Usability of Wearable Devices With a Novel Cardiac Force Index for Estimating the Dynamic Cardiac Function: Observational Study

Po-Jen Hsiao, Chih-Chien Chiu, Ke-Hsin Lin, Fu-Kang Hu, Pei-Jan Tsai, Chun-Ting Wu, Yuan-Kai Pang, Yu Lin, Ming-Hao Kuo, Kang-Hua Chen, Yi-Syuan Wu, Hao-Yi Wu, Ya-Ting Chang, Yu-Tien Chang, Chia-Shiang Cheng, Chih-Pin Chuu, Fu-Huang Lin, Chi-Wen Chang, Yuan-Kuei Li, Jenq-Shyong Chan, Chi-Ming Chu, Po-Jen Hsiao, Chih-Chien Chiu, Ke-Hsin Lin, Fu-Kang Hu, Pei-Jan Tsai, Chun-Ting Wu, Yuan-Kai Pang, Yu Lin, Ming-Hao Kuo, Kang-Hua Chen, Yi-Syuan Wu, Hao-Yi Wu, Ya-Ting Chang, Yu-Tien Chang, Chia-Shiang Cheng, Chih-Pin Chuu, Fu-Huang Lin, Chi-Wen Chang, Yuan-Kuei Li, Jenq-Shyong Chan, Chi-Ming Chu

Abstract

Background: Long-distance running can be a form of stress to the heart. Technological improvements combined with the public's gradual turn toward mobile health (mHealth), self-health, and exercise effectiveness have resulted in the widespread use of wearable exercise products. The monitoring of dynamic cardiac function changes during running and running performance should be further studied.

Objective: We investigated the relationship between dynamic cardiac function changes and finish time for 3000-meter runs. Using a wearable device based on a novel cardiac force index (CFI), we explored potential correlations among 3000-meter runners with stronger and weaker cardiac functions during running.

Methods: This study used the American product BioHarness 3.0 (Zephyr Technology Corporation), which can measure basic physiological parameters including heart rate, respiratory rate, temperature, maximum oxygen consumption, and activity. We investigated the correlations among new physiological parameters, including CFI = weight * activity / heart rate, cardiac force ratio (CFR) = CFI of running / CFI of walking, and finish times for 3000-meter runs.

Results: The results showed that waist circumference, smoking, and CFI were the significant factors for qualifying in the 3000-meter run. The prediction model was as follows: ln (3000 meters running performance pass probability / fail results probability) = -2.702 - 0.096 × [waist circumference] - 1.827 × [smoke] + 0.020 × [ACi7]. If smoking and the ACi7 were controlled, contestants with a larger waist circumference tended to fail the qualification based on the formula above. If waist circumference and ACi7 were controlled, smokers tended to fail more often than nonsmokers. Finally, we investigated a new calculation method for monitoring cardiac status during exercise that uses the CFI of walking for the runner as a reference to obtain the ratio between the cardiac force of exercise and that of walking (CFR) to provide a standard for determining if the heart is capable of exercise. A relationship is documented between the CFR and the performance of 3000-meter runs in a healthy 22-year-old person. During the running period, data are obtained while participant slowly runs 3000 meters, and the relationship between the CFR and time is plotted. The runner's CFR varies with changes in activity. Since the runner's acceleration increases, the CFR quickly increases to an explosive peak, indicating the runner's explosive power. At this period, the CFI revealed a 3-fold increase (CFR=3) in a strong heart. After a time lapse, the CFR is approximately 2.5 during an endurance period until finishing the 3000-meter run. Similar correlation is found in a runner with a weak heart, with the CFR at the beginning period being 4 and approximately 2.5 thereafter.

Conclusions: In conclusion, the study results suggested that measuring the real-time CFR changes could be used in a prediction model for 3000-meter running performance.

Keywords: acceleration; cardiac force; heart rate; physical activity; running.

Conflict of interest statement

Conflicts of Interest: None declared.

©Po-Jen Hsiao, Chih-Chien Chiu, Ke-Hsin Lin, Fu-Kang Hu, Pei-Jan Tsai, Chun-Ting Wu, Yuan-Kai Pang, Yu Lin, Ming-Hao Kuo, Kang-Hua Chen, Yi-Syuan Wu, Hao-Yi Wu, Ya-Ting Chang, Yu-Tien Chang, Chia-Shiang Cheng, Chih-Pin Chuu, Fu-Huang Lin, Chi-Wen Chang, Yuan-Kuei Li, Jenq-Shyong Chan, Chi-Ming Chu. Originally published in JMIR mHealth and uHealth (http://mhealth.jmir.org), 21.07.2020.

Figures

Figure 1
Figure 1
The process of collecting data followed six steps in this study.
Figure 2
Figure 2
Runner with stronger cardiac force during 3000-meter running.
Figure 3
Figure 3
Runner with weaker cardiac force during 3000-meter running.

References

    1. Platen P, Schaar B. How to carry out a health-orientated marathon training programme for running and inline skating. Eur J Cardiovasc Prev Rehabil. 2003 Aug;10(4):304–312. doi: 10.1097/00149831-200308000-00015.
    1. Nystoriak MA, Bhatnagar A. Cardiovascular effects and benefits of exercise. Front Cardiovasc Med. 2018;5:135. doi: 10.3389/fcvm.2018.00135. doi: 10.3389/fcvm.2018.00135.
    1. Hu FB, Manson JE, Stampfer MJ, Colditz G, Liu S, Solomon CG, Willett WC. Diet, lifestyle, and the risk of type 2 diabetes mellitus in women. N Engl J Med. 2001 Sep 13;345(11):790–797. doi: 10.1056/NEJMoa010492.
    1. Stampfer MJ, Hu FB, Manson JE, Rimm EB, Willett WC. Primary prevention of coronary heart disease in women through diet and lifestyle. N Engl J Med. 2000 Jul 06;343(1):16–22. doi: 10.1056/NEJM200007063430103.
    1. Nikolaidis PT, Rosemann T, Knechtle B. A brief review of personality in marathon runners: the role of sex, age and performance level. Sports (Basel) 2018 Sep 18;6(3) doi: 10.3390/sports6030099.
    1. Nikolaidis PT, Rosemann T, Knechtle B. Sex differences in the age of peak marathon race time. Chin J Physiol. 2018 Apr 30;61(2):85–91. doi: 10.4077/CJP.2018.BAG535.
    1. Jokl P, Sethi PM, Cooper AJ. Master's performance in the New York City Marathon 1983-1999. Br J Sports Med. 2004 Aug;38(4):408–412. doi: 10.1136/bjsm.2002.003566.
    1. La Gerche A, Heidbuchel H. Can intensive exercise harm the heart? You can get too much of a good thing. Circulation. 2014 Sep 16;130(12):992–1002. doi: 10.1161/CIRCULATIONAHA.114.008141.
    1. Herm J, Töpper A, Wutzler A, Kunze C, Krüll M, Brechtel L, Lock J, Fiebach JB, Heuschmann PU, Haverkamp W, Endres M, Jungehulsing GJ, Haeusler KG. Frequency of exercise-induced ST-T-segment deviations and cardiac arrhythmias in recreational endurance athletes during a marathon race: results of the prospective observational Berlin Beat of Running study. BMJ Open. 2017 Aug 03;7(8):e015798. doi: 10.1136/bmjopen-2016-015798.
    1. Spada TC, Silva JMRD, Francisco LS, Marçal LJ, Antonangelo L, Zanetta DMT, Yu L, Burdmann EA. High intensity resistance training causes muscle damage and increases biomarkers of acute kidney injury in healthy individuals. PLoS One. 2018;13(11):e0205791. doi: 10.1371/journal.pone.0205791.
    1. Kim JH, Malhotra R, Chiampas G, d'Hemecourt P, Troyanos C, Cianca J, Smith RN, Wang TJ, Roberts WO, Thompson PD, Baggish AL, Race Associated Cardiac Arrest Event Registry (RACER) Study Group Cardiac arrest during long-distance running races. N Engl J Med. 2012 Jan 12;366(2):130–140. doi: 10.1056/NEJMoa1106468.
    1. Kiyohara K, Nishiyama C, Kiguchi T, Nishiuchi T, Hayashi Y, Iwami T, Kitamura T. Exercise-related out-of-hospital cardiac arrest among the general population in the era of public-access defibrillation: a population-based observation in japan. J Am Heart Assoc. 2017 Jun 13;6(6) doi: 10.1161/JAHA.117.005786.
    1. Roberts WO, Roberts DM, Lunos S. Marathon related cardiac arrest risk differences in men and women. Br J Sports Med. 2013 Feb;47(3):168–171. doi: 10.1136/bjsports-2012-091119.
    1. Hart L. Marathon-related cardiac arrest. Clin J Sport Med. 2013 Sep;23(5):409–410. doi: 10.1097/01.jsm.0000433155.97054.c8.
    1. Degroote L, De Bourdeaudhuij I, Verloigne M, Poppe L, Crombez G. The accuracy of smart devices for measuring physical activity in daily life: validation study. JMIR Mhealth Uhealth Dec 13. 2018;6(12):e10972. doi: 10.2196/10972.
    1. Mackintosh KA, Chappel SE, Salmon J, Timperio A, Ball K, Brown H, Macfarlane S, Ridgers ND. Parental perspectives of a wearable activity tracker for children younger than 13 years: acceptability and usability study. JMIR Mhealth Uhealth. 2019 Nov 04;7(11):e13858. doi: 10.2196/13858.
    1. Islam SMS, Cartledge S, Karmakar C, Rawstorn JC, Fraser SF, Chow C, Maddison R. Validation and acceptability of a cuffless wrist-worn wearable blood pressure monitoring device among users and health care professionals: mixed methods study. JMIR Mhealth Uhealth. 2019 Sep 14;7(10):e14706. doi: 10.2196/14706.
    1. Graham SA, Jeste DV, Lee EE, Wu T, Tu X, Kim H, Depp CA. Associations between heart rate variability measured with a wrist-worn sensor and older adults' physical function: observational study. JMIR Mhealth Uhealth. 2019 Oct 23;7(10):e13757. doi: 10.2196/13757.
    1. Thorpe J, Forchhammer BH, Maier AM. Adapting mobile and wearable technology to provide support and monitoring in rehabilitation for dementia: feasibility case series. JMIR Form Res. 2019 Oct 17;3(4):e12346. doi: 10.2196/12346.
    1. Villarejo MV, Zapirain BG, Zorrilla AM. Algorithms based on CWT and classifiers to control cardiac alterations and stress using an ECG and a SCR. Sensors (Basel) 2013 May 10;13(5):6141–6170. doi: 10.3390/s130506141.
    1. Arif M, Kattan A. Physical activities monitoring using wearable acceleration sensors attached to the body. PLoS One. 2015;10(7):e0130851. doi: 10.1371/journal.pone.0130851.
    1. Papi E, Murtagh GM, McGregor AH. Wearable technologies in osteoarthritis: a qualitative study of clinicians' preferences. BMJ Open. 2016 Jan 25;6(1):e009544. doi: 10.1136/bmjopen-2015-009544.
    1. Ahamed NU, Kobsar D, Benson L, Clermont C, Kohrs R, Osis ST, Ferber R. Using wearable sensors to classify subject-specific running biomechanical gait patterns based on changes in environmental weather conditions. PLoS One. 2018;13(9):e0203839. doi: 10.1371/journal.pone.0203839.
    1. Rodríguez-Molina J, Martínez J, Castillejo P, López L. Combining wireless sensor networks and semantic middleware for an Internet of Things-based sportsman/woman monitoring application. Sensors (Basel) 2013 Jan 31;13(2):1787–1835. doi: 10.3390/s130201787.
    1. Nazari G, Bobos P, MacDermid JC, Sinden KE, Richardson J, Tang A. Psychometric properties of the Zephyr bioharness device: a systematic review. BMC Sports Sci Med Rehabil. 2018;10:6. doi: 10.1186/s13102-018-0094-4.
    1. Nazari G, MacDermid JC, Sinden KE, Richardson J, Tang A. Reliability of Zephyr Bioharness and Fitbit Charge measures of heart rate and activity at rest, during the modified Canadian aerobic fitness test, and recovery. J Strength Cond Res. 2019 Feb;33(2):559–571. doi: 10.1519/JSC.0000000000001842.
    1. Johnstone JA, Ford PA, Hughes G, Watson T, Mitchell ACS, Garrett AT. Field based reliability and validity of the bioharness™ multivariable monitoring device. J Sports Sci Med. 2012;11(4):643–652.
    1. Lin S, Sung W, Kuo F, Kuo TBJ, Chen J. Impact of center-of-mass acceleration on the performance of ultramarathon runners. J Hum Kinet. 2014 Dec 09;44:41–52. doi: 10.2478/hukin-2014-0109.
    1. Chu. CM Method for detecting cardiac status, method for monitoring cardiac status during exercise, and apparatus for monitoring cardiac status. United States Patent Office. 2016. [2020-05-13]. .
    1. Chu. CM Method for detecting cardiac status, method for monitoring cardiac status during exercise, and apparatus for monitoring cardiac status. Taiwan Patent 2016; No. 408 I546051. 2016
    1. Leyk D, Erley O, Gorges W, Ridder D, Rüther T, Wunderlich M, Sievert A, Essfeld D, Piekarski C, Erren T. Performance, training and lifestyle parameters of marathon runners aged 20-80 years: results of the PACE-study. Int J Sports Med. 2009 May;30(5):360–365. doi: 10.1055/s-0028-1105935.
    1. Marti B, Abelin T, Minder CE. Relationship of training and life-style to 16-km running time of 4000 joggers. The '84 Berne. Int J Sports Med. 1988 Apr;9(2):85–91. doi: 10.1055/s-2007-1024984.
    1. Lara B, Salinero JJ, Del Coso J. The relationship between age and running time in elite marathoners is U-shaped. Age (Dordr) 2014 Apr;36(2):1003–1008. doi: 10.1007/s11357-013-9614-z.
    1. Knechtle B, Assadi H, Lepers R, Rosemann T, Rüst C. Relationship between age and elite marathon race time in world single age records from 5 to 93 years. BMC Sports Sci Med Rehabil. 2014;6:31. doi: 10.1186/2052-1847-6-31.
    1. Liang J, Wang Y, Li H, Liu X, Qiu Q, Qi L. Neck circumference and early stage atherosclerosis: the cardiometabolic risk in Chinese (CRC) study. Cardiovasc Diabetol. 2014 Jul 08;13:107. doi: 10.1186/s12933-014-0107-x.
    1. Liu Y, Chang S, Lin W, Hsu J, Chung C, Chang J, Hung K, Chen K, Chang C, Chen F, Shih Y, Chu C. Neck circumference as a predictive indicator of CKD for high cardiovascular risk patients. Biomed Res Int. 2015;2015:745410. doi: 10.1155/2015/745410. doi: 10.1155/2015/745410.
    1. Hsiao P, Lin H, Chang S, Hsu J, Lin W, Chung C, Chang J, Hung K, Shih Y, Chen F, Hu F, Wu Y, Chang C, Su S, Chu C. Albuminuria and neck circumference are determinate factors of successful accurate estimation of glomerular filtration rate in high cardiovascular risk patients. PLoS One. 2018;13(2):e0185693. doi: 10.1371/journal.pone.0185693.

Source: PubMed

3