Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Deformable Tissue Modelling and Augmented Reality Based Guidance for Head and Neck Tumor Re-Resection Task (SPeAR)

5. srpna 2026 aktualizováno: Michael Topf, Vanderbilt University Medical Center

Head and neck cancers have one of the highest recurrence rates among solid malignancies, and recurrence is strongly correlated with overall survival. Reducing recurrence rates depends, in part, on the surgeon's ability to accurately re-resect areas of positive or close margins during surgery. Currently, margin status is communicated primarily through verbal descriptions between the surgeon and pathologist, which can be imprecise. This challenge is further compounded by the deformable nature of soft tissues, as once the specimen is resected, the shape and size of the specimen change, making it difficult to accurately map the specimen's margins back onto the surgical site.

Emerging technologies -such as augmented reality (AR), 3D scanning, and advanced soft tissue modeling- offer promising solutions for improving surgical navigation and precision. Building on these advances, an AR-based surgical navigation system was developed specifically for head and neck tumor resections. The system uses a 3D scanner to generate virtual models of both the resected specimen and the patient's surgical site, as demonstrated in prior work. A soft tissue modeling algorithm is then applied to account for specimen shrinkage and deformation, enabling accurate tracking of positive tumor margins. This guidance information is visualized through an AR headset, which overlays the margin data directly onto the patient's surgical site, providing surgeons with real-time visual guidance during re-resection.

In this study, the goal is to evaluate the benefits and usability of this novel navigation software, compared to the standard of care. By assessing surgeon performance and user experience in cadaveric tasks with and without the AR system to identify strengths, limitations, and opportunities for refinement of the system, ultimately advancing surgical precision and improving patient outcomes by reducing recurrence rates.

Přehled studie

Postavení

Nábor

Podmínky

Intervence / Léčba

Detailní popis

Augmented reality (AR) technology, combined with computer vision algorithms, offers significant potential to enhance surgical visualization by generating GPS-like spatial maps over the patient's anatomy. This study aims to evaluate the usability and impact of our AR surgical guidance system, delivered through Microsoft HoloLens 2 (or equivalent AR/VR goggles such as Magic Leap or Apple Vision Pro), among surgeons while they complete various surgical tasks on cadaveric specimens. Specifically, an assessment of how the AR system influences surgeon performance and user experience during tasks such as suturing and specimen relocation, performed both with and without AR assistance.

Task accuracy (e.g., resection precision) will be measured and survey responses will be collected to assess the system's usability, ease of use, and comfort. Building on prior work where the investigators validated the feasibility and accuracy of AR-guided surgical holograms, this study focuses on advancing the evaluation of the system's usability and impact on performance. The goal is to generate insights into the application of AR guidance in head and neck tumor resection, ultimately contributing to improved intraoperative surgical precision and patient outcomes.

Typ studie

Intervenční

Zápis (Odhadovaný)

30

Fáze

  • Raná fáze 1

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

  • Jméno: Jie Ying Wu Assistant Professor of Computer Science, PhD
  • Telefonní číslo: 615-343-4996
  • E-mail: JieYing.Wu@vanderbilt.edu

Studijní místa

    • Tennessee
      • Nashville, Tennessee, Spojené státy, 37232
        • Nábor
        • Vanderbilt University Medical Center
        • Kontakt:
          • Jie Ying Wu Assistant Professor of Computer Science, PhD
          • Telefonní číslo: 615-343-4996
          • E-mail: JieYing.Wu@vanderbilt.edu

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dítě
  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ne

Studijní populace

Surgeon-physician, surgical fellow, or post-graduate year 1, 2, 3, 4 and 5 (PGY2-5) resident physicians

Popis

Inclusion Criteria:

  1. Post-graduate year 1, 2, 3, 4 and 5 (PGY2-5) resident physicians. (no age limit)
  2. Surgical fellows.
  3. Attending physicians.
  4. Prior cadaver lab or surgical experience.
  5. Any surgeon, regardless of training and experience, who has been involved in the surgeon-pathologist interaction during surgical resection for frozen section and margin clearance assessment.

Exclusion Criteria:

1. Non-physician surgery providers.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Proveditelnost zařízení
  • Přidělení: N/A
  • Intervenční model: Přiřazení jedné skupiny
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Jiný: Augmented Reality (AR)

Participants will be asked to localize simulated margins on tissue resection beds on a fresh-frozen cadaver head. Specimens of skin, buccal, or tongue tissue will be resected by the research team beforehand.

Participants will be asked to place pins or stitches where the indicated targets are located. These positions will be recorded by the research team.

Participants will first receive oral guidance only, corresponding to common descriptions between pathologists and surgeons.

Participants will then reproduce the same task with AR guidance. In this case, the target will be displayed in the see-through AR headset. The target will be overlaid on the resection bed site and follow your head's movements.

Task accuracy will be evaluated by measuring distances between the points identified with and without AR guidance, and the pathologist-intended target locations.

Participants will then complete post-tasks surveys and interviews.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Performance Task accuracy (e.g., resection precision)
Časové okno: within 90 minutes of AR-guided use
Surgeon performance of target re-localization compared with and without the AR-headset.
within 90 minutes of AR-guided use
User Experience
Časové okno: immediately after the AR-guided task.
Assess AR usability, ease of use, and comfort, through surgeon feedback surveys
immediately after the AR-guided task.
Accuracy of overlay alignment
Časové okno: within 90 minutes of completing the AR-guided task.
This will validate the accuracy of overlay alignment through landmark-based (tumor margin relocation) error metrics, which support precision of re-resection tasks.
within 90 minutes of completing the AR-guided task.

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Sponzor

Spolupracovníci

Vyšetřovatelé

  • Vrchní vyšetřovatel: Michael Topf, MD, Vanderbilt University Medical Center

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

18. února 2026

Primární dokončení (Odhadovaný)

1. června 2029

Dokončení studie (Odhadovaný)

1. června 2029

Termíny zápisu do studia

První předloženo

30. června 2026

První předloženo, které splnilo kritéria kontroly kvality

30. června 2026

První zveřejněno (Aktuální)

7. července 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

10. srpna 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

5. srpna 2026

Naposledy ověřeno

1. června 2026

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • 251090

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NEROZHODNÝ

Popis plánu IPD

NIH requires through Data Management and Sharing Plans (DMSP) that all data collected during the research project be archived indefinitely and shared with the community after the project termination. De-identified data will then be transferred to Open Science Framework (OSF).

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .