Establishing a New Ultrasound Technique to Improve Assessment of Chronic Kidney Disease.

November 28, 2023 updated by: University of Nottingham

Validation of Contrast Enhanced Ultrasound (CEUS) for the Assessment of Renal Perfusion Using Renal Magnetic Resonance Imaging (MRI) in Chronic Kidney Disease (CKD

Blood flow to the kidneys is important in the development of kidney diseases. Currently we do not have ways of measuring and monitoring kidney blood flow for patients in real-time. This is a major barrier to investigation and management of acute kidney injury (AKI) and chronic kidney disease (CKD).

Kidney blood flow can be reliably measured using a specialised type of MRI scan, but this is expensive and difficult to do in people who are unwell. Contrast-enhanced ultrasound (CEUS) is a new technique, which uses a contrast containing microbubbles to measure blood flow. The benefits of this method are that it is relatively inexpensive, the contrast agents are not kidney-damaging and it can be done at the bedside.

We want to compare contrast enhanced ultrasound against the current best-measure of kidney blood flow, to see if it is giving accurate information about kidney blood flow. We will do this by doing both MRI and contrast enhanced ultrasound scans in people with chronic kidney disease and comparing the results.

Study Overview

Detailed Description

Renal perfusion, the delivery of oxygenated blood to kidney tissues, is relevant to a number of acute and chronic kidney diseases. Despite this, we do not have methods in current clinical practice to measure renal perfusion and monitor the response to supportive treatments in real time. This is a major barrier to investigation and management of acute kidney injury (AKI) and chronic kidney disease (CKD).

The current non-invasive gold standard technique for renal perfusion measurement is arterial-spin labelling magnetic resonance imaging (ASL-MRI), which has been validated against other measures of perfusion, including contrast agent-based methods. However, MRI has limitations including high cost, and logistical barriers. Therefore, validation of a bed-side measurement tool for renal perfusion would be of significant clinical importance.

This proposal aims to validate CEUS renal cortical perfusion measurement by comparison with quantifiable ASL-MRI parameters of renal microvascular perfusion in individuals with CKD.

TRIAL REGIMEN

All interventions outlined below are for the purposes of research, not usual care.

Study day:

All participants will attend fasted for preceding 2 hours. Demographic details and medical history will be recorded. The patient's concomitant medications which form part of their usual care will be recorded. These will not be adjusted.

Results of blood and urine tests that are collected as part of clinical care will be recorded.

Participants will undergo two scanning sessions, the first using renal MRI at the Sir Peter Mansfield Imaging Centre (SPMIC) to provide a quantitative measure of renal perfusion, and the second to provide the comparator measure of renal perfusion using CEUS performed at Royal Derby Hospital.

Outcomes:

MRI derived perfusion variables: peak time, and peak signal intensity (SI) will be obtained from time intensity curves.

Mean flow velocity (cm/s), cross-sectional area of the lumen (mm2), and hence bulk renal blood flow (ml/s)

CEUS derived perfusion parameters: acoustic index (AU); mean transit time (seconds); perfusion index, which is the ratio of AI to mTT; and wash-in rate (seconds)

Study Type

Interventional

Enrollment (Estimated)

10

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • CKD 3b or CKD4
  • Ability to give informed consent

Exclusion Criteria:

  • Autosomal dominant polycystic kidney disease
  • Solid organ transplant
  • Pregnant women
  • Known allergy to Sonovue
  • Contraindications to MRI

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Participants with CKD having MRI and CEUS
10 participants with CKD will have an MRI scan and a contrast enhanced ultrasound scan. The two scans will be done within 7 days of each other.
Contrast enhanced ultrasound using Sonovue microbubble contrast
Arterial-spin labelling magnetic resonance imaging

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Correlation between ASL-MRI measures of cortical perfusion (ml/ 100g/min) and CEUS measures of renal microvascular blood flow.
Time Frame: MRI scan and contrast enhanced ultrasound scan to be performed within 7 days of each other.
The primary outcome will be the correlation between ASL-MRI measures of cortical perfusion (ml/ 100g/min) and CEUS measures of renal microvascular blood flow. As CEUS and ASL-MRI generate different units of measurement, correlations (rather than Bland-Altman analyses) will be used. We will define an ideal result as correlation coefficient r≥0.65, and adequate correlation coefficient r≥0.4.
MRI scan and contrast enhanced ultrasound scan to be performed within 7 days of each other.

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Repeatability of the CEUS measurements
Time Frame: 1 scan
Repeatability of markers of perfusion between 5 flash-reperfusion sequences taken during 1 scan session
1 scan
Correlation between global perfusion from PC-MRI corrected flow measures and CEUS
Time Frame: MRI scan and CEUS done within 7 days of each other
As CEUS and ASL-MRI generate different units of measurement, correlations (rather than Bland-Altman analyses) will be used. We will define an ideal result as correlation coefficient r≥0.65, and adequate correlation coefficient r≥0.4.
MRI scan and CEUS done within 7 days of each other
Correlation between kinetic time-intensity parameters of CEUS and time-resolved MRA
Time Frame: MRI scan and CEUS done within 7 days of each other
As CEUS and ASL-MRI generate different units of measurement, correlations (rather than Bland-Altman analyses) will be used. We will define an ideal result as correlation coefficient r≥0.65, and adequate correlation coefficient r≥0.4.
MRI scan and CEUS done within 7 days of each other

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Nick Selby, University of Nottingham

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

January 2, 2024

Primary Completion (Estimated)

February 2, 2025

Study Completion (Estimated)

February 2, 2025

Study Registration Dates

First Submitted

November 28, 2023

First Submitted That Met QC Criteria

November 28, 2023

First Posted (Estimated)

December 6, 2023

Study Record Updates

Last Update Posted (Estimated)

December 6, 2023

Last Update Submitted That Met QC Criteria

November 28, 2023

Last Verified

November 1, 2023

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Chronic Kidney Diseases

Clinical Trials on Contrast enhanced ultrasound scan

Subscribe