depending on the X-ray system used), are acquired in 2 orthogonal views. Post dilatation can be performed at operator discretion followed by a final acquisition of 2 similar orthogonal views with enhanced stent imaging. Intravascular imaging is left to the operator's discretion and is encouraged
Conventional balloon
Experimental: Scoring balloon predilation
the target lesion must be prepared with a scoring balloon (SC) inflated 3 times at nominal pressure. To allow the scoring balloon to cross the lesion, it might be necessary to predilate with a small compliant balloon. The size of the scoring balloon to be used for is based on the size of the vessel. Stenting using a DES is performed and the inflation pressure for delivery is noted, as well as the expected balloon diameter at that pressure. 2 enhanced stent imaging acquisitions (StentBoost or equivalent depending on the X-ray system used), are acquired in 2 orthogonal views. Post dilatation can be performed at operator discretion followed by a final acquisition of 2 similar orthogonal views with enhanced stent imaging. Intravascular imaging is left to the operator's discretion and is encouraged
Scoring balloon

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Stent expansion in calcified lesions assessed by stent diameter calculation using quantitative and intravascular analysis after lesion preparation using a scoring balloon is superior to conventional lesion preparation
Prazo: Intravascular ultrasound (IVUS) or quantitative analysis is directly done after procedure
The measure of stent expansion in calcified coronary lesions as assessed by quantitative coronary angiography, enhanced stent imaging and intravascular ultrasound after lesion preparation using the novel scoring semi-compliant and noncompliant balloons are superior (p<0.05) to semi compliant and non-compliant balloons.
Intravascular ultrasound (IVUS) or quantitative analysis is directly done after procedure

Medidas de resultados secundários

Medida de resultado
Prazo
Rate of successful predilatation of calcified lesions of a scoring semi-compliant/non-compliant balloon and semi-compliant (SC)/ non-compliant (NC) balloon
Prazo: Directly after procedure
Directly after procedure
Rate of residual under-expansion of stent after post-dilatation with a non-compliant balloon
Prazo: Directly after procedure
Directly after procedure
Rate of procedural complication (composite of cardiac death, myocardial infarction, coronary artery perforation and cardiac tamponade) of a scoring balloon and a SC/NC balloon followed by stenting.
Prazo: 1 month follow up
1 month follow up

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Diretor de estudo: Stéphane Carlier, University of Mons

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de janeiro de 2020

Conclusão Primária (Antecipado)

30 de julho de 2022

Conclusão do estudo (Antecipado)

30 de outubro de 2022

Datas de inscrição no estudo

Enviado pela primeira vez

13 de agosto de 2021

Enviado pela primeira vez que atendeu aos critérios de CQ

18 de agosto de 2021

Primeira postagem (Real)

24 de agosto de 2021

Atualizações de registro de estudo

Última Atualização Postada (Real)

24 de agosto de 2021

Última atualização enviada que atendeu aos critérios de controle de qualidade

18 de agosto de 2021

Última verificação

1 de agosto de 2021

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever