Dental water jet efficacy in the plaque control of orthodontic patients wearing fixed appliance: A randomized controlled trial

Sergio Mazzoleni, Alberto De Stefani, Carola Bordin, Paolo Balasso, Giovanni Bruno, Antonio Gracco, Sergio Mazzoleni, Alberto De Stefani, Carola Bordin, Paolo Balasso, Giovanni Bruno, Antonio Gracco

Abstract

Background: Different studies assess the role of fixed orthodontic appliances in supragingival plaque accumulation. In patients wearing fixed orthodontic appliances a good management of oral hygiene is required in order to prevent complication like as decay, enamel demineralization, gingivitis, gingival hyperplasia and periodontitis. The aim of this Randomized Controlled Trial (RCT) is to evaluate the efficacy of the use of a DWJ in patients under orthodontic treatment with fixed multibracket appliance.

Material and methods: The study design was single-blinded RCT with a split mouth protocol. Each patient followed a personal cleaning protocol using a DWJ in addition to traditional brushing only on one side while just brushing on the control side. The side on which was decided to use the DWJ was chosen randomly and the dental hygienist who took the measurements was blind. Plaque and gingival indexes were evaluated at baseline and at one, three and six-months follow-up.

Results: It did not emerge any difference in the plaque and gingival indexes trend between the two groups. Patients initially reported an worsening of the indexes at one month evaluation, then they set at baseline levels at three and six months.

Conclusions: The dental water jet does not improve significantly the efficacy of home oral hygiene in orthodontic patients wearing a multi-bracket fixed appliance. Patients did not show the traditional worsening during the whole orthodontic therapy. Key words:Dental water jet, fixed orthodontics, plaque index, gingival index.

Conflict of interest statement

Conflict of interest statement:The authors have declared that no conflict of interest exist.

Copyright: © 2019 Medicina Oral S.L.

Figures

Figure 1
Figure 1
Boxplot of Plaque Index (Incisiors-canines, premolars, molars) and Gingival Index Index (Incisiors-canines, premolars, molars) per group and time period.

References

    1. Sim HY, Kim HS, Jung DU, Lee H, Lee JW, Han K. Association between orthodontic treatment and periodontal diseases: Results from a national survey. Angle Orthod. 2017;87:651–657.
    1. Petti S, Barbato E, Simonetti D'Arca A. Effect of orthodontic therapy with fixed and removable appliances on oral microbiota: a six-month longitudinal study. New Microbiol. 1997;20:55–62.
    1. Lee SM, Yoo SY, Kim SH, Kim KW, Yoon YJ, Lim SH. Prevalence of putative periodontopathogens in subgingival dental plaques from gingivitis lesions in Korean orthodontic patients. J Microbiol. 2005;43:260–5.
    1. Jahn CA. The dental water jet: a historical review of the literature. J Dent Hyg. 2010;84:114–20.
    1. Al-Mubarak S, Ciancio S, Aljada A, Mohanty P, Ross C, Dandona P. Comparative evaluation of adjunctive oral irrigation in diabetics. J Clin Periodontol. 2002;29:295–300.
    1. Jolkovsky DL, Waki MY, Newman MG, Otomo-Corgel J, Madison M, Flemming TF. Clinical and microbiological effects of subgingival and gingival marginal irrigation with chlorhexidine gluconate. J Periodontol. 1990;61:663–9.
    1. Flemmig TF, Epp B, Funkenhauser Z, Newmann MG, Kornman KS, Haubitz I. Adjunctive supragingival irrigation with acetylsalicylic acid in periodontal supportive therapy. J Clin Periodontol. 1995;22:427–33.
    1. Newman MG, Flemmig TF, Nachnani S, Rodrigues A, Calsina G, Lee YS. Irrigation with 0.06% chlorhexidine in naturally occurring gingivitis. II. 6 months microbiological observations. J Periodontol. 1990;61:427–33.
    1. Fine JB, Harper DS, Gordon JM, Hovliaras CA, Charles CH. Short-term microbiological and clinical effects of subgingival irrigation with an antimicrobial mouthrinse. J Periodontol. 1994;65:30–6.
    1. Lyle DM. Relevance of water flosser: 50 years of data. Compend Contin Edc Dent. 2012;33:278–80, 282.
    1. Felo A, Shibly O, Ciancio SG, Lauciello FR, Ho A. Effects of subgingival chlorhexidine irrigation on peri-implant maintenance. Am J Dent. 1997;10:107–10.
    1. Rylev M, Kilian M. Prevalence and distribution of principal pathogens worldwide. J Clin Periodontol. 2008;35:346–61.
    1. Sharma NC, Lyle DM, Qaquish JG, Galustians J, Schuller R. The effect of a dental water jet with orthodontic tip on plaque and bleeding in adolescent patients with fixed orthodontic appliances. Am J Orthod Dentofacial Orthop. 2008;133:565–71.
    1. Klukowska M, Bader A, Erbe C, Bellamy P, White DJ, Anastasia MK. Plaque levels of patients with fixed orthodontic appliances measured by digital plaque image analysis. Am J Orthod Dentofacial Orthop. 2011;139:e463–70.
    1. Atassi F, Awartani F. Oral hygiene status among orthodontic patients. J Contemp Dent Pract. 2010;11:E025–32.
    1. Bollen AM, Cunha-Cruz J, Bakko DW, Huang GJ, Hujoel PP. The effects of orthodontic therapy on periodontal health: a systematic review of controlled evidence. J Am Dent Assoc. 2008;139:413–22.
    1. Zachrisson B. U, Alnaes L. Periodontal condition in orthodontically treated and untreated indivuduals. I. Loss of attachment, gingival pocket depth and clinical crown height. Angle Orthod. 1973;43:402–11.
    1. Boke F, Gazioglu C, Akkaya S, Akkaya M. Relationship between orthodontic treatment and gingival health: A retrospective study. Eur J Dent. 2014;8:373–80.
    1. Zachrisson S, Zachrisson BU. Gingival condition associated with orthodontic treatment. Angle Orthod. 1972;42:26–34.
    1. Liu H, Sun J, Dong Y, Lu H, Zhou H, Hansen BF. Periodontal health and relative quantity of subgingival Porphyromonas gingivalis during orthodontic treatment. Angle Orthod. 2011;81:609–15.
    1. Muhler JC. Comparative frequency of use of the electric toothbrush and hand toothbrush. J Periodontol. 1969;40:268–70.
    1. Camorali C. The role of the dental hygienist in orthodontic practice. Prev Assist Dent. 1991;17:39–43.
    1. Bergkulla N, Hänninen H, Alanko O, Tuonmisto M, Miettinen A, Svedstrom-Oristo AL. Introduction and assessment of orthognathic information clinic. Eur J Orthod. 2017;39:660–664.
    1. Burch JG, Lanese R, Ngan P. A two-month study of the effects of oral irrigation and automatic toothbrush use in an adult orthodontic population with fixed appliances. Am J Orthod Dentofacial Orthop. 1994;106:121–6.
    1. Hurst JE, Madonia JV. The effect of an oral irrigating device on the oral hygiene of orthodontic patients. J Am Dent Assoc. 1970;81:678–82.

Source: PubMed

3
Předplatit