Spirometry Using Electrical Impedance Tomography (EIT)
Realization of Spirometry Measurement Using Electrical Impedance Tomography (EIT)
The main aim of this study is to test spirometry measurements using EIT with a calibration using tidal volume obtained from the simultaneous standard spirometry measurement. Another goal is to compare, based on the calibration, the spirometry parameters obtained from separate measurements using EIT and the standard spirometry using a pneumotachograph.
All spirometry measurements will be conducted in accordance with the latest available standards of the American Thoracic Society (ATS) and European Respiratory Society (ERS) from the year 2005, including their emendation from 2017.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Czech Republic
-
Kladno, Czech Republic, Česko, 272 01
- Department of Biomedical Technology Faculty of Biomedical Engineering Czech Technical University in Prague
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Healthy males and females > 18 years old
- Signed informed consent has been obtained
Exclusion Criteria:
- Pregnancy
- Cardiac pacemakers
- Electrically active implant
- Critical illness
- Intrathoracic metal implants
- Value of body mass index (BMI)>50
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Podpůrná péče
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Žádné (otevřený štítek)
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Žádný zásah: Standard spirometry
Standard spirometry measurement with a pneumotachograph alone.
|
|
|
Experimentální: EIT alone
Spirometric examinations realized using the EIT
|
Spirometric examinations will be realized using the EIT alone.
|
|
Experimentální: Simultaneous standard spirometry and EIT
Simultaneous measurement by spirometer and EIT
|
Spirometric examinations will be realized using the simultaneous measurement by spirometer and EIT
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
FVC
Časové okno: through study completion, an average of 1 year
|
forced vital capacity (L)
|
through study completion, an average of 1 year
|
|
FEV1
Časové okno: through study completion, an average of 1 year
|
forced expiratory volume exhaled in the first second of a forced expiration (L)
|
through study completion, an average of 1 year
|
|
TI
Časové okno: through study completion, an average of 1 year
|
ratio of FEV1/FVC called Tiffeneau index (-)
|
through study completion, an average of 1 year
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Karel Roubík, prof., Czech Technical University in Prague, FBMI
Publikace a užitečné odkazy
Obecné publikace
- Ngo C, Leonhardt S, Zhang T, Luken M, Misgeld B, Vollmer T, Tenbrock K, Lehmann S. Linearity of electrical impedance tomography during maximum effort breathing and forced expiration maneuvers. Physiol Meas. 2017 Jan;38(1):77-86. doi: 10.1088/1361-6579/38/1/77. Epub 2016 Dec 22.
- Vogt B, Lohr S, Zhao Z, Falkenberg C, Ankermann T, Weiler N, Frerichs I. Regional lung function testing in children using electrical impedance tomography. Pediatr Pulmonol. 2018 Mar;53(3):293-301. doi: 10.1002/ppul.23912. Epub 2017 Nov 14.
- Lehmann S, Leonhardt S, Ngo C, Bergmann L, Ayed I, Schrading S, Tenbrock K. Global and regional lung function in cystic fibrosis measured by electrical impedance tomography. Pediatr Pulmonol. 2016 Nov;51(11):1191-1199. doi: 10.1002/ppul.23444. Epub 2016 Apr 29.
- Vogt B, Zhao Z, Zabel P, Weiler N, Frerichs I. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease. Am J Physiol Lung Cell Mol Physiol. 2016 Jul 1;311(1):L8-L19. doi: 10.1152/ajplung.00463.2015. Epub 2016 May 17.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
Další identifikační čísla studie
- EITspiro
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .