Ideal Depth of Guide Wire for Right Internal Jugular Vein During Central Line Insertion

prospective randomized double-blind controlled study

Przegląd badań

Szczegółowy opis

Total of 69 ASA (American Society of Anesthesiologist) physical status class I or II patients will be enrolled.

Randomly assigned to three group according to the depth of guide-wire prior to tissue dilation during central catheterization via right internal jugular vein. (Group 1: 15 cm / Group 2: 17.5 cm / Group 3: 20 cm)

Central catheterization will be performed by anesthesiologists who be blinded to this study protocol.

An investigator will monitor and record whether any arrhythmia will occur.

The incidence of occurrence of arrhythmia will be compared between three groups.

Typ studiów

Interwencyjne

Zapisy (Rzeczywisty)

69

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

      • Seoul, Republika Korei
        • Seoul National University Boramae Hospital

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat i starsze (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  • patients receiving general anesthesia requiring central venous catheterization via right internal jugular vein.
  • ASA (American Society of Anesthesiologist) physical status class I or II

Exclusion Criteria:

  • at the pre-anesthetic evaluation, history of any arrhythmia
  • when monitoring before the induction of anesthesia in the operating room, newly arrhythmia is observed.
  • abnormal electrolyte at the pre-anesthetic evaluation
  • too difficult to access right internal jugular vein for central catheterization (too short neck, infection at the site of right internal jugular vein, ventriculoperitoneal shunt or chemo-port existence at the site of right internal jugular vein. too close site to operating field)

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Zapobieganie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Podwójnie

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: 15 cm
The depth of guide wire will be 15 cm from puncture site of skin prior to tissue dilation during central venous catheterization

15 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 15 cm.

17.5 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 17.5 cm.

20 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 20 cm.

Eksperymentalny: 17.5 cm
The depth of guide wire will be 17.5 cm from puncture site of skin prior to tissue dilation during central venous catheterization

15 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 15 cm.

17.5 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 17.5 cm.

20 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 20 cm.

Aktywny komparator: 20 cm
The depth of guide wire will be 20 cm from puncture site of skin prior to tissue dilation during central venous catheterization

15 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 15 cm.

17.5 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 17.5 cm.

20 cm: The depth of guide wire prior to tissue dilation during central venous catheterization will be 20 cm.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Ramy czasowe
Incidence of arrhythmia
Ramy czasowe: during central venous catheterization
during central venous catheterization

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Dyrektor Studium: Jung-Man Lee, M.D., Seoul National University Boramae Hospital

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów

1 września 2015

Zakończenie podstawowe (Rzeczywisty)

1 marca 2016

Ukończenie studiów (Rzeczywisty)

1 maja 2016

Daty rejestracji na studia

Pierwszy przesłany

14 marca 2016

Pierwszy przesłany, który spełnia kryteria kontroli jakości

14 marca 2016

Pierwszy wysłany (Oszacować)

17 marca 2016

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Oszacować)

11 lipca 2016

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

8 lipca 2016

Ostatnia weryfikacja

1 lipca 2016

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • 16-2015-105

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj