Intra-operative Measurements to Predict the Position of the Intraocular Lens Post-operatively

May 29, 2013 updated by: Prim. Prof. Dr. Oliver Findl, MBA

Predictability of the IOL Position Using an Intra-operative OCT

Refractive outcome after cataract surgery mainly depends on the prediction of the intraocular lens that is implanted in the eye during surgery.

Aim of this study is to measure the position of the lens capsule during surgery and to use this measurements to improve post-operative refractive outcomes.

Study Overview

Status

Completed

Conditions

Detailed Description

During the last decades the refractive outcome after cataract surgery improved significantly.

The total prediction error in IOL power calculation (and therefore in the refractive outcome) can be divided into 3 main parameters:

  • Axial eye length (in mm)
  • Corneal power (in dioptres)
  • Estimation of post-operative anterior chamber depth (ACD) (in mm)

Since the introduction of optical biometry (IOLMaster, Carl Zeiss Meditec AG, Jena, Germany), as a reliable non-contact measurement of the axial eye length the influence of the error of axial length measurement on the refractive error decreased from over 50% (when measured with applanation ultrasound) to 36%. The mean error of corneal power measurement is approximately 22%.

These results show that the estimation of the post-operative intra-ocular lens (IOL) position and therefore the estimated anterior chamber depth (ACD) is nowadays the main source of error (35%to 42%) in IOL power calculation and therefore for the refractive outcome of the patients after cataract surgery.

Early IOL power calculation formulas, such as the Binkhorst I formula, used a fixed ACD value to predict the position of the IOL, but the refractive results were not appropriate, because the post-operative position of the IOL varied significantly between patients. Later observations showed a correlation between the axial eye length and the post-operative ACD (longer=more myopic eyes showed a larger ACD post-operatively). These correlations were taken into account in later developed formulas (such as the Binkhorst II formula).

Olsen et al. measured the post-operative ACD and substituted the predicted post-operative ACD with the true, post-operative ACD in each case. The result after correcting the IOL position was a highly accurate IOL power calculation, where no fudge factors were needed.

Nowadays the pre-operatively measured ACD is taken into account for several IOL power calculation formulas, such as the Haigis formula, the Holladay II formula and the Olsen formula.

However, this new generation of formulas uses the pre-operative ACD, without considering the thickness of the crystalline lens. The ACD is measured as the distance between the anterior surface of the cornea (anatomically correct would be the posterior surface of the cornea, but in an optical context, as in IOL power calculations, the anterior surface is used) and the anterior surface of the crystalline lens . Therefore the thickness of the crystalline lens has a significant impact on the predicted post-operative position of the IOL. This parameter was first taken into account by Olsen and later modified by Norrby.

It should be mentioned that IOL power calculations developed from theoretical calculations based on Gaussian optics to regression formulas, such as the SRK formula 11 that uses retrospective data of a large number of patients. Nowadays ray tracing is available that uses a numerical solution to calculate the IOL power.

All these findings suggest that a proper measurement of the position and the size of the crystalline lens as well as of the lens capsule after removing the crystalline lens is necessary to improve IOL power calculation.

Recently a device was introduced that allows measurements of the crystalline lens as well as the lens capsule itself after removing the crystalline lens of cataract patients intra-operatively. This device uses optical coherence tomography (OCT) technology to create high resolution B-scans (=images) of the anterior segment of the eye. The OCT was shown to be highly reproducible for ACD measurements pre-operatively and small changes of the IOL/crystalline lens can be detected.

The intra-operative OCT may allow measurements of the crystalline lens, of the lens capsule and furthermore of the position of the IOL intra-operatively. Therefore it may be possible for the first time, to directly observe the correlation of the position and size of the crystalline lens to the IOL position intra-operatively.

Number of subjects In total, 50 eyes of 50 subjects will be included.

  • Standard eyes (IOL power 18 - 23 D): 30 eyes
  • Long (myopic) eyes (IOL power < 18 D) - 10 eyes
  • Short (hyperopic) eyes (IOL power > 23 D) - 10 eyes

Study Visits On the day of pre-operative examination, the patient will undergo a full ophthalmic assessment and routine biometry will be performed for axial length measurement and Keratometry (IOLMaster, Carl Zeiss Meditec AG, Jena, Germany). Furthermore pre-operatively the ACD and lens thickness (LT) will be measured (ACMaster, Carl Zeiss Meditec AG, Jena, Germany).

Surgery is performed in topical anaesthesia. The standard preoperative therapy is tropicamide 1% gtt, phenylephrine 2.5% gtt, cyclopentolate 1% gtt. An on-axis self-sealing incision, injection of viscoelastic substance, capsulorhexis, phacoemulsification, irrigation/aspiration of cortical material are performed as standard procedure. After measurement, the IOL will be implanted using the dedicated injector system.

Intra-operative study-related measurements:

OCT scans will be performed at 4 different stages intra-operatively:

  1. At the beginning of the surgery
  2. After removing the natural crystalline lens with phakoemulsification and irrigation/aspiration (I/A). The infusion handpiece of the I/A set (that is used routinely) will be placed into the paracentesis and the bottle height will be adjusted to control the pressure in the anterior chamber. It will be set to result in an estimated pressure of approximately 20mmHg. Therefore a hydraulic table with memory function will be used that can be set at exactly the same height for each patient and the infusion bottle will be placed at a height of 27cm above the eye (27.2cmH2O = 20mmHg). Then an OCT scan will be performed.
  3. Then ophthalmic viscosurgical device (OVD) is inserted and a capsular tension ring (CTR) will be implanted. Therefore the OVD is irrigated and aspirated and the measurement repeated.
  4. Afterwards the IOL is implanted and the viscoelastic is removed.

Outcome variables

Main outcome variable:

  • Intra-operative posterior capsule position with CTR in place Additional outcome variable
  • Posterior capsule position in phakic eyes
  • Posterior capsule position intra-operatively without CTR
  • Comparison of posterior capsule position of eyes with different axial eye length

Study Type

Observational

Enrollment (Actual)

70

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

21 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Probability Sample

Study Population

patients who are sceduled for cataract surgery

Description

Inclusion Criteria:

  • Cataract
  • Age 21 and older
  • written informed consent prior to surgery

Exclusion Criteria:

  • Relevant other ophthalmic diseases such as: pseudoexfoliation, glaucoma, traumatic cataract, corneal scars, and other co-morbidity
  • In case of pregnancy (pregnancy test will be taken preoperatively in women of reproductive age)

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Correlation of intra-operative lens capsule measurements and the post-operative lens position
Time Frame: 3 months
Aim of this outcome parameter is to detect, if intra-operative measurements (with an optical coherence tomogrophy system) help to detect the position of the artificial lens post-operatively
3 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

December 1, 2010

Primary Completion (ACTUAL)

December 1, 2012

Study Completion (ACTUAL)

March 1, 2013

Study Registration Dates

First Submitted

May 26, 2013

First Submitted That Met QC Criteria

May 29, 2013

First Posted (ESTIMATE)

June 4, 2013

Study Record Updates

Last Update Posted (ESTIMATE)

June 4, 2013

Last Update Submitted That Met QC Criteria

May 29, 2013

Last Verified

May 1, 2013

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Cataracts

3
Subscribe