Computed tomography model-based treatment of atrial fibrillation and atrial macro-re-entrant tachycardia
Christopher Piorkowski, Simon Kircher, Arash Arya, Thomas Gaspar, Masahiro Esato, Sam Riahi, Andreas Bollmann, Daniela Husser, Charlotte Staab, Philipp Sommer, Gerhard Hindricks, Christopher Piorkowski, Simon Kircher, Arash Arya, Thomas Gaspar, Masahiro Esato, Sam Riahi, Andreas Bollmann, Daniela Husser, Charlotte Staab, Philipp Sommer, Gerhard Hindricks
Abstract
Aims: Accurate orientation within true three-dimensional (3D) anatomies is essential for the successful radiofrequency (RF) catheter ablation of atrial fibrillation (AF) and atrial macro-re-entrant tachycardia (MRT). In this prospective study, ablation of AF and MRT was performed exclusively using a pre-acquired and integrated computed tomography (CT) image for anatomical 3D orientation without electro-anatomic reconstruction of the left atrium (LA).
Methods and results: Fifty-four consecutive patients suffering from AF (n = 36) and/or MRT (n = 18) underwent RF catheter ablation. A 3D CT image was registered into the NavX-Ensite system without reconstruction of the atrial chamber anatomy. The quality of CT alignment was assessed and validated according to fluoroscopy information, electrogram characteristics, and tactile feedback at 31 pre-defined LA control points. The ablation of AF as well as mapping and ablation of MRT was performed within the 3D CT anatomy. In all patients, mapping and ablation could be performed without the reconstruction of the respective atrial chamber anatomy. The overall CT alignment was highly accurate with true surface contact in 90% (84%; 100%) of the control points. Complete isolation of all pulmonary vein (PV) funnels was achieved in 35 of 36 patients (97%) with AF. In patients with persistent AF (n = 11), additional isolation of the posterior LA (box lesion) and the placement of a mitral isthmus line were performed. The MRT mechanisms were as follows: around a PV ostium (n = 6), perimitral (n = 4), through LA roof (n = 5), septal (n = 2), and around left atrial appendage (n = 1). After a follow-up of 122 +/- 33 days, 22/25 (88%) patients with paroxysmal AF, 8/11 (73%) with persistent AF, and 16/18 (89%) with MRT remained free from arrhythmia recurrences.
Conclusion: For patients with AF and MRT, our study shows the feasibility of successful placement of complex linear ablation line concepts guided by an integrated 3D image anatomy alone rather than catheter-based virtual chamber surface reconstructions.
Keywords: Ablation; Atrial fibrillation; Model-guided therapy; Three dimensional image.
Figures
References
- Ben-Haim SA, Osadchy D, Schuster I, Hayam G, Josephson ME. Nonfluoroscopic, in vivo navigation and mapping technology. Nat Med. 1996;2:1393–5.
- Krum D, Goel A, Hauck J, Schweitzer J, Hare J, Attari M, et al. Catheter location, tracking, cardiac chamber geometry creation, and ablation using cutaneous patches. J Interv Card Electrophysiol. 2005;12:17–22.
- Piorkowski C, Hindricks G, Schreiber D, Tanner H, Weise W, Koch A, et al. Electroanatomic reconstruction of the left atrium, pulmonary veins, and esophagus compared with the ‘true anatomy’ on multislice computed tomography in patients undergoing catheter ablation of atrial fibrillation. Heart Rhythm. 2006;3:317–27.
- Dong J, Dickfeld T, Dalal D, Cheema A, Vasamreddy CR, Henrikson CA, et al. Initial experience in the use of integrated electroanatomic mapping with three-dimensional MR/CT images to guide catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2006;17:459–66.
- Kistler PM, Rajappan K, Jahngir M, Earley MJ, Harris S, Abrams D, et al. The impact of CT image integration into an electroanatomic mapping system on clinical outcomes of catheter ablation of atrial fibrillation. J Cardiovasc Electrophysiol. 2006;17:1093–101.
- Shalganov TN, Vatasescu R, Paprika D, Kornyei L, Vanyi J, Geller L, et al. A simple algorithm for defining the mechanism and the chamber of origin in atrial tachycardias. J Electrocardiol. 2006;39:369–76.
- Kottkamp H, Piorkowski C, Tanner H, Kobza R, Dorszewski A, Schirdewahn P, et al. Topographic variability of the esophageal left atrial relation influencing ablation lines in patients with atrial fibrillation. J Cardiovasc Electrophysiol. 2005;16:146–50.
- Heist EK, Chevalier J, Holmvang G, Singh JP, Ellinor PT, Milan DJ, et al. Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation. J Interv Card Electrophysiol. 2006;17:21–7.
- Ferguson J. Optimizing catheter navigation for AF ablation: do not just follow the map! J Cardiovasc Electrophysiol. 2007;18:283–5.
- Zhong H, Lacomis JM, Schwartzman D. On the accuracy of CartoMerge for guiding posterior left atrial ablation in man. Heart Rhythm. 2007;4:595–602.
- Fahmy TS, Mlcochova H, Wazni OM, Patel D, Cihak R, Kanj M, et al. Intracardiac echo-guided image integration: optimizing strategies for registration. J Cardiovasc Electrophysiol. 2007;18:276–82.
- Brooks AG, Wilson L, Kuklik P, Stiles MK, John B, Hany Dimitri S, et al. Image integration using NavX Fusion: initial experience and validation. Heart Rhythm. 2008;5:526–35.