- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT00581386
Clinical Comparison of the Airway Devices
A Randomized Clinical Comparison Of The King Systems Disposable Laryngeal Tube Suction (LTS-D), The Esophageal Tracheal Combitube (ETC) And The Proseal Laryngeal Mask Airway (PLMA) In Adult Patients
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
During the past decade, several pharyngeal airways have been introduced into clinical practice for airway management, such as the Laryngeal Mask Airway (LMA), the Cuffed Oropharyngeal Airway (COPA), the Esophageal Tracheal Combitube (ETC), and most recently, the Laryngeal Tube (LT). These airway devices have become very popular because of their ability to maintain an airway without perturbing the trachea, and can be used in patients without muscle relaxation and who are only lightly anesthetized.
The LMA generally provides an adequate airway, but certain problems remain. (1) In 8-33% of LMA placements, more than one attempt is required. (2) It is sometimes difficult to advance the LMA without extending the neck (which is contraindicated in some patients). (3) The device does not protect the airway from aspiration of gastric contents. (4) It does not provide an airtight seal around the larynx (the usual pressures causing leakage of gas being 15-20 cm H20). Consequently, the device functions poorly during positive-pressure ventilation. (5) The esophagus is included within the rim of the LMA in 10-15% of patients, directly exposing the esophagus to positive airway pressures. This often results in insufflation of the stomach and postoperative discomfort.
The ETC is a disposable double-lumen tube that combines the features of a conventional endotracheal tube with those of an esophageal obturator airway. It is appropriate for prehospital, intraoperative, and emergency use and is especially useful for patients in whom direct visualization of the vocal cords is not possible, patients with massive airway bleeding or regurgitation, limited access to the airway, and patients in whom neck movement is contraindicated. Ventilation with the ETC is possible with either tracheal or esophageal intubation, as its distal cuff seals off the esophagus to prevent aspiration of gastric contents. The ETC has a 6.9% incidence of placement failure and a failed ventilation rate of 21.1%.
The Laryngeal Tube Suction (LTS; VBM Medizintechnik; King Systems, Noblesville, IN) is a supra-glottic airway device designed to provide a more effective seal than the LMA, thus eliminating problems 3-5 described above. The insertion of the standard laryngeal tube is generally easy. The reported success rate of insertion of, and ventilation through, the laryngeal tube ranges from 92-100% for the earlier prototype and 97-100% for the newest version. It is a flexible, curved tube that passes through the mouth, advances posterior to the epiglottis, and terminates in the upper esophagus. The multi-use, double-lumen, silicon LTS is designed with ventilation outlets located between an oropharyngeal and an esophageal, low-pressure cuff. The second lumen allows for an orogastric tube to be passed through for gastric drainage and pressure release. Patients at risk of regurgitation now have an alternative to tracheal intubation. This device has been used in a number of patients by anesthesiologists in Europe. There are many published scientific abstracts in the use of the LTS. A disposable version of the LTS is now available, the LTS-D. The LTS-D offers the same benefits as the LTS, but being disposable, it also eliminates the risk of cross-infection.
The ProSeal Laryngeal Mask Airway (PLMA, LMA North America Inc.) is the pre-existing double-lumen supra-glottic device that allows gastric drainage and pressure release. Its design is based on the LMA with an added lumen. It is reusable. The ProSeal exhibits an unsuccessful ventilation rate of 9%, and a first time insertion failure of 12.7%. Currently, the ProSeal exhibits a 3% incidence of foldover during insertion that prevents it from functioning properly. Due to differences in design, we postulate that the LTS-D will have a lower incidence of foldover than the PLMA.
This clinical study has been designed to compare the ProSeal, ETC and LTS-D as to the ease of placement and ventilation during controlled ventilation, proper positioning, the seal pressure with each placement, the patency of the drain tube by suctioning and measuring stomach contents, and finally, any complications with their use. Fiberoptic observations through each device will provide information in relation to the epiglottis and the distal opening of the device.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Texas
-
Houston, Texas, United States, 77030
- Memorial Hermann Hospital
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- The subjects will be adult surgical candidates aged 18-80, ASA I-III, Mallampati I or II, presenting for elective surgery who require general anesthesia in whom tracheal intubation is not necessary.
- Both male and female patients will be included.
Exclusion Criteria:
Patients will be excluded from the study if they present as Mallampati III or IV, ASA IV-V or emergency status. Additionally, they will be excluded if they meet one of the contraindication criteria of the LMA ProSeal including:
- Obesity
- Pregnancy
- History of gastric regurgitation, heart burn, ileus or "full stomach"
- History of low pulmonary compliance or high pulmonary resistance
- Known history of difficult endotracheal intubation or signs suggesting the possibility of difficult intubation
- Pharyngeal pathology or
- Upper airway obstruction due to laryngeal pathology.
Additionally, they will be excluded if they meet one of the contraindication criteria for the Combitube including:
- Intact gag reflexes
- Height <4 feet
- Central airway obstruction
- Recent ingestion of caustic substances
- Known esophageal pathology, or
- Known latex allergy.
- They will also be excluded if any tracheal disease is present such as tracheal tumors, stenosis or previous tracheal surgery.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: LTS-D
All the cases were divided into one of the group LTS-D, PLMA, and ETC
|
supra-glottic airway device
Other Names:
|
|
Experimental: ProSeal Laryngeal Mask Airway
All patients were divided into either LTS-D, PLMA, or the ETC group.
|
pre-existing double-lumen supra-glottic device
Other Names:
|
|
Experimental: Esophageal Tracheal Combitube (ETC)
All patients are divided into one of the group, LTS-D, PLMA, or the ETC.
|
disposable double-lumen tube
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Duration of Intubation
Time Frame: duration of intubation
|
The time taken to successfully place the device in seconds.
|
duration of intubation
|
|
Number of Participants With a Successful First Attempt Placement
Time Frame: Time taken for successful placement
|
The number of patients in whom the assigned device was successfully placed in the first attempt as per protocol.
|
Time taken for successful placement
|
|
Number of Patients Who Required Multiple Attempts.
Time Frame: Time taken for intubation
|
The number of repeated attempts required for successfully placing the device.
Each device was given a chance of 3 attempts if still unsuccessful after 3 attempts another device was placed.
|
Time taken for intubation
|
|
Leak Pressures
Time Frame: Duration of surgery
|
The maximum leak pressure attained for each device.
|
Duration of surgery
|
|
Post Operative Morbidity
Time Frame: 2 hrs and 24 hrs after surgery
|
We followed the patients 2 and 24 hours after the surgery for sore throat, hoarseness and dysphagia.The numbers represented here are the number of patients who reported sore throat at 2 hrs and after 24 hrs as per the protocol.
|
2 hrs and 24 hrs after surgery
|
|
Number of Failed Cases
Time Frame: Time taken for successful intubation
|
We calculated the number of failed cases.
As per protocol, that is number of patients in whom successful intubation was not achieved with the assigned device after 3 attempts.
|
Time taken for successful intubation
|
Collaborators and Investigators
Study record dates
Study Major Dates
Study Start
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimate)
Study Record Updates
Last Update Posted (Estimate)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- HSC-MS-04-254
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.