Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Ideal Depth of Guide Wire for Central Catheterization

8. července 2016 aktualizováno: Jung-Man Lee, Seoul National University Hospital

Ideal Depth of Guide Wire for Right Internal Jugular Vein During Central Line Insertion

prospective randomized double-blind controlled study

Přehled studie

Detailní popis

Total of 69 ASA (American Society of Anesthesiologist) physical status class I or II patients will be enrolled.

Randomly assigned to three group according to the depth of guide-wire prior to tissue dilation during central catheterization via right internal jugular vein. (Group 1: 15 cm / Group 2: 17.5 cm / Group 3: 20 cm)

Central catheterization will be performed by anesthesiologists who be blinded to this study protocol.

An investigator will monitor and record whether any arrhythmia will occur.

The incidence of occurrence of arrhythmia will be compared between three groups.

Typ studie

Intervenční

Zápis (Aktuální)

69

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let a starší (Dospělý, Starší dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

  • patients receiving general anesthesia requiring central venous catheterization via right internal jugular vein.
  • ASA (American Society of Anesthesiologist) physical status class I or II

Exclusion Criteria:

  • at the pre-anesthetic evaluation, history of any arrhythmia
  • when monitoring before the induction of anesthesia in the operating room, newly arrhythmia is observed.
  • abnormal electrolyte at the pre-anesthetic evaluation
  • too difficult to access right internal jugular vein for central catheterization (too short neck, infection at the site of right internal jugular vein, ventriculoperitoneal shunt or chemo-port existence at the site of right internal jugular vein. too close site to operating field)

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Prevence
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Dvojnásobek

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: 15 cm
The depth of guide wire will be 15 cm from puncture site of skin prior to tissue dilation during central venous catheterization

15 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 15 cm.

17.5 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 17.5 cm.

20 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 20 cm.

Experimentální: 17.5 cm
The depth of guide wire will be 17.5 cm from puncture site of skin prior to tissue dilation during central venous catheterization

15 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 15 cm.

17.5 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 17.5 cm.

20 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 20 cm.

Aktivní komparátor: 20 cm
The depth of guide wire will be 20 cm from puncture site of skin prior to tissue dilation during central venous catheterization

15 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 15 cm.

17.5 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 17.5 cm.

20 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 20 cm.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Časové okno
Incidence of arrhythmia
Časové okno: during central venous catheterization
during central venous catheterization

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Ředitel studie: Jung-Man Lee, M.D., Seoul National University Boramae Hospital

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia

1. září 2015

Primární dokončení (Aktuální)

1. března 2016

Dokončení studie (Aktuální)

1. května 2016

Termíny zápisu do studia

První předloženo

14. března 2016

První předloženo, které splnilo kritéria kontroly kvality

14. března 2016

První zveřejněno (Odhad)

17. března 2016

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Odhad)

11. července 2016

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

8. července 2016

Naposledy ověřeno

1. července 2016

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • 16-2015-105

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit