Multimodal Biomarkers in Individual With Cognitive Impairment and Dementia
Multimodal Biomarkers in Individual With Cognitive Impairment and Dementia: A Case Control Study
Memory problems can range from normal aging to mild cognitive impairment (MCI) to dementia. This study looks at three ways of measuring what is happening in the brain at each of these stages: a blood test (GFAP), a brain MRI scan, and a brain wave test (EEG). The goal is to see whether combining these three tests can help doctors tell the difference between normal aging, MCI, and dementia more accurately, and whether this approach works well in an Egyptian population, including all common causes of dementia (not only Alzheimer's disease).
Adults aged 50 to 85 will be placed into one of three groups: those with normal memory, those with mild memory problems (MCI), and those with dementia. Everyone will have a memory and thinking assessment, a blood draw, a brain MRI, and a brain wave (EEG) recording. No new medication or treatment is given as part of this study; it involves only assessment and testing. The information gathered may help doctors diagnose memory problems earlier and more accurately in the future.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Detailní popis
This is a cross-sectional, observational, case-control study designed to characterize and compare plasma glial fibrillary acidic protein (GFAP), quantitative electroencephalography (EEG), and MRI-based brain volumetry across three groups: healthy controls, participants with mild cognitive impairment (MCI), and participants with dementia of any etiology (Alzheimer's, vascular, Lewy body, frontotemporal, or mixed).
Plasma GFAP, an astrocytic activation marker, will be quantified from EDTA-collected blood via automated chemiluminescent immunoassay (Lumipulse or Alinity platform where available) or conventional ELISA. Structural brain volumetry (hippocampal, medial temporal, and whole-brain/ventricular volumes) will be derived from 3-Tesla MRI using a 3D T1-weighted MPRAGE sequence with automated segmentation. Resting-state EEG will be recorded using a 19-channel 10-20 electrode montage for quantitative spectral power analysis across standard frequency bands.
All participants will undergo a standardized clinical and psychometric assessment, including the Montreal Cognitive Assessment (MoCA), Clinical Dementia Rating (CDR), and functional assessment via the Katz Index and Lawton-Brody Instrumental Activities of Daily Living scale, to confirm group classification prior to biomarker collection.
The study addresses a gap in the literature: although plasma GFAP, MRI volumetry, and EEG have each been separately validated as markers of neurodegeneration, few studies have jointly acquired all three modalities within a single cohort spanning the full continuum from normal cognition through dementia, and fewer still have done so in an Egyptian or broader Middle East/North Africa population across all dementia etiologies rather than Alzheimer's disease alone. Findings from this study are intended to inform the development of a combined biomarker panel for earlier and more accurate differentiation between normal cognitive aging, MCI, and dementia.
Typ studie
Typ studie
Zápis (Odhadovaný)
Zápis
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Dementia diagnosed according to DSM -5\ with a total Mini-Mental State Examination score < 24 (or < 22 according to educational state), together with a Modified Mini-Mental State Examination (3MS) score < 79 to confirm cognitive impairment.
- Mild cognitive impairment diagnosed according to established diagnostic criteria according to DSM -5.
- Men or women of at least 50 years of age.
- Reliable in individual data and willing to make themselves available for the duration of the study.
- Clear written informed consent obtained from a first-degree relative for each patient participant, and from the control participant himself/herself.
Exclusion Criteria:
age below 50 years .
- other neurological disorders or psychiatric disorders; previous history of stroke; metabolic disturbance; other major medical illnesses; epilepsy; inflammatory, autoimmune, or infectious disease; metallic objects in the body; craniotomy in the past.
- Presence of clinically significant medical or psychiatric condition that may increase the risk associated with the study
- MRI contraindication (pacemaker, metallic implants, severe claustrophobia).
Studijní plán
Jak je studie koncipována?
Detaily designu
Počet skupin / kohort
Kohorty a intervence
Skupina / kohortaSkupina / kohorta |
|---|
|
Dementia
according toDSM -5 , with a total Mini-Mental State Examination score < 24 (or < 22 according to educational state), together with a Modified Mini-Mental State Examination (3MS) score < 79 to confirm cognitive impairment
|
|
Mild Cognitive impairment
impairment diagnosed according to established diagnostic criteria
|
|
control
healthy group matched age, sex
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Plasma Concentration of Glial Fibrillary Acidic Protein (GFAP)main outcome
Časové okno: Baseline (single time point)
|
Measured in picograms per milliliter (pg/mL) via automated chemiluminescent immunoassay (Lumipulse or Alinity platform) or ELISA, from venous blood collected in EDTA tubes
|
Baseline (single time point)
|
|
Hippocampal Volume on MRI, Whole-Brain Volume on MRI,Ventricular Volume on MRI
Časové okno: Baseline (single time point)
|
Measured in cubic millimeters (mm³), normalized to total intracranial volume, derived from 3-Tesla 3D T1-weighted MPRAGE MRI using automated segmentation software (FreeSurfer)
|
Baseline (single time point)
|
|
EEG Band Power Alpha , beta , delta , theta
Časové okno: Baseline (single time point)
|
Absolute spectral power (µV²) in the different frequency band , derived from resting-state EEG recorded with a 19-channel 10-20 electrode montage
|
Baseline (single time point)
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Correlation Between Plasma GFAP and MRI Volumetric Measures Across Dementia Etiological Subtypes
Časové okno: Baseline (single time point)
|
Pearson/Spearman correlation coefficient between plasma GFAP concentration (pg/mL) and MRI-derived regional brain volumes (mm³), calculated separately within Alzheimer's, vascular, Lewy body, frontotemporal, and mixed dementia subgroups
|
Baseline (single time point)
|
|
Correlation Between Plasma GFAP and EEG Spectral Power Measures Across Dementia Etiological Subtypes
Časové okno: Baseline (single time point)
|
Pearson/Spearman correlation coefficient between plasma GFAP concentration (pg/mL) and EEG band power (µV²), calculated separately within Alzheimer's, vascular, Lewy body, frontotemporal, and mixed dementia subgroups
|
Baseline (single time point)
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Odhadovaný)
Začátek studia
Primární dokončení (Odhadovaný)
Primární dokončení
Dokončení studie (Odhadovaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- Biomarkers of cognition
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .