- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT03764332
Evaluation of the Static Stability of Footwear (EEECS)
Evaluation of the Static Stability of Footwear: A Clinical Trial
Introduction: Postural control is a crucial factor for maintaining balance while standing and walking. The shoe has a role to play in postural stability.
Objectives: To evaluate the static balance of subjects when barefoot and when using three types of footwear with their eyes closed or open.
Material and methods:
Přehled studie
Detailní popis
Each participant was asked to focus on a white mark 2 cm in diameter, positioned on a screen 2 m in front of them at eye level. This was done to standardize the data collection and minimize any variation in postural stability caused by changes in the visual field. Each participant was asked to remain in this position for a period of 30 seconds, while the data was collected. Three repetitions were made for each condition to obtain an average value. The condition on footwear and open / closed eyes was randomized to reduce the learning effect. On the other hand to reduce fatigue, each participant was allowed to rest for 5 minutes between shoe changes.
The size of the sample was calculated with the software of the Clinical Epidemiology and Biostatistics Unit. Complexo Hospitalario Universitario de A Coruña. University of A Coruña (www.fisterra.com). The estimated sample size estimated was calculated to be at least 16 subjects.
Typ studie
Zápis (Aktuální)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
Murcia, Španělsko, 30008
- Clínica López del Amo
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Acceptance and signature of informed consent.
- Persons aged between 25-35 years.
- People with a weight between 40 and 95kg.
- People with a height between 1.50 and 1.90m
Exclusion Criteria:
- People with surgical history of lower limbs.
- People with systemic pathology / algia that can alter the physiological static pattern.
- Congenital deformities or acquired in childhood.
- If after a complete exploration in decubitus, sitting, static standing and gait dynamics, any anomaly that could negatively influence the acquisition of data for the study was detected.
- Patients who do not accept or sign the informed consent
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Prevence
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Jiný: Stabilometry
The Podoprint pressure platform was used as a measuring device.
The Podoprint platform is a low profile floor platform consisting of 1.4 sensors / cm2 with a sampling frequency of 40Hz.
|
To evaluate the static balance of subjects when barefoot and when using three types of footwear with their eyes closed or open.
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Stroke length
Časové okno: 30 seconds
|
Length traveled by the pressure center (CoP), forming a line called oscillatory ball. In mm. The Podoprint pressure platform was used as a measuring device. Quantitative variable |
30 seconds
|
|
Stroke surface
Časové okno: 30 seconds
|
Area of the smallest ellipse able to encompass the oscillating ball. In mm. The Podoprint pressure platform was used as a measuring device. Quantitative variable |
30 seconds
|
|
Relationship between Length / surface
Časové okno: 30 seconds
|
Value resulting from the relationship between the two previous measures. The Podoprint pressure platform was used as a measuring device. Quantitative variable |
30 seconds
|
|
Average swing speed
Časové okno: 30 seconds
|
Average speed that reaches the displacement of the center of pressures. The Podoprint pressure platform was used as a measuring device. Quantitative variable |
30 seconds
|
|
Lateral velocity
Časové okno: 30 seconds
|
Average speed of oscillation in its axis of ordinates.
The Podoprint pressure platform was used as a measuring device.
Quantitative variable
|
30 seconds
|
|
Forward speed
Časové okno: 30 seconds
|
Average oscillation speed on its abscissa axis.
The Podoprint pressure platform was used as a measuring device.
Quantitative variable
|
30 seconds
|
|
Average displacement in the X axis
Časové okno: 30 seconds
|
Average of the displacements made by the center of pressures in the axis of ordinates. The Podoprint pressure platform was used as a measuring device. Quantitative variable |
30 seconds
|
|
Average displacement on the Y axis
Časové okno: 30 seconds
|
Average of the displacements made by the center of pressures on the abscissa axis. The Podoprint pressure platform was used as a measuring device. Quantitative variable |
30 seconds
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Vrchní vyšetřovatel: Jose Sanchez Saez, Podólogo, Universidade da Coruña
Publikace a užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .