Multicenter Clinical Validation of OSIS for Automated Ovarian Follicle Monitoring (MULTI-OSIS)
Multicenter Clinical Validation of OSIS: A 3D Ultrasound-Based AI Tool for Automated Ovarian Follicle Monitoring in Diverse Clinical Settings
Monitoring ovarian follicles is an important part of fertility treatments, as it helps healthcare professionals assess how the ovaries respond to stimulation. Traditionally, follicles are measured manually using two-dimensional (2D) ultrasound, a process that can be time-consuming and may vary between operators.
This study aims to evaluate the accuracy of OSIS (Online System for Image Segmentation), an artificial intelligence (AI)-based software that automatically identifies and measures ovarian follicles using three-dimensional (3D) ultrasound images.
Women undergoing controlled ovarian stimulation for in vitro fertilization (IVF), egg donation, or fertility preservation will participate in the study at fertility clinics in the United States and Europe. During their ovarian stimulation monitoring visits, conventional manual 2D ultrasound measurements will be compared with automated measurements obtained using OSIS.
The study will also assess the consistency of measurements across different healthcare professionals, clinical settings, and ultrasound equipment, as well as the time required for each measurement method.
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
This prospective, multicenter, observational, comparative clinical study aims to validate the accuracy, reproducibility, and generalizability of OSIS (Online System for Image Segmentation), an artificial intelligence (AI)-based medical device software developed by Fertoolity S.L. to automatically identify, segment, and measure ovarian follicles from three-dimensional (3D) transvaginal ultrasound images.
The study will be conducted across multiple fertility clinics in the United States and Europe, involving women undergoing controlled ovarian stimulation (COS) for in vitro fertilization (IVF), oocyte donation, or fertility preservation.
During routine ovarian stimulation monitoring visits, conventional two-dimensional (2D) ultrasound measurements will be performed manually by healthcare professionals, followed by the acquisition of 3D ovarian ultrasound volumes. These 3D images will be uploaded to the cloud-based OSIS platform for automated follicle segmentation and measurement.
The study will include repeated ultrasound measurements to assess intra-observer variability (consistency of measurements performed by the same operator) and, where applicable, inter-observer variability (consistency between different operators). Depending on the participating center and applicable local requirements, measurements may be performed by physicians, nurses, or ultrasound technicians/sonographers. All collected datasets will be reviewed and validated by the attending physician.
The primary objective is to evaluate the agreement between automated OSIS measurements and conventional manual 2D ultrasound measurements at the individual follicle level.
Secondary objectives include evaluating intra- and inter-observer measurement variability, comparing the time required for manual 2D measurements and the OSIS-based 3D workflow, and assessing agreement in antral follicle counts (AFC) between both methods and their correlation with anti-Müllerian hormone (AMH) levels.
The study will also evaluate the ability of each follicle measurement method to predict the number of mature oocytes (MII) retrieved, based on measurements obtained at the final monitoring visit before ovulation triggering.
Additional analyses will assess the consistency of OSIS performance across different geographical regions, clinical centers, professional profiles, and ultrasound equipment manufacturers, as well as user experience and the learning curve associated with the software.
OSIS is a CE-marked medical device in Europe but has not received U.S. Food and Drug Administration (FDA) clearance. This study is intended to generate clinical evidence regarding the accuracy, reliability, and reproducibility of OSIS in diverse clinical settings and may support future regulatory submissions in the United States.
Typ studie
Typ studie
Zápis (Odhadovaný)
Zápis
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
Women aged 18-45 undergoing controlled ovarian stimulation (COS) for in vitro fertilization (IVF), oocyte donation, or fertility preservation at participating fertility clinics in the United States and Europe.
Eligible participants will be recruited consecutively from women receiving COS at these centers. The study population may include women with infertility as well as healthy oocyte donors.
All participants must meet the protocol-defined inclusion and exclusion criteria and provide written informed consent before undergoing study procedures.
Popis
Inclusion Criteria:
- Female patients aged 18-45 undergoing COS.
- Expected to have ≥5 measurable follicles per ovary
- Signed informed consent
Exclusion Criteria:
- Participation in other clinical trials likely to interfere with this study
- Known ovarian pathology or technical limitations for 3D ultrasound acquisition
- BMI >35 kg/m² (technical limitation for adequate image quality)
- Previous ovarian surgery affecting follicle assessment
Studijní plán
Jak je studie koncipována?
Detaily designu
- Observační modely: COHORT
- Časové perspektivy: PROSPECTIVE
Počet skupin / kohort
Kohorty a intervence
Skupina / kohortaSkupina / kohorta |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Women Undergoing Controlled Ovarian Stimulation (COS)
This cohort includes women undergoing controlled ovarian stimulation (COS) for in vitro fertilization (IVF), oocyte donation, or fertility preservation. All participants will undergo conventional manual 2D ultrasound follicle measurements and 3D transvaginal ultrasound acquisitions during their ovarian stimulation monitoring visits, according to the study protocol. The acquired 3D ultrasound volumes will be processed using OSIS Ovary, an AI-based, CE-marked medical device software for automated ovarian follicle segmentation and measurement. Repeated measurements will be performed to assess intra-observer variability and, where applicable, inter-observer variability. Automated OSIS measurements will be compared with conventional manual 2D ultrasound measurements. All participants will be included in a single observational cohort, without allocation to different ovarian stimulation treatments. |
OSIS Ovary (Online System for Image Segmentation) is AI-based medical device software developed by Fertoolity S.L. that automatically segments and measures ovarian follicles in 3D transvaginal ultrasound images. During controlled ovarian stimulation (COS) monitoring, 3D ovarian volumes will be acquired and processed on the cloud-based OSIS platform to obtain follicle counts, mean diameters, and volumes. OSIS measurements will be compared with conventional manual 2D ultrasound measurements at the individual follicle level to assess agreement and reproducibility. Repeated 2D measurements and 3D acquisitions will assess intra-observer and, where applicable, inter-observer variability. The attending physician will review and validate the datasets. Study procedures will not interfere with clinical management. |
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Agreement Between OSIS and Manual 2D Follicle Diameter Measurements (ICC)
Časové okno: At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).
|
Agreement between paired OSIS-derived 3D and manual 2D mean follicle diameter measurements will be assessed at the individual follicle level using the intraclass correlation coefficient (ICC, unitless). The analysis will account for repeated follicle measurements within participants and variation between centers. |
At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).
|
Sekundární výstupní opatření
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Intra-observer Reproducibility of OSIS Follicle Diameter Measurements (ICC)
Časové okno: At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).
|
Reproducibility of OSIS-derived mean follicle diameter from repeated 3D ultrasound acquisitions performed by the same operator will be measured using the intraclass correlation coefficient (ICC, unitless). |
At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).
|
|
Inter-observer Reproducibility of OSIS Follicle Diameter Measurements (ICC)
Časové okno: At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).
|
Agreement between OSIS-derived mean follicle diameter measurements obtained from 3D volumes acquired by different operators will be assessed using the intraclass correlation coefficient (ICC, unitless). This analysis will be limited to participating centers in the United States, Spain and Portugal. |
At baseline and during ovarian stimulation monitoring (around stimulation days 5, 7, 9 and 11), through the final pre-trigger ultrasound assessment (approximately 14 days per participant).
|
|
Difference in Time Between Manual 2D and OSIS-Based 3D Follicle Assessment (Minutes)
Časové okno: At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
|
The time required to complete manual 2D measurements of both ovaries will be compared with the sum of 3D ovarian volume acquisition time and OSIS automated processing time. The reported measure will be the paired time difference (manual 2D time minus 3D acquisition and OSIS processing time), in minutes. |
At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
|
|
Agreement Between Manual 2D and OSIS Automated Antral Follicle Counts (ICC)
Časové okno: At the baseline ultrasound assessment, within the first 4 days after the onset of menstruation (one assessment per participant).
|
At baseline, the number of antral follicles measuring 2-10 mm identified by manual 2D ultrasound and by automated OSIS analysis of 3D ovarian volumes will be compared. Agreement will be reported as an intraclass correlation coefficient (ICC, unitless). |
At the baseline ultrasound assessment, within the first 4 days after the onset of menstruation (one assessment per participant).
|
|
Mature Oocyte Yield Prediction Error Using OSIS and Manual 2D Ultrasound (MAE)
Časové okno: At the final pre-trigger ultrasound visit and subsequent oocyte retrieval during the same stimulation cycle (approximately 2 weeks).
|
Follicle counts obtained at the final pre-trigger visit using OSIS and manual 2D ultrasound will be used in separate models to predict the number of mature oocytes (MII) retrieved. Prediction accuracy will be reported as mean absolute error (MAE), in number of MII oocytes, for each method. |
At the final pre-trigger ultrasound visit and subsequent oocyte retrieval during the same stimulation cycle (approximately 2 weeks).
|
|
Follicle Diameter Agreement Across Geographic Regions and Operator Profiles (ICC)
Časové okno: At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
|
The intraclass correlation coefficient (ICC, unitless) for agreement between OSIS-derived 3D and manual 2D mean follicle diameter measurements will be estimated by geographic region (United States versus Europe) and operator profile (physicians, nurses or sonographers, where permitted). |
At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
|
|
Follicle Diameter Agreement Across Ultrasound Equipment Manufacturers (ICC)
Časové okno: At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
|
The intraclass correlation coefficient (ICC, unitless) for agreement between OSIS-derived 3D and manual 2D mean follicle diameter measurements will be estimated separately for each ultrasound equipment manufacturer to assess the consistency of software performance across equipment brands. |
At baseline and subsequent ultrasound monitoring visits through the final pre-trigger assessment (approximately 2 weeks per participant).
|
|
OSIS Ovary Ease-of-Use Score (7-Point Likert Scale)
Časové okno: At completion of each operator's study assessments during the data collection period.
|
Healthcare professionals will rate the ease of use of OSIS Ovary on a 7-point Likert scale. The reported outcome is the ease-of-use score (points, 1-7). The association between this score and each user's number of previous OSIS cases will be examined as an indicator of the learning curve. |
At completion of each operator's study assessments during the data collection period.
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Spolupracovníci
Spolupracovníci
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Odhadovaný)
Začátek studia
Primární dokončení (Odhadovaný)
Primární dokončení
Dokončení studie (Odhadovaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
Další identifikační čísla studie
- 2507-BCN-087-EL
- Pro00091234 (Jiný identifikátor: Advarra IRB)
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
produkt vyrobený a vyvážený z USA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .