The GORE Flow Reversal System, manufactured by W. L. Gore & Associates, Inc., was developed as a proximal occlusion device to reverse the flow of blood in the carotid artery. It is designed to achieve embolic protection prior to crossing the lesion in the majority of cases in order to minimize the possibility of an adverse event occurrence.
The objective of this study is to assess the safety and effectiveness of the GORE Flow Reversal System when used to provide embolic protection during Carotid Artery Stent (CAS) procedures. Subjects diagnosed with carotid stenosis requiring revascularization and are at high risk for adverse events from CEA are eligible to participate.
Study Type
Enrollment (Actual)
Phase
- Phase 3
Contacts and Locations
Study Locations
-
-
New York
-
Buffalo, New York, United States, 14209
- Millard Fillmore Gates/Univ. of Buffalo
-
-
Ohio
-
Cleveland, Ohio, United States, 44195
- Cleveland Clinic Foundation
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Carotid stenosis requiring revascularization and indicating either symptomatic status, with carotid stenosis ≥ 50% OR asymptomatic status with carotid stenosis ≥ 80%
- Target lesion is located in one of the following:(a) internal carotid artery (ICA) (b) bifurcation (c) common carotid artery (CCA) proximal to the bifurcation
- At Anatomic risk for adverse events from CEA (e.g. restenosis after a prior CEA) OR at Co-morbid risk for adverse events from CEA (e.g., unstable angina with ECG changes)
Exclusion Criteria:
- Recent surgical procedure within 30 days before or after the stent procedure
- Uncontrolled sensitivity to contrast media
- Renal Insufficiency
- Recent evolving, acute stroke within 21 days of study evaluation
- Myocardial infarction within 72 hours prior to stent procedure
- History of a prior major ipsilateral stroke with residual neurological deficits likely to confound the neurological assessments (e.g., NIHSS)
- Neurological deficits not due to stroke likely to confound the neurological assessments (e.g., NIHSS)
Angiographic Exclusion Criteria:
- Isolated ipsilateral hemisphere leading to subject intolerance to reverse flow
- Total occlusion of the ipsilateral carotid artery
- Pre-existing stent in the ipsilateral carotid artery OR the contralateral carotid artery that extends into the aortic arch
- Presence of a filling defect, thrombus, occlusion or "string sign" in the target vessel
- Severe lesion calcification restricting stent deployment
- Carotid stenosis located distal to target stenosis that is more severe than target stenosis
- > 50% stenosis of the CCA proximal to target vessel
- Known mobile plaque in the aortic arch
Study Plan
How is the study designed?
Design Details
- Primary Purpose: TREATMENT
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
EXPERIMENTAL: GFRS Pivotal Subjects
All non-training subjects using the GORE Flow Reversal System for embolic protection during carotid artery stenting (all subjects other than first two subjects accounted for in Training Cases).
|
Carotid artery angioplasty and stenting with embolic protection
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Composite Major Adverse Event (MAE) Rate
Time Frame: Treatment through 30-day visit window
|
Number of participants with one or more Major Adverse Event (death, stroke, myocardial infarction, and/or transient ischemic attack (TIA)) through the 30-day follow-up (non-hierarchical; MAE adjudicated by independent Clinical Events Committee)
|
Treatment through 30-day visit window
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Flow Reversal System Technical Success
Time Frame: Procedure
|
Number of participants with Technical Success using the GORE Flow Reversal System (system deployed and utilized during stenting procedure)
|
Procedure
|
|
Flow Reversal System Success
Time Frame: Procedure
|
Number of participants where the GORE Flow Reversal System was delivered, placed, reverse flow was established, and the balloon sheath and wire retrieved as outlined in the Instructions for Use without causing any adverse events during the procedure.
|
Procedure
|
|
Stent Success
Time Frame: Procedure
|
Number of participants where the FDA-approved stent was successfully delivered, deployed,and delivery system removed with an attainment of < 50% residual stenosis following stent placement, as assessed by the angiographic core laboratory.
|
Procedure
|
|
Clinical Success
Time Frame: 24-48 Hours Post-Procedure
|
Number of participants with Flow Reversal System and Stent Success in the absence of death, emergency endarterectomy, repeat percutaneous transluminal angioplasty (PTA)/thrombolysis of the target vessel, stroke, or myocardial infarction (MI), as determined by the Clinical Events Committee (CEC).
|
24-48 Hours Post-Procedure
|
|
Patency at 30 Days
Time Frame: Treatment through 30-day visit window
|
Number of participants with less than 50% restenosis as determined by carotid duplex ultrasound core laboratory at 30 days post-procedure.
|
Treatment through 30-day visit window
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Daniel Clair, M.D., The Cleveland Clinic
- Principal Investigator: L. N. Hopkins, M.D., Millard Fillmore Gates/Univ. of Buffalo
Publications and helpful links
General Publications
- Parodi JC. Re: is flow reversal the best method of protection during carotid stenting? J Endovasc Ther. 2005 Jun;12(3):414-5. doi: 10.1583/05-1610L.1. No abstract available.
- Parodi JC, Schonholz C, Parodi FE, Sicard G, Ferreira LM. Initial 200 cases of carotid artery stenting using a reversal-of-flow cerebral protection device. J Cardiovasc Surg (Torino). 2007 Apr;48(2):117-24.
- Parodi JC, Schonholz C, Ferreira LM, Mendaro E, Ohki T. "Seat belt and air bag" technique for cerebral protection during carotid stenting. J Endovasc Ther. 2002 Feb;9(1):20-4. doi: 10.1177/152660280200900104.
Study record dates
Study Major Dates
Study Start
Primary Completion (ACTUAL)
Study Completion (ACTUAL)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
Study Record Updates
Last Update Posted (ESTIMATE)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
- NPS 05-05
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.