Prevention and Reduction of Falls: Testing and Evaluating Cutting Edge Haptic Technology (PROTECT)
Prevention and Reduction of Falls: Testing and Evaluating Cutting Edge Haptic Technology (PROTECT)
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
The PROTECT Study is designed to classify participants into fall-risk categories and evaluate whether use of the LIBERTY Patch, a drug-free, non-invasive, investigational device employing Haptic Vibrotactile Trigger Technology, is associated with a change in fall-risk category or balance/mobility confidence relative to a sham (inactive) patch control.
After informed consent, participants complete a Baseline Survey (including the Falls Efficacy Scale, a 10-item instrument adapted from Tinetti et al., 1990, assessing confidence in performing daily activities without falling) and undergo a brief (2-3 minute) walking and mobility assessment using the FallSkip wearable device, worn at the waist, involving sitting, standing, walking several feet, and returning to a seated position. Participants are then given a study patch - either the active LIBERTY Patch or a visually identical sham patch - to wear daily. After 7 days, participants repeat the FallSkip mobility assessment and complete a Follow-Up Survey, which re-administers the Falls Efficacy Scale and adds items on patch satisfaction, ease of use, convenience, and any side effects experienced (hot/cold sensation, massage/tingling sensation, pressure sensation, or none). Neither the participant nor the investigator is informed of patch assignment during the study period, though the investigator can unblind in case of emergency. After the 7-day period, participants may optionally continue in the study using the alternate patch.
Typ studie
Typ studie
Zápis (Odhadovaný)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Texas
-
Mansfield, Texas, Spojené státy, 76063
- Anna Toker, MD
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Popis
Inclusion Criteria:
- Ages 55 to 85, inclusive
- Able to provide written informed consent
- Able to walk independently or with assistive devices
- Lucid, with adequate cognitive ability to consent
Exclusion Criteria:
- History of severe neurological disorders (e.g., advanced Parkinson's, severe stroke history)
- Known allergies to adhesives
- Currently hospitalized
- Use of drugs of abuse (illicit or prescription)
- Severe visual/auditory impairments affecting gait or balance
- Terminal illness or life expectancy less than 6 months
- Severe dementia or cognitive impairment preventing consent
- Ongoing physical therapy specifically targeting balance/gait
- Post-stroke
- Pregnant
- Existing or planned implantation of a pacemaker or other electrical device
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Prevence
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Dvojnásobek
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Aktivní komparátor: Active LIBERTY Patch (Vibrotactile/Haptic)
Participants apply the active LIBERTY Patch (Haptic Vibrotactile Trigger Technology) daily for 7 days, with fall-risk/mobility assessment (FallSkip device) and Falls Efficacy Scale survey completed at baseline and Day 7.
|
A drug-free, non-invasive, investigational topical patch designed to assist with balance and mobility, worn daily for 7 days.
Ostatní jména:
|
|
Falešný srovnávač: Control (Sham Patch)
Participants apply a visually identical sham patch without active technology daily for 7 days, with the same baseline and Day 7 assessments as the Active arm.
|
A visually identical patch without active technology, worn daily for 7 days under the same conditions as the active patch.
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Change in fall-risk/mobility assessment (FallSkip device)
Časové okno: Baseline and Day 7
|
A 2-3 minute mobility assessment (sit-to-stand, walking, and return to seated position) using the FallSkip wearable device, comparing Active vs.
Control groups.
|
Baseline and Day 7
|
|
Change in Falls Efficacy Scale score
Časové okno: Baseline and Day 7
|
A 10-item, self-reported scale (adapted from Tinetti et al., 1990) measuring confidence in performing daily activities (bathing, dressing, walking, transferring, etc.) without falling, scored 1 (very confident) to 10 (not confident at all) per item.
|
Baseline and Day 7
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Incidence of patch-associated sensations/side effects
Časové okno: Throughout the 7-day study period, assessed at Day 7
|
Self-reported occurrence of hot/cold sensation, massage/tingling sensation, pressure sensation, or none, associated with patch use.
|
Throughout the 7-day study period, assessed at Day 7
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Spolupracovníci
Spolupracovníci
Publikace a užitečné odkazy
Obecné publikace
- Tinetti ME, Richman D, Powell L. Falls efficacy as a measure of fear of falling. J Gerontol. 1990 Nov;45(6):P239-43. doi: 10.1093/geronj/45.6.p239.
- Fason J, Hurwitz P, Gudin J. Reducing Pain and Improving Mobility Using Haptic Patch Technology: Results of the RESTORE Study. Pain Ther. 2025 Dec;14(6):1797-1807. doi: 10.1007/s40122-025-00780-0. Epub 2025 Oct 8.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Odhadovaný)
Primární dokončení
Dokončení studie (Odhadovaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- PROTECT-001
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .