Feasibility and Acceptability of Wearable Sleep Electroencephalogram Device Use in Adolescents: Observational Study

Jessica R Lunsford-Avery, Casey Keller, Scott H Kollins, Andrew D Krystal, Leah Jackson, Matthew M Engelhard, Jessica R Lunsford-Avery, Casey Keller, Scott H Kollins, Andrew D Krystal, Leah Jackson, Matthew M Engelhard

Abstract

Background: Adolescence is an important life stage for the development of healthy behaviors, which have a long-lasting impact on health across the lifespan. Sleep undergoes significant changes during adolescence and is linked to physical and psychiatric health; however, sleep is rarely assessed in routine health care settings. Wearable sleep electroencephalogram (EEG) devices may represent user-friendly methods for assessing sleep among adolescents, but no studies to date have examined the feasibility and acceptability of sleep EEG wearables in this age group.

Objective: The goal of the research was to investigate the feasibility and acceptability of sleep EEG wearable devices among adolescents aged 11 to 17 years.

Methods: A total of 104 adolescents aged 11 to 17 years participated in 7 days of at-home sleep recording using a self-administered wearable sleep EEG device (Zmachine Insight+, General Sleep Corporation) as well as a wristworn actigraph. Feasibility was assessed as the number of full nights of successful recording completed by adolescents, and acceptability was measured by the wearable acceptability survey for sleep. Feasibility and acceptability were assessed separately for the sleep EEG device and wristworn actigraph.

Results: A total of 94.2% (98/104) of adolescents successfully recorded at least 1 night of data using the sleep EEG device (mean number of nights 5.42; SD 1.71; median 6, mode 7). A total of 81.6% (84/103) rated the comfort of the device as falling in the comfortable to mildly uncomfortable range while awake. A total of 40.8% (42/103) reported typical sleep while using the device, while 39.8% (41/103) indicated minimal to mild device-related sleep disturbances. A minority (32/104, 30.8%) indicated changes in their sleep position due to device use, and very few (11/103, 10.7%) expressed dissatisfaction with their experience with the device. A similar pattern was observed for the wristworn actigraph device.

Conclusions: Wearable sleep EEG appears to represent a feasible, acceptable method for sleep assessment among adolescents and may have utility for assessing and treating sleep disturbances at a population level. Future studies with adolescents should evaluate strategies for further improving usability of such devices, assess relationships between sleep EEG-derived metrics and health outcomes, and investigate methods for incorporating data from these devices into emerging digital interventions and applications.

Trial registration: ClinicalTrials.gov NCT03843762; https://ichgcp.net/clinical-trials-registry/NCT03843762.

Keywords: EEG; acceptability; actigraphy; adolescents; feasibility; mHealth; sleep; tolerability; wearable.

Conflict of interest statement

Conflicts of Interest: Authors do not have any conflicts of interest to report in regard to the devices used in this study. ADK has received research funding from Janssen Pharmaceuticals, Axsome Pharmaceutics, Reveal Biosensors, The Ray and Dagmar Dolby Family Fund, and the National Institutes of Health. He has received consulting fees from Adare, Axsome Therapeutics, Big Data, Eisai, Evecxia, Ferring Pharmaceuticals, Galderma, Harmony Biosciences, Janssen Pharmaceuticals, Jazz Pharmaceuticals, Millennium Pharmaceuticals, Merck, Neurocrine Biosciences, Pernix, Otsuka Pharmaceuticals, Sage, and Takeda. Authors JRLA, CEK, SHK, LJ, and MME do not have any conflicts of interest to report.

©Jessica R Lunsford-Avery, Casey Keller, Scott H Kollins, Andrew D Krystal, Leah Jackson, Matthew M Engelhard. Originally published in JMIR mHealth and uHealth (http://mhealth.jmir.org), 01.10.2020.

Figures

Figure 1
Figure 1
Number of nights of successful sleep recording by sleep device.
Figure 2
Figure 2
Ratings of comfort for sleep wearables while awake and sleeping.
Figure 3
Figure 3
Wearable-related sleep disturbances by device.
Figure 4
Figure 4
Endorsement of wearable-related changes in sleep position by device.
Figure 5
Figure 5
Overall study satisfaction by device.
Figure 6
Figure 6
Number of adolescents recommending study to a friend by device.

References

    1. Sawyer SM, Afifi RA, Bearinger LH, Blakemore S, Dick B, Ezeh AC, Patton GC. Adolescence: a foundation for future health. Lancet. 2012 Apr 28;379(9826):1630–1640. doi: 10.1016/S0140-6736(12)60072-5.
    1. Crowley SJ, Wolfson AR, Tarokh L, Carskadon MA. An update on adolescent sleep: new evidence informing the perfect storm model. J Adolesc. 2018 Aug;67:55–65. doi: 10.1016/j.adolescence.2018.06.001.
    1. Owens J, Adolescent Sleep Working Group. Committee on Adolescence Insufficient sleep in adolescents and young adults: an update on causes and consequences. Pediatrics. 2014 Sep;134(3):e921–e932. doi: 10.1542/peds.2014-1696.
    1. Garbarino S, Lanteri P, Durando P, Magnavita N, Sannita WG. Co-morbidity, mortality, quality of life and the healthcare/welfare/social costs of disordered sleep: a rapid review. Int J Environ Res Public Health. 2016 Aug 18;13(8) doi: 10.3390/ijerph13080831.
    1. Meltzer LJ, Plaufcan MR, Thomas JH, Mindell JA. Sleep problems and sleep disorders in pediatric primary care: treatment recommendations, persistence, and health care utilization. J Clin Sleep Med. 2014 Apr 15;10(4):421–426. doi: 10.5664/jcsm.3620. doi: 10.5664/jcsm.3620.
    1. Perry GS, Patil SP, Presley-Cantrell LR. Raising awareness of sleep as a healthy behavior. Prev Chronic Dis. 2013 Aug 08;10:E133. doi: 10.5888/pcd10.130081.
    1. Van de Water ATM, Holmes A, Hurley DA. Objective measurements of sleep for non-laboratory settings as alternatives to polysomnography: a systematic review. J Sleep Res. 2011 Mar;20(1 Pt 2):183–200. doi: 10.1111/j.1365-2869.2009.00814.x. doi: 10.1111/j.1365-2869.2009.00814.x.
    1. Lee AM, Chavez S, Bian J, Thompson LA, Gurka MJ, Williamson VG, Modave F. Efficacy and effectiveness of mobile health technologies for facilitating physical activity in adolescents: scoping review. JMIR Mhealth Uhealth. 2019 Feb 12;7(2):e11847. doi: 10.2196/11847.
    1. Jeminiwa RN, Hohmann NS, Fox BI. Developing a theoretical framework for evaluating the quality of mHealth apps for adolescent users: a systematic review. J Pediatr Pharmacol Ther. 2019;24(4):254–269. doi: 10.5863/1551-6776-24.4.254.
    1. Ridgers ND, McNarry MA, Mackintosh KA. Feasibility and effectiveness of using wearable activity trackers in youth: a systematic review. JMIR Mhealth Uhealth. 2016 Nov 23;4(4):e129. doi: 10.2196/mhealth.6540.
    1. Stores G, Crawford C, Selman J, Wiggs L. Home polysomnography norms for children. Technol Health Care. 1998 Nov;6(4):231–236.
    1. Sadeh A. The role and validity of actigraphy in sleep medicine: an update. Sleep Med Rev. 2011 Aug;15(4):259–267. doi: 10.1016/j.smrv.2010.10.001.
    1. Meltzer LJ, Montgomery-Downs HE, Insana SP, Walsh CM. Use of actigraphy for assessment in pediatric sleep research. Sleep Med Rev. 2012 Oct;16(5):463–475. doi: 10.1016/j.smrv.2011.10.002.
    1. Piwek L, Ellis DA, Andrews S, Joinson A. The rise of consumer health wearables: promises and barriers. PLoS Med. 2016 Feb;13(2):e1001953. doi: 10.1371/journal.pmed.1001953.
    1. Liang Z, Chapa-Martell MA. Accuracy of Fitbit wristbands in measuring sleep stage transitions and the effect of user-specific factors. JMIR Mhealth Uhealth. 2019 Jun 06;7(6):e13384. doi: 10.2196/13384.
    1. Feinberg I, de Bie E, Davis NM, Campbell IG. Topographic differences in the adolescent maturation of the slow wave EEG during NREM sleep. Sleep. 2011 Mar 01;34(3):325–333. doi: 10.1093/sleep/34.3.325.
    1. Baker FC, Turlington SR, Colrain I. Developmental changes in the sleep electroencephalogram of adolescent boys and girls. J Sleep Res. 2012 Feb;21(1):59–67. doi: 10.1111/j.1365-2869.2011.00930.x. doi: 10.1111/j.1365-2869.2011.00930.x.
    1. Brand S, Gerber M, Beck J, Hatzinger M, Pühse U, Holsboer-Trachsler E. Exercising, sleep-EEG patterns, and psychological functioning are related among adolescents. World J Biol Psychiatry. 2010 Mar;11(2):129–140. doi: 10.3109/15622970903522501.
    1. Brand S, Beck J, Gerber M, Hatzinger M, Holsboer-Trachsler E. Evidence of favorable sleep-EEG patterns in adolescent male vigorous football players compared to controls. World J Biol Psychiatry. 2010 Mar;11(2 Pt 2):465–475. doi: 10.1080/15622970903079820.
    1. Awad KM, Drescher AA, Malhotra A, Quan SF. Effects of exercise and nutritional intake on sleep architecture in adolescents. Sleep Breath. 2013 Mar;17(1):117–124. doi: 10.1007/s11325-012-0658-6.
    1. Santangeli O, Porkka-Heiskanen T, Virkkala J, Castaneda AE, Marttunen M, Paunio T, Urrila AS. Sleep and slow-wave activity in depressed adolescent boys: a preliminary study. Sleep Med. 2017 Oct;38:24–30. doi: 10.1016/j.sleep.2017.06.029.
    1. Stores G, Fry A, Crawford C. Sleep abnormalities demonstrated by home polysomnography in teenagers with chronic fatigue syndrome. J Psychosom Res. 1998 Jul;45(1):85–91. doi: 10.1016/s0022-3999(98)00024-5.
    1. Perfect MM, Levine-Donnerstein D, Archbold K, Goodwin JL, Quan SF. The contribution of sleep problems to academic and psychosocial functioning. Psychol Schools. 2014 Jan 28;51(3):273–295. doi: 10.1002/pits.21746.
    1. Bianchi MT. Sleep devices: wearables and nearables, informational and interventional, consumer and clinical. Metabolism. 2018 Dec;84:99–108. doi: 10.1016/j.metabol.2017.10.008.
    1. Wang Y, Loparo KA, Kelly MR, Kaplan RF. Evaluation of an automated single-channel sleep staging algorithm. Nat Sci Sleep. 2015;7:101–111. doi: 10.2147/NSS.S77888. doi: 10.2147/NSS.S77888.
    1. Kaplan RF, Wang Y, Loparo KA, Kelly MR, Bootzin RR. Performance evaluation of an automated single-channel sleep-wake detection algorithm. Nat Sci Sleep. 2014;6:113–122. doi: 10.2147/NSS.S71159. doi: 10.2147/NSS.S71159.
    1. Szczygiel EJ, Cho S, Tucker RM. Multiple dimensions of sweet taste perception altered after sleep curtailment. Nutrients. 2019 Aug 27;11(9) doi: 10.3390/nu11092015.
    1. Dunn LK, Kleiman AM, Forkin KT, Bechtel AJ, Collins SR, Potter JF, Kaperak CJ, Tsang S, Huffmyer JL, Nemergut EC. Anesthesiology resident night float duty alters sleep patterns: an observational study. Anesthesiology. 2019 Aug;131(2):401–409. doi: 10.1097/ALN.0000000000002806.
    1. Wohlgemuth WK, Edinger JD, Fins AI, Sullivan RJ. How many nights are enough? The short-term stability of sleep parameters in elderly insomniacs and normal sleepers. Psychophysiology. 1999 Mar;36(2):233–244.
    1. Acebo C, Sadeh A, Seifer R, Tzischinsky O, Wolfson AR, Hafer A, Carskadon MA. Estimating sleep patterns with activity monitoring in children and adolescents: how many nights are necessary for reliable measures? Sleep. 1999 Feb 01;22(1):95–103. doi: 10.1093/sleep/22.1.95.
    1. Carney CE, Buysse DJ, Ancoli-Israel S, Edinger JD, Krystal AD, Lichstein KL, Morin CM. The consensus sleep diary: standardizing prospective sleep self-monitoring. Sleep. 2012 Feb 01;35(2):287–302. doi: 10.5665/sleep.1642. doi: 10.5665/sleep.1642.
    1. Dieffenderfer J, Krystal A, Bozkurt A. Shedding light to sleep studies. Proc SPIE. 2017;10352 doi: 10.1117/12.2275625.
    1. Lunsford-Avery JR, Kollins SH, Krystal AD. Sleeping at home: feasibility and tolerability of ambulatory polysomnography for use with adolescents with attention-deficit/hyperactivity disorder. Sleep. 2018 Apr;41:A283–A284. doi: 10.1093/sleep/zsy061.761.
    1. Brand S, Kirov R. Sleep and its importance in adolescence and in common adolescent somatic and psychiatric conditions. Int J Gen Med. 2011;4:425–442. doi: 10.2147/IJGM.S11557. doi: 10.2147/IJGM.S11557.
    1. Dutil C, Chaput J. Inadequate sleep as a contributor to type 2 diabetes in children and adolescents. Nutr Diabetes. 2017 May 08;7(5):e266. doi: 10.1038/nutd.2017.19.
    1. Khassawneh B, Tsai SC, Meltzer LJ. Polysomnographic characteristics of adolescents with asthma and low risk for sleep-disordered breathing. Sleep Breath. 2019 Sep;23(3):943–951. doi: 10.1007/s11325-018-01774-3.
    1. Augustinavicius JLS, Zanjani A, Zakzanis KK, Shapiro CM. Polysomnographic features of early-onset depression: a meta-analysis. J Affect Disord. 2014 Apr;158:11–18. doi: 10.1016/j.jad.2013.12.009.
    1. Anderson M, Jiang J. Teens, social media & technology. Washington: Pew Internet and American Life Project; 2018. May 31, [2020-05-05]. .
    1. Ancoli-Israel S, Cole R, Alessi C, Chambers M, Moorcroft W, Pollak CP. The role of actigraphy in the study of sleep and circadian rhythms. Sleep. 2003 May 01;26(3):342–392.
    1. Littner M, Kushida CA, Anderson WM, Bailey D, Berry RB, Davila DG, Hirshkowitz M, Kapen S, Kramer M, Loube D, Wise M, Johnson SF, Standards of Practice Committee of the American Academy of Sleep Medicine Practice parameters for the role of actigraphy in the study of sleep and circadian rhythms: an update for 2002. Sleep. 2003 May 01;26(3):337–341. doi: 10.1093/sleep/26.3.337.
    1. Lunsford-Avery JR, Engelhard MM, Navar AM, Kollins SH. Validation of the sleep regularity index in older adults and associations with cardiometabolic risk. Sci Rep-UK. 2018 Sep 21;8(1) doi: 10.1038/s41598-018-32402-5. doi: 10.1038/s41598-018-32402-5.
    1. Phillips A, Clerx W, O'Brien C, Sano A, Barger L, Picard R, Lockley S, Klerman E, Czeisler C. Irregular sleep/wake patterns are associated with poorer academic performance and delayed circadian and sleep/wake timing. Sci Rep-UK. 2017 Jun 12;7 doi: 10.1038/s41598-017-03171-4. doi: 10.1038/s41598-017-03171-4.
    1. Kam JWY, Griffin S, Shen A, Patel S, Hinrichs H, Heinze H, Deouell LY, Knight RT. Systematic comparison between a wireless EEG system with dry electrodes and a wired EEG system with wet electrodes. Neuroimage. 2019 Jan 01;184:119–129. doi: 10.1016/j.neuroimage.2018.09.012.

Source: PubMed