Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Investigating the Relationship Between Measures of the Hearing Nerve and Speech Perception Outcomes in Adult Nexa Cochlear Implant Recipients (NODE-SDN)

16. listopadu 2026 aktualizováno: Cochlear

Prospective, Interventional, Multicentre Feasibility Investigation Evaluating Objective Measures and Clinical Outcomes in Adult Nexa® Cochlear Implant Recipients

This study aims to learn more about the information that can be obtained directly from measurements through a Nexa cochlear implant during and after surgery. Researchers will investigate whether these measurements can help understand how the implant is interacting with the inner ear and hearing nerve, where the electrodes are positioned inside the cochlea, and potentially how the implant should be programmed and how well a person detects sounds.

The study will also evaluate how well two methods agree in determining the position of the electrode contacts relative to the anatomy of the inner ear and the hearing nerve. One method uses measurements after surgery made through the implant itself. The other uses medical Computed Tomography(CT) imaging made after the surgery. The information collected will also contribute to a clinical research database that may be used to support future research and development. Participants will be told about this potential future use when they provide consent.

Přehled studie

Postavení

Zatím nenabíráme

Podmínky

Intervence / Léčba

Typ studie

Intervenční

Zápis (Odhadovaný)

200

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní kontakt

Studijní záloha kontaktů

Studijní místa

    • Victoria
      • East Melbourne, Victoria, Austrálie, 3002
        • The University of Melbourne, Royal Victorian Eye and Ear Hospital
        • Vrchní vyšetřovatel:
          • Stephen O'Leary, MBBS, PhD, FRACS
    • Antwerp
      • Wilrijk, Antwerp, Belgie, 2610
        • Sint Augustinus ENT European Institute for ORL-HNS
        • Vrchní vyšetřovatel:
          • Andrzej Zarowski, MD
    • Lower Saxony
      • Hanover, Lower Saxony, Německo, 30625
        • Medizinische Hochschule Hannover
        • Vrchní vyšetřovatel:
          • Andreas Büchner, PhD
    • Missouri
      • St Louis, Missouri, Spojené státy, 63141
        • Washington University School of Medicine Ear, Nose & Throat Centre
        • Vrchní vyšetřovatel:
          • Amit Walia, MD
    • Utah
      • Salt Lake City, Utah, Spojené státy, 84132
        • University of Utah Hospitals and Clinics
        • Vrchní vyšetřovatel:
          • Craig Buchman, MD

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let a starší (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

  1. Aged 18 years or older (no upper age limit).
  2. Candidate for CI1032 cochlear implantation as per the local sensorineural hearing loss criteria.
  3. Sufficient proficiency in the language used to conduct the study procedures, as determined by the investigator.
  4. Availability of pre-op CT scan of the cochlear region meeting quality requirements as determined by the sponsor.
  5. Willing and able to provide written informed consent and to comply with all requirements of the protocol.

Exclusion Criteria:

  1. Previous cochlear implantation in the same ear.
  2. Cochlear implant in the contralateral ear.
  3. Have an unaided air conduction pure tone average (average of unaided thresholds at 0.5, 1, 2 and 4 kHz) ≤40 dB HL in the contralateral ear measured within the last 12 months
  4. Severe or greater sensorineural hearing loss prior to 2 years of age, as documented in medical history.
  5. Deafness due to lesions of the auditory nerve or central auditory pathway.
  6. Cochlear ossification or anatomical anomaly precluding full electrode array insertion.
  7. Diagnosis of auditory neuropathy.
  8. Additional conditions preventing or restricting participation in the audiological evaluations, as determined by the investigator.
  9. Pregnant or breastfeeding women.
  10. Unrealistic expectations on the part of the subject regarding the potential benefits, risks, and limitations of the surgical procedure and device.
  11. Unable or unwilling to comply with the requirements of the clinical investigation as determined by the Investigator.
  12. Investigator site personnel directly affiliated with this study and/or their immediate families; immediate family is defined as a spouse, parent, child, or sibling.
  13. Cochlear employees or employees of Contract Research Organisations or contractors engaged by Cochlear for the purposes of this investigation.
  14. Current participation, or participation in another interventional clinical study/trial in the past 30 days, involving an investigational drug or device (unless determined by the Sponsor to not impact this investigation).

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Diagnostický
  • Přidělení: N/A
  • Intervenční model: Přiřazení jedné skupiny
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: Cochlear implant recipients

Adult participants receiving a commercial Cochlear Nucleus Nexa cochlear implant, who undergo additional investigational objective measure procedures performed intra- and post-operatively.

Participants will be tested with intra- and post-operative objective measures, including Transimpedance Matrix (TIM) and Neural Response telemetry (NRT) recordings, using monopolar and focused multipolar stimulation.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Correlation Between CT-Derived Electrode-to-Modiolus Distance and MAP T-Levels
Časové okno: Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative computed tomography (CT) imaging and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and MAP T-levels.

Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation
Correlation Between CT-Derived Electrode-to-Modiolus Distance and MAP C-Levels
Časové okno: Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative CT imaging and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and MAP C-levels.

Postoperative CT assessment and cochlear implant programming assessment at 6 months post-activation
Correlation Between CT-Derived Electrode-to-Modiolus Distance and Aided Pure-Tone Thresholds
Časové okno: Postoperative CT assessment and aided hearing assessment at 6 months post-activation.

The correlation between electrode-to-modiolus distance (in millimeters, mm) derived from postoperative CT imaging and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between electrode position and aided hearing thresholds.

Postoperative CT assessment and aided hearing assessment at 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and MAP T-Levels
Časové okno: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and MAP T-levels.

At 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and MAP C-Levels
Časové okno: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and MAP C-levels.

At 6 months post-activation.
Correlation Between Monopolar T-NRT Thresholds and Aided Pure-Tone Thresholds
Časové okno: At 6 months post-activation.

The correlation between monopolar telemetry neural response threshold (T-NRT) measurements (in current level, CL) and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between monopolar T-NRT thresholds and aided hearing thresholds.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and MAP T-Levels
Časové okno: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and cochlear implant MAP threshold (T) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and MAP T-levels.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and MAP C-Levels
Časové okno: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and cochlear implant MAP maximum comfortable (C) levels (in current level, CL) will be assessed. The correlation coefficient with 95% confidence intervals. will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and MAP C-levels.

At 6 months post-activation.
Correlation Between Focused T-NRT Thresholds and Aided Pure-Tone Thresholds
Časové okno: At 6 months post-activation.

The correlation between focused telemetry neural response threshold (T-NRT) measurements (in current level, CL) and aided pure-tone thresholds (in dBHL) will be assessed. The correlation coefficient with 95% confidence intervals will be reported to characterize the strength and direction of the association between focused T-NRT thresholds and aided hearing thresholds.

At 6 months post-activation.

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Mean Absolute Error Between TIM-Derived and CT-Derived Electrode-to-Modiolus Distance
Časové okno: At 6 months post-activation

Postoperative electrode-to-modiolus distance for individual electrode contacts will be determined using postoperative computed tomography (CT) imaging and using Transimpedance Matrix (TIM) measurements analysed with an algorithm. The mean absolute error between paired TIM-derived and CT-derived electrode-to-modiolus distance measurements will be reported in millimetres (mm).

At 6 months post-activation

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Sponzor

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Odhadovaný)

1. ledna 2027

Primární dokončení (Odhadovaný)

1. srpna 2028

Dokončení studie (Odhadovaný)

1. srpna 2028

Termíny zápisu do studia

První předloženo

9. listopadu 2026

První předloženo, které splnilo kritéria kontroly kvality

16. listopadu 2026

První zveřejněno (Aktuální)

23. listopadu 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

23. listopadu 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

16. listopadu 2026

Naposledy ověřeno

1. listopadu 2026

Více informací

Termíny související s touto studií

Klíčová slova

Další identifikační čísla studie

  • AI02841

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ano

produkt vyrobený a vyvážený z USA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .