Hyperpolarized Xenon Gas MR Imaging in NSCLC Radiotherapy

May 23, 2022 updated by: Oxford University Hospitals NHS Trust

A Study to Determine Regional Lung Function in Patients With Non-small Cell Lung Cancer (NSCLC) Undergoing Radiotherapy Using Hyperpolarized Xenon Gas MR Imaging

Lung cancer is the second most commonly diagnosed cancer in the United Kingdom, accounting for 22% of cancer deaths. The main treatments for lung cancer are surgery, radiotherapy or chemoradiotherapy. Current methods, for assessing lung function in lung cancer patients i.e. spirometry and gas transfer are inadequate. We aim to develop a new technique capable of describing regional lung abnormality using hyperpolarized xenon gas MRI.

The study will involve 50 patients diagnosed with lung cancer considered suitable for radical radiotherapy or chemoradiotherapy. Participants will be offered hyperpolarized Xe129 MR at baseline, two weeks after commencement of radiotherapy schedules and four followup visits over one year posttreatment.

Patients will undertake extensive study measures at baseline and followup visits, including chest CT scans, ventilation/perfusion nuclear medicine scans, gadolinium enhanced MRI scans, pulmonary function tests, breathlessness scores, radiotherapy induced lung toxicity assessments and exercise testing. Participation in these full tests takes a day, allowing patients time to rest between tests and allowing for a period of observation following the final hyperpolarized xenon scan.

The investigators will correlate baseline hyperpolarized Xe129 MR imaging with spirometry and breathlessness scores to determine if tolerance for radiotherapy is better predicted by hyperpolarized Xe129 MR imaging. The investigators will evaluate changes in hyperpolarized Xe129 MR imaging before and after radiotherapy (RT) to determine if it provides better monitoring of response compared with spirometry.

The study will take place at the Churchill Hospital, Oxford University Hospitals National Health Service Trust and will be funded by the National Institute for Health Research Oxford Biomedical Research Centre. Hyperpolarized Xe129 MR imaging has the potential to inform individual suitability for radiotherapy schedules better than the investigations used currently. In addition, hyperpolarized Xe129 MR imaging has the potential for better monitoring of treatment response and improved detection of radiation induced lung injury, invaluable to treating patients with radiation induced injury.

Study Overview

Status

Completed

Detailed Description

Survival rates for lung cancer are poor. One year survival rate in the United Kingdon for males is 27% and for females 30%, falling to less than 10% at five years. Prognosis for lung cancer is so poor because over two thirds of patients are diagnosed at a late stage when curative treatment is not possible. Early diagnosis and assessment of tolerance for curative treatment would make a significant difference to survival rates.

Histologically, approximately 80% of lung cancer is nonsmall cell lung cancer (NSCLC). The main curative treatment for NSCLC is surgery. Radical radiotherapy and chemoradiotherapy are other potentially curative treatments. These are suitable for patients who present with localized tumours that are surgically unresectable due to involvement of critical local structures or medically inoperable disease due to advanced age or comorbidities. Radiotherapy aims to deliver a high tumouricidal dose to the tumour without damaging the surrounding normal lung tissue. A high dose of radiotherapy improves local control but incurs a risk of inducing toxic effects in the normal lung tissue. If radiationinduced lung toxicity could be better predicted and monitored, radical radiotherapy could be tailored to the individual, which could also have the benefit of avoiding or reducing radiation dose to functional lung tissue.

Currently assessment of patients for radiotherapy involves lung function measurements to provide a clinical indicator as to whether or not the patient would tolerate treatment and maintain sufficient functioning lung posttreatment to continue with activities of daily living without significant impairment. The current gold standard for assessment of lung function is spirometry and gas transfer. Spirometry and gas transfer measure global lung function but provides no information about the different regions of the lung or regarding the support 'framework' of the lung, the parenchyma.Changes in lung function as measured by spirometry or gas transfer do not coherently correlate with symptom severity or reflect a decline in patient health. This weak relationship is probably because the lung is a complex regional organ where localized disturbances of a variety of factors including gas flow (ventilation), blood flow (perfusion) and gas transfer all combine to impair respiratory function.

To address these issues we aim to use hyperpolarized xenon gas (Xe129) magnetic resonance imaging (MRI)and computed tomography (CT)to describe detailed regional and structural lung abnormality in patients with NSCLC. The investigators will correlate this technique with baseline spirometry and dyspnoea scores to determine if respiratory tolerance of radiotherapy is better predicted by hyperpolarized Xe129 MR imaging. The investigators will compare hyperpolarized Xe129 MRI with standard imaging(nuclear medicine scans). The investigators will also evaluate changes in hyperpolarized Xe129 MR imaging before, during and after radiotherapy to determine if it provides improved assessment of radiationinduced lung injury. MRI has advantage of being free from ionizing radiation making it safe and practical for diseases like lung cancer where repeated followup scans are necessary. MR imaging has an enhanced speed of image acquisition compared with CT and lung scintigraphy and offers the potential of dynamic assessment of lungs during respiration. In conventional MRI, the signal originates principally from the protons in water molecules of tissues. Therefore conventional MRI has limited use in respiratory disease because the lung has a very low density of protons, instead being largely composed of air spaces that do not generate MR signal. Hyperpolarised noble gases can resolve this problem. Xenon (Xe129) is an unreactive or inert noble gas. It has a nuclear spin of ½ enabling use in MR imaging to generate a signal. Xe129 is hyperpolarized, that is to say that nuclear spin within the atoms is increased. Hyperpolarization increases the MR signal enabling the Xe129 gas to show up on the MR scan. In portions of the lung that have good airflow, the hyperpolarized Xe129 gas will show up more and be seen more quickly. In addition Xe129 readily dissolves in blood where it emits different MR signal characteristics. This property may be exploited to regionally quantify both ventilation and perfusion within the lung providing a comprehensive assessment of lung function. The need for improved functional imaging to identify preexisting lung disease and predict respiratory tolerance of patients with NSCLC for radiotherapy treatment is clear. Hyperpolarized Xe129 MR imaging has the potential to inform individual suitability for radiotherapy schedules better than the investigations used currently. In addition improved functional imaging is required to monitor treatment response and enable treatment regimes to be tailored to the individual. Hyperpolarized Xe129 MR imaging offers the potential of improved detection of radiationinduced lung injury, invaluable to treating patients with radiation induced injury. It may also provide information that would allow RT to be planned in such a way as to reduce the risk of patients developing radiationinduced lung toxicity (RILT).

The need for improved functional imaging to identify preexisting lung disease and predict respiratory tolerance of patients with NSCLC for radiotherapy treatment is clear. Hyperpolarized Xe129 MR imaging has the potential to inform individual suitability for radiotherapy schedules better than the investigations used currently. In addition improved functional imaging is required to monitor treatment response and enable treatment regimes to be tailored to the individual. Hyperpolarized Xe129 MR imaging offers the potential of improved detection of radiationinduced lung injury, invaluable to treating patients with radiation induced injury. It may also provide information that would allow RT to be planned in such a way as to reduce the risk of patients developing radiationinduced lung toxicity (RILT).

Study Type

Interventional

Enrollment (Actual)

22

Phase

  • Phase 2

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • England
      • Oxford, England, United Kingdom, OX3 7LE
        • Oxford University Hospitals NHS Trust

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Participant is willing and able to give informed consent for participation in the trial
  • Male or Female, aged 18 years or above
  • Histologically verified NSCLC
  • Patients with any stage NSCLC where radical radiotherapy (with either conventionally fractionated treatment or with stereotactic body radiotherapy (SABR)) or chemoradiotherapy (concurrent or sequential schedule) is considered appropriate
  • WHO performance status 0-2
  • Able (in the Investigators opinion) and willing to comply with all study requirements

Exclusion Criteria:

  • Inability to give written informed consent
  • Female participant who is pregnant, lactating or planning pregnancy during the course of the trial
  • Previous radiotherapy to the chest
  • The presence of another condition where the disease itself or treatment may interfere with the study endpoints
  • Any psychological, familial, sociological or geographical condition potentially hampering compliance with the study protocol and follow-up schedule
  • Inability to lie flat for imaging
  • Contraindications to MRI examination including indwelling pacemaker, non-MRI compatible metallic implant, severe claustrophobia, intra-ocular foreign body
  • Contraindications for gadolinium enhanced lung MRI scan - known hypersensitivity/allergy to the injection of MultiHance (contains gadobenate dimeglumine and small quantities of benzyl alcohol) that is given as part of this scanning or an adverse reaction to an injection given during previous MRI scanning, severe renal impairment
  • Contraindications for ventilation/perfusion nuclear medicine scanning - known hypersensitivity to albumin or preference to avoid blood donation product
  • Epilepsy requiring on-going medical treatment, or a seizure within the past year

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: 129 Xenon MR Imaging
Xenon gas is inhaled immediately before acquisition of an MR image to enable the lung structure to be seen.
The xenon gas is inhaled immediately before acquisition of an MR image to enable the lung structure to be seen.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Number of Participants With a Change From Baseline in Ventilation Map Using Hyperpolarized Xe-129 MR Imaging
Time Frame: Mid-point of radiotherapy - varies depending on the duration of treatment prescribed, between 1 week to 2 months from the baseline scan (range: 7 days to 60 days). For example, for 2 weeks of radiotherapy, this would be at 1 week post-baseline.
Number of participants with a change from baseline in ventilation map using hyperpolarized Xe-129
Mid-point of radiotherapy - varies depending on the duration of treatment prescribed, between 1 week to 2 months from the baseline scan (range: 7 days to 60 days). For example, for 2 weeks of radiotherapy, this would be at 1 week post-baseline.

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Number of Participants With a Change in Ventilation and ADC Maps Using Hyperpolarized Xe-129 MR Imaging From Baseline to 3 Months Post Radiotherapy Completion
Time Frame: 3 months after completion of treatment
Number of participants with a change in ventilation MRI acquired for 5 patients, 3 months after treatment completion ADC not acquired in this study
3 months after completion of treatment
Correlation Between Change in Ventilation/ ADC Maps Using Hyperpolarized Xe-129 MR Imaging and Change in Lung Function From Baseline to Follow-up (During Treatment)
Time Frame: Mid-point of radiotherapy - varies depending on the duration of treatment prescribed, between 1 week to 2 months from the baseline scan - Range: 7-60 days.) For example, for 2 weeks of radiotherapy, this would be at 1 week post-baseline.
Correlation between change in ventilation or ADC maps using hyperpolarized Xe-129 MR imaging and change in lung function from baseline to follow-up (during treatment), acquired at the mid-point of treatment.
Mid-point of radiotherapy - varies depending on the duration of treatment prescribed, between 1 week to 2 months from the baseline scan - Range: 7-60 days.) For example, for 2 weeks of radiotherapy, this would be at 1 week post-baseline.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Fergus V Gleeson, MB BS, FRCP, Professor of Radiology

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

April 23, 2014

Primary Completion (Actual)

December 31, 2020

Study Completion (Actual)

December 31, 2020

Study Registration Dates

First Submitted

May 21, 2014

First Submitted That Met QC Criteria

May 29, 2014

First Posted (Estimate)

May 30, 2014

Study Record Updates

Last Update Posted (Estimate)

February 23, 2023

Last Update Submitted That Met QC Criteria

May 23, 2022

Last Verified

September 1, 2021

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Non-small Cell Lung Cancer

Clinical Trials on Inhalation of hyperpolarized xenon gas

3
Subscribe