Innovative Approaches to Assessment of Pain Control and Sedation in the NICU
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
This is a prospective, non-interventional study designed to assess noxious-specific neurophysiologic responses and clinical signs following procedural pain in infants requiring hospitalization in the neonatal intensive care unit (NICU) following elective surgery.
The main goal of the study is to develop a method that reliably quantifies the level of pain induced from clinically-required noxious procedures to infants hospitalized in the NICU. This method will use measures of neurophysiological, autonomic, and behavioral responses to non-noxious and clinically-required noxious stimuli in order to guide the pharmacological treatment of NICU patients with analgesic agents, sedatives and/or muscle relaxants.
The investigators hypothesize that resting state activity and physiological responses to noxious and non-noxious stimuli provide a more reliable assessment of the level of pain of infants hospitalized in the NICU compared to behavioral-based pain scores.
Typ studie
Typ studie
Zápis (Očekávaný)
Zápis
Kontakty a umístění
Studijní místa
-
-
Massachusetts
-
Boston, Massachusetts, Spojené státy, 02115
- Boston Children's Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- All patients will be admitted to the NICU, and having a post-menstrual age of >28 weeks. Participants will be divided into four groups according to the following criteria:
Group A
- Plan for major surgery anticipated to cause pain and agitation (i.e. esophageal atresia treatment);
- Patients who are anticipated to receive prolonged post-surgical neuromuscular blockade
Group B
- Plan for major surgery anticipated to cause pain and agitation (i.e. bowel surgery);
- Patients who are not anticipated to receive acute post-surgical neuromuscular blockade
Group C Plan for minor surgery anticipated to cause pain and agitation (i.e. hernia repair);
Group D No plan for surgery
Exclusion Criteria:
- Confirmed or suspected clinical seizures
- Metabolic abnormalities or inborn error of metabolism
- Skin abrasions or wounds located at the site of research sensor placement i.e. scalp, which interfere with the application of electrodes
Studijní plán
Jak je studie koncipována?
Detaily designu
- Observační modely: Kohorta
- Časové perspektivy: Budoucí
Počet skupin / kohort
Kohorty a intervence
Skupina / kohortaSkupina / kohorta |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Group A
The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. These subjects will also receive EMG monitoring. Subjects in this group will also have video recordings that may be used for novel analysis such as subdermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group B
The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group C
Plan for minor surgery anticipated to cause pain and agitation (i.e. hernia repair) The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
|
Group D
No plan for surgery The following devices will be used in this Group: Waveguard (TM) EEG cap; Micro Movement Sensor; Pico Movement Sensor; QS Piezostimulator; tactileTM sensory evaluator. Subjects in this group will also have video recordings that may be used for novel analysis such as sub-dermal blood flow or micro-movement. |
The device is an EEG cap - a non-invasive EEG positioning system used to quickly place a large number of surface electrodes in a quick and consistent manner on the head.
The device will measure electrophysiological signals from the scalp at the time points in the study listed in the protocol.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor breathing and movement in children; the device is not used for validation purposes.
This device is not FDA approved.
This device is in clinical use for all age groups and used for research purposes by neurologists, physiologists and anesthesiologists.
In this study, the device is used to monitor respiration rate and gross body movement in children.
The device will not be used for validation purposes.
This device is not FDA approved.
This device is used for research purposes by neurologists and physiologists.
It is a mechanical tactile stimulator for use in functional imaging experiments like MEG, fMRI or EEG.
The stimulation is realized by using several different pin matrices.
In this study, the device is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
This device is not FDA approved.
This device is used for clinical and research purposes by neurologists and physiologists.
It is used to stimulate the children's extremities in order to elicit somatosensory evoked responses.
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Noxious Stimuli Results
Časové okno: Up to 1 year
|
To assess pain-specific brain activity and autonomic responses post surgery in response to an acute noxious procedure in newborn infants admitted to the NICU. This outcome will be correlated with current behavioral and physiological based pain assessment tools as follows: Procedural-specific brain activity in infants with varying conditions with pre or post-operative pain. EEG: amplitude of noxious-event related potential evoked by a time-locked noxious stimulus. Pain-specific electro-dermal activity (EDA), electromyography (EMG) and subdermal skin flow; Pain-evoked behavioral measures including: Body movement; Eye squeeze, brow bulge and nasolabial furrow duration. Pain-evoked physiological measures including: Respiration rate; Heart rate; Blood pressure; Oxygen saturation; Observational pain scores (PIPP); EMG activity. |
Up to 1 year
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Resting State Results
Časové okno: Up to 1 year
|
Characterize resting state activity in post-operative or control subjects as follows: Baseline brain (EEG) activity (power spectra of baseline EEG signal) in post operative or control subjects. Baseline EDA, EMG and subdermal skin flow; Baseline behavioral measures including: Presence of body movement, eye squeeze, brow bulge and nasolabial furrow. Baseline physiological measures including: Respiration rate; Heart rate; Blood pressure; Oxygen saturation; Observational pain scores (PIPP). The relationship with resting brain activity, electrodermal activity, behavior, physiological, and observational pain scores will be evaluated. |
Up to 1 year
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Laura Cornelissen, PhD, Boston Children's Hospital
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- IRB-P00022180
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .