- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT04175457
The Acute Effects of E-cigarette Inhalation on Vascular Function, Microcirculation and Thrombosis
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Twenty-two healthy, female and male occasional smokers or snus users (age 18-55, 10 cigarettes per month, 10 pouches of snus per month) will be included. Research subjects are required to refrain from intake of alcohol and caffeine during at least 24 hours prior to the exposure. Tobacco usage (including Swedish moist snuff) or e-cigarette usage is not permitted within 7 days prior to exposure.
All subjects have to complete a normal health declaration.
In a randomized cross-over fashion, all subjects will inhale vapor (30 puffs for 30 minutes) from one electronic cigarette, eVic-Primo SE (Shenzhen Joyetech Co., Ltd., China). in a specially prepared room with adequate ventilation.
There are plenty e-liquid manufacturers and distributors on the market. Independent content analysis showed that nicotine variation across e-liquid batches is low and that the amount of nicotine as stated by the manufacturer often is correct. E- liquid without any flavourings (Valeo laboratories GmbH, Germany) without and with nicotine (19 mg/ml) will be used. Content analysis is free available on the manufacturers homepage (http://www.e-liquid-wholesale.com). A third-generation EC is used with settings (Temperature 230°C, Effect 32 W, Resistance 0,20 Ω).
Research subjects are required to refrain from intake of alcohol during at least 24 hours prior to the exposure sequences, as well as caffeine for 12 hours. The two occasions will be separated by at least one week. Subjects rest for 15 minutes preceding the exposure.
Following the initial 15 minute rest the measurements for various cardiovascular endpoints will be performed at baseline and up to two hours following both exposures. This will be done with the following methods:
Measurement of vascular function
Photopletysmography (PPG) Arterial stiffness is an independent measure of vascular damage and risk, and is best assessed with the gold-standard technique pulse-wave velocity (PWV). However this method is technically demanding requiring special equipment (like SphygmoCor) and educated study personell. Finger photoplethysmography, however, is potentially providing the same information as PWV, and is ideal for continous measurment of arterial stiffness.
pulse propagation time (PPT), the interval from the systolic to the diastolic peak of the pulse wave. PPT is an upcoming marker for arterial stiffness and vascular aging. At the same time ECG and heat sounds by a microphone will be recorded making the analysis easier to validate.
Microcirculation Iontophoresis and laser speckle contrast imaging (LSCI) Microcirculation is assessed by a non-invasive method where two substances (acetylcholine and nitroprusside) is applied in a small chamber (0,5 ml) on the surface of the skin. Changes in microcirculation is measured with laser Doppler. The method is completely harmless and pain free. An uncommon but plausible side effect is local temporary skin rash.
For every heart-beat a pressure wave is generated reaching even the most peripheral parts of the body. By measuring changes in light absorption it is possible to assess distensions (even very small) in the peripheral arteries and arterioles in the subcutaneous tissue, in for example the tip of the finger. Microcirculation can also be measured by laser speckle contrast imaging (LSCI) which is a non-invasive completely pain free method for assessing microcirculation of the skin.
Blood pressure A semi-automatic oscillometric sphygmomanometer will be used to measure blood pressure and heart rate.
Blood sampling Blood samples will be drawn into test tubes containing 1/10 0.129 M sodium citrate, EDTA and serum at baseline, at 0 hour, 1 hour and 2 hours after exposure. Plasma is later collected after centrifugation at 2 000g for 20 min in room temperature (RT) and then frozen at -70°C until analysis.
Measurement of thrombus formation (T-TAS) T-TAS® (Total Thrombus-formation Analysis System) is a means of assessing thrombus formation during variable flow conditions using a small blood sample.
Measurement of cotinine Levels of cotinine will be measured in serum using a commercial available ELISA technique.
Through direct microscopy of the capillaries of the nail bed of one of the fingers capillary blood flow can be assessed (capillary blood cell velocity, CBV, mm/s). This is a completely pain free and non-invasive method that takes about 15 minutes to perform.
Measurement of MV Plasma is thawed and centrifuged at 2000g for 20 minutes at RT. The supernatant is then re- centrifuged, at 13 000g for 2 minutes at RT. 20 μl of sample is incubated for 20 minutes in dark with phalloidin-Alexa-660 (Invitrogen, Paisley, UK), lactadherin-FITC (Haematologic Technologies, Vermont, USA), CD42a-PE (Platelet-MP (PMP), BD, Clone Alma-16), CD45- PC7 (Leukocyte-MV (LMV), Beckman Coulter, Dublin, Ireland) and CD144-APC (Endothelial-MV (EMV), AH diagnostics, Stockholm, SWE). PMVs are also labeled with CD154-PE (CD40L, abcam, Cambridge, UK) and EMVs with CD62E (E-selectin, Beckman Coulter, Dublin, Ireland). MVs are measured by flow cytometry on a Beckman Gallios instrument (CA, USA). The MV-gate is determined using Megamix beads (BioCytex, Marseille, France), which is a mix of beads of with diameters of 0.5 μm, 0.9 μm and 3.0 μm, respectively. MVs are defined as particles less than 1.0 μm in size, negative to phalloidin (in order to exclude cell membrane fragments) and positive to lactadherin. Conjugate isotype- matched immunoglobulin (IgG1-FITC, IgG1-PE, IgG1-APC and IgG1- PC7) with no reactivity against human antigens is used as a negative control to define the background noise of the cytometric analysis. The absolute number of MVs is calculated by means of the following formula: (MV counted x standard beads ⁄ L) ⁄ standard beads counted, (FlowCount, Beckman Coulter).
To determine whether MVs are released due to activation or apoptosis MVs are labeled with SYTO 13. SYTO 13 (Molecular Probes) is cell permeable and has a high fluorescent yield when bound to DNA or RNA. Our hypothesis is that MVs released from apoptotic cells express more DNA or RNA.
Pro-coagulant effect of MVs In vitro experiments are performed to investigate the influence of MVs on thrombin generation, and the relative contribution of the negatively charged surface provided by MVs. Briefly plasma samples are thawed and after the centrifugation steps described above we further centrifuge the samples (twice 21 000g in 45 min, RT) to obtain an MV enrich pellet. The pellet is then added to commercial plasma (Haemochrom, Diagnostica, Essen, Germany) with no addition of TF or phospholipids. Thrombin generation in plasma is determined by using the calibrated automated thrombogram (CAT) as originally described by Hemker et al. The calculated area under the curve represents the total amount of thrombin generated over time and is called the endogenous thrombin potential (ETP). Time to the start of thrombin generation (lag time), maximal concentration of thrombin generation (peak thrombin) and time to maximal thrombin generation (time to peak thrombin) is also assessed in CAT analysis.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Stockholm
-
Danderyd, Stockholm, Sweden, 18288
- Institutionen för kliniska vetenskaper, Danderyds sjukhus
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Normal health declaration
Exclusion Criteria:
- Any form of cardiovascular disease
- Any form of pulmonary disease like asthma or COPD
- Any form of systemic or chronic disorder like rheumatologic or metabolic diseases. - Symptoms of infection or inflammation within 4 weeks of the study
- Pregnancy
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Double
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
---|---|
Experimental: e-cigarette inhalation with nicotine
inhalation of e-cigarette vapor with nicotine for 30 minutes.
|
E-cigarette inhalation for 30 minutes using e-cigarette with and without nicotine
|
Active Comparator: e-cigarette inhalation without nicotine
inhalation of e-cigarette vapor without nicotine for 30 minutes.
|
E-cigarette inhalation for 30 minutes using e-cigarette with and without nicotine
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
microcirculation
Time Frame: change from baseline and 1 hour following exposures
|
Iontophoresis and laser speckle contrast imaging (LSCI), Measurement of capillary blood flow (Capiflow), GlycoCheck system
|
change from baseline and 1 hour following exposures
|
thrombosis (total thrombus formation analysis system)
Time Frame: change from baseline, 30 minutes and 2 hour following exposures
|
T-TAS (area under the curve, flow pressure change)
|
change from baseline, 30 minutes and 2 hour following exposures
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
---|---|---|
arterial stiffness
Time Frame: change from baseline up to 3 hours following exposures
|
Photopletysmography (PPG), arteriographyTensioMed, Budapest, Hungary,Sphygmocor AtCor Medical, EndoPAT (Itamar)
|
change from baseline up to 3 hours following exposures
|
Microvesicles
Time Frame: change from baseline, 30 minutes and 2 hour following exposures
|
microvesicles of leukocyte, endothelial and platelet origin (MVs/microliter)
|
change from baseline, 30 minutes and 2 hour following exposures
|
NETs(neutrophil extracellular traps)
Time Frame: change from baseline, 30 minutes and 2 hour following exposures
|
blood levels of H3Cit using ELISA
|
change from baseline, 30 minutes and 2 hour following exposures
|
capillary microscopy
Time Frame: change from baseline to 1 hour following exposures
|
capillary blood cell velocity, CBV, mm/s
|
change from baseline to 1 hour following exposures
|
Collaborators and Investigators
Sponsor
Collaborators
Investigators
- Study Director: Erik Näslund, MD, Prof, Karolinska Institutet, Danderyd Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 2018/2721-31/1
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Thrombosis
-
Università degli Studi dell'InsubriaOttawa Hospital Research InstituteUnknownPortal Vein Thrombosis | Mesenteric Vein Thrombosis | Splenic Vein ThrombosisCanada, Italy
-
University of MaltaUniversità degli Studi dell'InsubriaRecruitingCerebral Vein Thrombosis | Renal Vein Thrombosis | Retinal Vein Thrombosis | Splanchnic Vein Thrombosis | Ovarian Vein ThrombosisThailand, Spain, United States, Italy, Slovenia, France, Israel, Canada, Malta, Netherlands
-
Capital Medical UniversityBeijing Municipal Science & Technology CommissionNot yet recruitingCerebral Venous Sinus Thrombosis | Deep Cerebral Vein Thrombosis | Cortical Vein Thrombosis
-
University of AlbertaSanofi; Edmonton Civic Employees Research FundTerminatedPortal Vein Thrombosis | Splenic Vein ThrombosisCanada
-
Academic and Community Cancer Research UnitedNational Cancer Institute (NCI)CompletedDeep Vein Thrombosis | Venous Thromboembolism | Pulmonary Embolism | Malignant Neoplasm | Portal Vein Thrombosis | Metastatic Malignant Neoplasm | Cerebral Vein Thrombosis | Renal Vein Thrombosis | Gonadal Thrombosis | Hepatic Thrombosis | Mesenteric Thrombosis | Splenic ThrombosisUnited States
-
Assiut UniversityNot yet recruitingPortal Vein Thrombosis
-
Azienda Ospedaliera Universitaria PoliclinicoCompletedDeep Vein ThrombosisItaly
-
University of OklahomaPfizerCompleted
-
Fondazione Policlinico Universitario Agostino Gemelli...RecruitingSplanchnic Vein ThrombosisItaly
-
University Hospital, GenevaSunnybrook Health Sciences CentreNot yet recruitingDeep Vein Thrombosis
Clinical Trials on e-cigarette
-
IRCCS Azienda Ospedaliero-Universitaria di BolognaFondazione Salvatore MaugeriCompleted
-
University of OklahomaCompletedSmoking CessationUnited States
-
University of California, San FranciscoNational Institute on Drug Abuse (NIDA); National Institutes of Health (NIH); Roswell Park Cancer InstituteCompleted
-
University of California, Los AngelesTobacco Related Disease Research ProgramCompleted
-
Ohio State University Comprehensive Cancer CenterNational Cancer Institute (NCI); National Institutes of Health (NIH); University...CompletedNicotine Dependence | Smoking, Tobacco | Smoking, Cigarette | Exposure to Toxic AgentUnited States
-
Virginia Polytechnic Institute and State UniversityNational Cancer Institute (NCI); University of MinnesotaCompletedTobacco Use DisorderUnited States
-
University of Southern CaliforniaCompletedElectronic Cigarette Use | Cigarette Smoking | Cigarette Use, Electronic | VapingUnited States
-
GWT-TUD GmbHTerminated
-
Dartmouth-Hitchcock Medical CenterVinfen Corporation; Centerstone KentuckyCompletedSchizophrenia | Schizoaffective Disorder | Bipolar Disorder | Tobacco DependenceUnited States
-
Fordham UniversityMontefiore Medical Center; Dartmouth CollegeRecruitingTobacco Smoking | Psychiatric DisordersUnited States