Effect of Light Emitting Diode Therapy on Muscle Fatigue (LED)
Effect of Different Pre Application Time Intervals of Light Emitting Diode Therapy on Muscle
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
- To determine the effect of light emitting diode applied 5 minutes before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
- To determine the effect of light emitting diode applied 1 hour before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
- To determine the effect of light emitting diode applied 5 hours before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
- To determine the difference between light emitting diode applied 5 minutes,1 hour or 5 hours before exercise on pain, rate of perceived exertion and maximum voluntary contraction.
Typ studie
Typ studie
Zápis (Očekávaný)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
Cairo, Egypt
- Faculty of Physical Therapy
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Healthy non athletics subjects.
- Age ranges from 20-40 years.
- Body mass index is less than 25 kg/m 2
Exclusion Criteria:
- Neurological deficit and recent injury to either upper extremity
- non diagnosed pain .
- Contraindications to LED irradiation (such as light hypersensitivity, fluctuating blood pressure, insufficient blood circulation, fever and inflammation of the skin)
- Conditions in which physical exertion is contraindicated (such as cardiovascular deficits, hypertension and respiratory problems)
- Restriction in shoulder or elbow range of motion;
- Neoplasm,
- Rheumatoid,
- Strength training in the past 6 months;
- Previous surgery in the spine or upper extremity;
- Complaints of pain in the shoulder, elbow,wrist, and trunk musculature system;
- Use of dietary supplements; and not in any other exercise program for at least the past 3 months.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Prevence
- Přidělení: Randomizované
- Intervenční model: Crossover Assignment
- Maskování: Singl
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Experimentální: 5 minutes before 1
Light emitting diode applied 5 minutes before fatiguing task
|
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
|
|
Komparátor placeba: 5 minutes before 2
Light emitting diode applied 5 minutes before fatiguing task
|
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
|
|
Experimentální: 1 hour before 1
Light emitting diode applied 1 hour before fatiguing task
|
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
|
|
Komparátor placeba: 1 hour before 2
Light emitting diode applied 1 hour before fatiguing task
|
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
|
|
Experimentální: 5 hours before 1
Light emitting diode applied 5 hours before fatiguing task
|
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
|
|
Komparátor placeba: 5 hours before 2
Light emitting diode applied 5 hours before fatiguing task
|
Light emitting diode at a wavelength of 890 nm is produced by an array of 60 gallium aluminum arsenide light-emitting diodes located on flexible pads and the near infrared photo energy is delivered in a noninvasive, drug-free manner
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Isometric peak torque of elbow flexors
Časové okno: change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
|
metric unit is Newton
|
change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
|
|
Isometric peak torque of elbow flexors
Časové okno: change from before light emitting diode application at1 minute
|
metric unit is Newton
|
change from before light emitting diode application at1 minute
|
|
Isokinetic peak torque of elbow flexors
Časové okno: change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
|
Metric unit is Newton and at angular velocity 60
|
change from before light emitting diode application at 5 minutes, 1 hour and 5 hours
|
|
Isokinetic peak torque of elbow flexors
Časové okno: change from before light emitting diode application at 1 minute after light emitting diode application
|
Metric unit is Newton and at angular velocity 60
|
change from before light emitting diode application at 1 minute after light emitting diode application
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Očekávaný)
Primární dokončení
Dokončení studie (Očekávaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- P.T.REC/012/002480
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .