Gemini Flash 3.6 Versus Human Observers for FIGO-Based Interpretation of Intrapartum Cardiotocography
Gemini Flash 3.6 Versus Human Observers for FIGO-Based Interpretation of Intrapartum Cardiotocography: A Diagnostic Accuracy Study
Cardiotocography (CTG) is the standard method for monitoring fetal heart rate and uterine contractions during labor to detect signs of fetal hypoxia. However, human CTG interpretation is often subjective and subject to high interobserver variability, even among experienced clinicians. Multimodal artificial intelligence (AI) models have emerged as potential diagnostic aids capable of evaluating CTG tracings. This prospective diagnostic accuracy study aims to evaluate the diagnostic performance of Gemini Flash 3.6 in interpreting intrapartum CTG recordings according to the 2015 International Federation of Gynecology and Obstetrics (FIGO) guidelines, and to compare its accuracy directly against independent human expert obstetricians.
Participants include pregnant women admitted in active labor at term with a singleton cephalic pregnancy undergoing continuous CTG monitoring. De-identified digital images of the final 60 minutes of CTG tracing prior to delivery will be independently evaluated by Gemini Flash 3.6 and three expert obstetricians. Each evaluator will classify the tracings into one of three FIGO categories: Normal, Suspicious, or Pathological. All evaluators will be blinded to clinical details, delivery outcomes, and other observers' interpretations.
The primary objective is to assess the diagnostic sensitivity of Gemini Flash 3.6 in identifying neonates with a 5-minute Apgar score less than 7. Secondary objectives include comparing the diagnostic performance of the AI model with that of individual expert obstetricians, measuring interobserver agreement among all raters, and assessing associations with 1-minute Apgar scores and umbilical artery blood gas parameters. The AI model will be used solely as an investigational research tool, and its evaluations will not be available to the clinical team or used to guide patient care.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Typ studie
Typ studie
Zápis (Odhadovaný)
Zápis
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Singleton pregnancy
- Gestational age 37+0 weeks or greater
- Cephalic fetal presentation
- Admission to the labor ward in active labor
- Continuous intrapartum cardiotocography (CTG) monitoring
- Availability of an interpretable CTG tracing immediately preceding delivery
- Availability of documented 1-minute and 5-minute Apgar scores
- Written informed consent obtained prior to enrollment
Exclusion Criteria:
- Multiple pregnancy
- Major fetal congenital anomalies
- Antepartum stillbirth
- Elective cesarean delivery performed before the onset of labor without an adequate intrapartum CTG tracing
- CTG tracing with inadequate technical quality, including signal loss of 15% or greater
- Missing 5-minute Apgar score
- Technical problems preventing standardized CTG image preparation or interpretation
Studijní plán
Jak je studie koncipována?
Detaily designu
Počet skupin / kohort
Kohorty a intervence
Skupina / kohortaSkupina / kohorta |
|---|
|
Intrapartum CTG Monitoring Cohort
Women with singleton term pregnancies (gestational age ≥ 37 + 0 weeks) in cephalic presentation admitted to the labor ward in active labor who undergo routine continuous intrapartum cardiotocography (CTG) monitoring immediately preceding delivery.
De-identified digital CTG tracings from this cohort are independently evaluated by Gemini Flash 3.6 and three expert obstetricians according to the 2015 FIGO consensus guidelines, and validated against neonatal outcomes including 1-minute and 5-minute Apgar scores as well as umbilical artery blood-gas analysis where available.
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Sensitivity of Gemini Flash 3.6 for Identifying Neonates With a 5-Minute Apgar Score Less Than 7
Časové okno: 5 minutes after birth
|
Sensitivity is defined as the percentage of neonates with a confirmed 5-minute Apgar score less than 7 who are correctly identified as having a "Pathological" CTG tracing by Gemini Flash 3.6.
Intrapartum CTG tracings from the final 60 minutes of labor immediately preceding delivery are interpreted according to the 2015 FIGO guidelines.
For binary diagnostic performance analysis, a "Pathological" CTG represents a positive test result, while "Normal" and "Suspicious" CTGs represent negative test results.
Sensitivity is calculated as [True Positives / (True Positives + False Negatives)] * 100 and reported with a 95% confidence interval.
|
5 minutes after birth
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Odhadovaný)
Začátek studia
Primární dokončení (Odhadovaný)
Primární dokončení
Dokončení studie (Odhadovaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- Gemini Flash vs Human FIGO CTG
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .