Assessment of Internal Fit and Marginal Adaptation of Inlay Zirconia Fixed Bridge Using Intraoral Versus Extraoral Scanner
Assessment of Internal Fit and Marginal Adaptation of Inlay Zirconia Fixed Bridge Using Intra Oral Scanner Versus Extra Oral Scanner
This in vitro study aims to assess and compare the marginal adaptation and internal fit of inlay zirconia fixed bridges fabricated using intraoral scanning and extraoral scanning. The study will be performed on a Nissen typodont model. Prepared teeth replacing a missing lower first molar will be scanned using intraoral and extraoral scanning techniques. The resulting zirconia fixed bridges will be evaluated for marginal adaptation as the primary outcome and internal fit as the secondary outcome using a stereomicroscope.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
Conventional fixed dental prostheses may require extensive reduction of healthy tooth structure. Inlay-retained fixed dental prostheses provide a more conservative approach by minimizing unnecessary removal of sound tooth structure. Digital scanning may simplify the workflow and reduce some of the limitations associated with conventional impression techniques.
This in vitro study will compare intraoral scanning (IOS) with extraoral scanning (EOS) for the fabrication of an inlay zirconia fixed bridge replacing a missing lower first molar. The study will be conducted on a Nissen typodont model. The prepared teeth will follow the guidelines for ceramic inlay preparation. Prepared samples fulfilling the eligibility criteria will be allocated into two groups in a 1:1 ratio using a computerized sequence generator.
The primary outcome will be marginal adaptation and the secondary outcome will be internal fit. Both outcomes will be measured using a stereomicroscope in micrometers (µm). The collected numerical data will be assessed for normality using the Kolmogorov-Smirnov and Shapiro-Wilk tests. The Mann-Whitney U test will be used to compare the two impression groups, while Friedman's test will be used to compare predetermined measurement points within each group. Dunn's test will be used for pairwise comparisons when Friedman's test is significant. The significance level will be set at P ≤ 0.05.
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Giza Governorate
-
El-Sheikh Zayed City, Giza Governorate, Egypt, 12451
- Faculty of Dentistry, October University for Modern Sciences and Arts (MSA)
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dítě
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria
- missing lower left 6
- present lower left 5
- present lower left 7
Exclusion Criteria:
- present lower left 6
- missing lower left 5
- missing lower left 7
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Základní věda
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Žádné (otevřený štítek)
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Experimentální: Intraoral Scanner (IOS)
Prepared typodont teeth for an inlay zirconia fixed bridge will be scanned using an intraoral scanner (IOS). The digital scan will be used for fabrication of the inlay zirconia fixed bridge, which will subsequently be evaluated for marginal adaptation and internal fit using a stereomicroscope. |
Intraoral scanning of prepared typodont teeth for fabrication of an inlay zirconia fixed bridge. The digital scan obtained using the intraoral scanner will be used for the CAD/CAM fabrication of the restoration, which will then be evaluated for marginal adaptation and internal fit. |
|
Aktivní komparátor: * Extraoral Scanner (EOS)
Prepared typodont teeth for an inlay zirconia fixed bridge will be scanned using an extraoral scanner (EOS). The digital scan will be used for fabrication of the inlay zirconia fixed bridge, which will subsequently be evaluated for marginal adaptation and internal fit using a stereomicroscope. |
Extraoral scanning of prepared typodont teeth for fabrication of an inlay zirconia fixed bridge. The digital scan obtained using the extraoral scanner will be used for the CAD/CAM fabrication of the restoration, which will then be evaluated for marginal adaptation and internal fit. |
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Marginal adaptation of the inlay zirconia fixed bridge
Časové okno: one day after trial insertion of the inlay zirconia fixed bridge
|
Marginal adaptation will be evaluated by measuring the marginal gap at predetermined points using a stereomicroscope. Measurements will be recorded in micrometers (µm). |
one day after trial insertion of the inlay zirconia fixed bridge
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Internal fit of the inlay zirconia fixed bridg
Časové okno: one day after trial insertion of the inlay zirconia fixed bridge
|
Internal fit will be evaluated at predetermined points using a stereomicroscope. Measurements will be recorded in micrometers (µm). |
one day after trial insertion of the inlay zirconia fixed bridge
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
Další identifikační čísla studie
- 18393
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .