Detailní popis
The position of endotracheal tubes depends on the position of the patients. The change of the tube's position is known to influence the pressure of tube's cuff. The shape of the cuff (barrel-shaped versus tapered-shaped) may affect the tube's migration degree because of the difference of the frictional force.
The investigator try to compare the the cuff pressure after supine-to-lateral position change between barrel-shaped cuff and taper-shaped cuff.
Typ studie
Typ studie
Zápis (Očekávaný)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní kontakt
Studijní kontakt
- Jméno: Hyun-Chang Kim, MD
- Telefonní číslo: +821028862876
- E-mail: onidori1979@gmail.com
Studijní místa
-
-
-
Seoul, Korejská republika
- Seoul National University Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Patient scheduled for nephrectomy in lateral decubitus position
Exclusion Criteria:
- Pregnancy
- Patients with difficult airway
- Patients with neck motion disorder
- Patients with history of neck surgery
- Patients with history of oral and pharyngeal surgery
- Patients with body mass index > 35
- Patients without teeth
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Prevence
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Singl
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Aktivní komparátor: Barrel
Endotracheal tube with barrel-shaped cuff will be used during general anesthesia.
|
Barrel-shaped endotracheal tube will be used during general anesthesia.
|
|
Aktivní komparátor: Tapered
Endotracheal tube with tapered-shaped cuff will be used during general anesthesia.
|
Tapered-shaped tube will be used during general anesthesia.
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
The cuff pressure after supine-to-lateral position change
Časové okno: At 10 minutes after anesthetic induction
|
The cuff pressure will be measured after supine-to-lateral position change using the Manometer Portex®.
|
At 10 minutes after anesthetic induction
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
The distance from the tube to the carina
Časové okno: At 10 minutes after anesthetic induction
|
The distance from the tube to the carina will be measured using bronchoscopy after supine-to-lateral position change.
|
At 10 minutes after anesthetic induction
|
|
Complications related to endotracheal tube
Časové okno: At 0, 2, and 24 hours postoperatively
|
Complications related to endotracheal tube (sore throat, hoarseness, dysphagia and cough) will be measured as 0:none, 1:mild, 2:moderate, 3:severe at 0, 2, and 24 hours postoperatively.
|
At 0, 2, and 24 hours postoperatively
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Hee-Pyoung Park, PhD, Seoul National University of Hospital
Publikace a užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Začátek studia
Primární dokončení (Očekávaný)
Primární dokončení
Dokončení studie (Očekávaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- LateralTaperedCuff-phpkhc
- LateralCuff_SNUH
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .