External Sensors for remoTe MoniToring of Heart Failure Patients With Implantable Defibrillators (ESTIMATE-HF)
External Sensors for remoTe MoniToring of Heart Failure Patients With Implantable Defibrillators: the ESTIMATE-HF Study
Přehled studie
Postavení
Podmínky
Detailní popis
Based on positive outcomes from numerous randomized, controlled trials, the current European Society of Cardiology (ESC) guidelines and current American guidelines for the management of chronic heart failure include the implantable defibrillators as a standard of care in selected chronic heart failure patients .
Heart failure patients with implantable defibrillators often visit the hospital for unscheduled examinations, placing a great burden on healthcare providers. Device manufacturers offer a technology for remote defibrillator monitoring with the purpose of allowing physicians to remotely access patients' data and reducing unnecessary routine and interim visits. The Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study was a multicenter randomized trial designed to assess whether remote management can reduce emergency healthcare use in heart failure patients implanted with defibrillators endowed with specific diagnostic features compared with standard management consisting of scheduled in-office visits and patient response to audible alerts. Over 16 months, the rate of emergency department or urgent in-office visits for heart failure, arrhythmias, or device-related events decreased by 35% and total healthcare visits were 21% less frequent with remote monitoring.
The study confirmed that remote management of heart failure patients implanted with defibrillators allows timely notification of potentially critical situations. Moreover, it has the effect of shifting healthcare visits from the emergency department to the clinic and increasing the appropriateness of in-office visits, thereby reducing costs and the burden on the healthcare system.
Nonetheless, in the EVOLVO study these findings were obtained with defibrillators equipped with specific diagnostic and alerting capabilities, and thus they cannot be fully extended to different technologies. In particular, defibrillators were equipped with these alert capability for the detection of possible fluid accumulation and decompensation, and these alerts accounted for the majority of endpoints recorded during the study.
That alert was shown to be associated with a relatively high rate of false positive detections , and the Diagnostic Outcome Trial in Heart Failure (DOT-HF) recently showed an increased number of hospital admissions among patients with the audible alert enabled.
Alternative systems of RPM (Remote Patient Management) allow recording of the body weight and blood pressure for the management of heart failure. Continuous monitoring of these variables is a fundamental element of the programs of patient monitoring and patient education recommended by the guidelines for the treatment of heart failure.
Although the daily measure of body weight and pressure is present in most telemedicine programs described in the literature , , clinical evidence obtained specifically in the population of patients referred to the implantable defibrillator therapy is scarce. The large observational study ALTITUDE has suggested the possibility of a better prognosis of patients managed via RPM, in particular if provided with sensors for the measurement of weight and pressure.
Typ studie
Zápis (Očekávaný)
Kontakty a umístění
Studijní místa
-
-
-
Pavia, Itálie, 27100
- Policlinico San Matteo
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Patient with left ventricular systolic dysfunction, left ventricular ejection fraction ≤ 35%, as documented at the moment of device implant.
- Patient implanted with a Cardiac Resynchronization Therapy-Defibrillator (CRT-D) or implantable defibrillator (ICD) device.
- Patient must be able and willing to replace regularly-scheduled in-office routine follow-ups with remote follow-ups.
- Patient must be able to attend all required follow-up visits at the study center.
Exclusion Criteria:
- Patient is less than 18 years of age.
- Patient is unwilling or unable to sign an authorization to use and disclose health information or an Informed Consent.
- Patient life expectancy is less than 12 months.
- Patient is participating in another clinical study that may have an impact on the study endpoints.
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
---|
Heart failure patients with ICD
Heart failure patients with ICD and RPM system equipped with sensors for the measurement of weight and pressure
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
---|---|---|
Number of planned and unplanned admissions
Časové okno: 16 months
|
All planned and unplanned hospital and Emergency Department (ED) admissions (not involving an overnight stay) All planned and unplanned hospitalizations (involving an overnight stay or resulting in death)
|
16 months
|
Sekundární výstupní opatření
Měření výsledku |
Časové okno |
---|---|
The number of all cardiac or device related ED visits
Časové okno: 16 months
|
16 months
|
The number of all unplanned cardiac or device related clinic/urgent visits
Časové okno: 16 months
|
16 months
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Vrchní vyšetřovatel: Maurizio Eugenio Landolina, Policlinico San Matteo
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Očekávaný)
Dokončení studie (Očekávaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- 20130004180 del 24/09/2013
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Městnavé srdeční selhání
-
Region SkaneZápis na pozvánkuSrdeční selhání New York Heart Association (NYHA) třída II | Srdeční selhání New York Heart Association (NYHA) třída IIIŠvédsko
-
Medical University of BialystokInstitute of Cardiology, Warsaw, Poland; Medical University of Lodz; Poznan University... a další spolupracovníciZatím nenabírámeSrdeční selhání, systolické | Srdeční Selhání Se Sníženou Ejekční frakcí | Srdeční selhání New York Heart Association Třída IV | Srdeční selhání New York Heart Association Třída IIIPolsko
-
Novartis PharmaceuticalsDokončenoPacienti, kteří úspěšně dokončili 12měsíční léčebné období základní studie (de Novo Heart Recipients), kteří měli zájem o léčbu EC-MPS
-
University of WashingtonAmerican Heart AssociationDokončenoSrdeční selhání, městnavé | Mitochondriální alterace | Srdeční selhání New York Heart Association Třída IVSpojené státy