An artificial pancreas (AP) is a control system for automatic insulin delivery. The investigators have implemented a high blood sugar detection and dosing algorithm for use within an AP control system. If a high blood sugar pattern is detected, correction insulin will be calculated and delivered. The investigators will test how well the new algorithm manages glucose compared to the AP control system without high blood sugar detection and dosing. This type of algorithm may improve glucose control for high risk patient populations.

Studieoversigt

Status

Afsluttet

Betingelser

Detaljeret beskrivelse

Participants will be on study for approximately 4 weeks. During the study, participants will wear an Omnipod to deliver insulin. Participants will also wear a Dexcom G6 CGM. The CGM system will send sensed glucose data every 5 minutes wirelessly via Bluetooth Low Energy (BTLE) to an Android smartphone running the iPancreas app. The closed-loop system will receive activity data through an activity watch worn by the participant. Participants will complete system training on Day 1 in clinic and then spend the rest of the 4 weeks under free-living conditions. The first 3 weeks of the study will be the training period when the system will collect patterns from the glucose sensor, insulin, and fitness data that lead to high blood sugar. After the 3-week training period, participants will complete a virtual visit to train the participant on the high blood sugar detection and dosing algorithm, then continue to use for an additional week. Participants will complete meal and exercise challenges.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

10

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Oregon
      • Portland, Oregon, Forenede Stater, 97239
        • Oregon Health and Science University

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 100 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Diagnosis of type 1 diabetes mellitus for at least 1 year.
  • Male or female participants 18 and older.
  • HbA1c or GMI ≥ 7.0% at screening.
  • Physically willing and able to perform 30 min of exercise (as determined by the investigator after reviewing the participant's activity level).
  • Current use of an FDA-approved hybrid closed loop system for ≥3 months.
  • Lives with another person age 18 or older who will sleep in the house at night and that can attend the training on using the system.
  • Lives within 40 miles of OHSU
  • Total daily insulin requirement is less than 139 units/day.
  • Able to read, write and understand spoken English
  • Current use of a smartphone so can be contacted by study staff off-campus.
  • Willingness to follow all study procedures, including attending all clinic visits.
  • Willingness to sign informed consent and HIPAA documents.

Exclusion Criteria:

  • GMI or A1c <6.5% or >10.5%
  • Sensor glucose shows < 2% of time above 250 mg/dl in last 30 days.
  • Individual of childbearing potential who is pregnant or intending to become pregnant or breast-feeding, or is not using adequate contraceptive methods. Acceptable contraception includes birth control pill / patch / vaginal ring, Depo-Provera, Norplant, an IUD, the double barrier method (the woman uses a diaphragm and spermicide and the man uses a condom), or abstinence.
  • Any cardiovascular disease, defined as a clinically significant EKG abnormality at the time of screening or any history of: stroke, heart failure, myocardial infarction, angina pectoris, or coronary arterial bypass graft or angioplasty. Diagnosis of 2nd or 3rd degree heart block or any non-physiological arrhythmia judged by the investigator to be exclusionary.
  • Renal insufficiency (GFR < 60 ml/min, using the MDRD equation as reported by the OHSU laboratory).
  • Liver failure, cirrhosis, or any other liver disease that compromises liver function as determined by the investigator.
  • History of severe hypoglycemia during the past 6 months prior to screening visit or hypoglycemia unawareness as judged by the investigator. Participants will complete a hypoglycemia awareness questionnaire. Participants will be excluded for four or more R responses.
  • History of diabetes ketoacidosis during the prior 6 months prior to screening visit, as diagnosed on hospital admission or as judged by the investigator.
  • Adrenal insufficiency.
  • Any active infection (example skin infection requiring antibiotics)
  • Known or suspected abuse of alcohol, narcotics, or illicit drugs.
  • Seizure disorder.
  • Active foot ulceration.
  • Peripheral arterial disease.
  • Major surgical operation within 30 days prior to screening.
  • Use of an investigational drug within 30 days prior to screening.
  • Chronic usage of any immunosuppressive medication (such as cyclosporine, azathioprine, sirolimus, or tacrolimus).
  • Bleeding disorder or platelet count below 50,000.
  • Allergy to Fiasp insulin
  • Current administration of oral or parenteral corticosteroids.
  • Any life threatening disease, including malignant neoplasms and medical history of malignant neoplasms within the past 5 years prior to screening (except basal and squamous cell skin cancer).
  • Use of beta blockers or non-dihydropyridine calcium channel blockers.
  • Current use of any medication that can lower glucose other than insulin (ex. Wegovy, Jardiance) with the exception of metformin if dose has been stable for ≥3 months and patient willing to not change dose during study.
  • Gastroparesis
  • Diet consisting of less than 50 grams of carbohydrates per day.
  • A positive response to any of the questions from the Physical Activity Readiness Questionnaire with one exception: participant will not be excluded if he/she takes a single blood pressure medication that doesn't impact heart rate and blood pressure is controlled on the medication (blood pressure is less than 140/90 mmHg).
  • Any chest discomfort with physical activity, including pain or pressure, or other types of discomfort.
  • Any clinically significant disease or disorder which in the opinion of the Investigator may jeopardize the participant's safety or compliance with the protocol.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: iPancreas automated insulin delivery system

Participants will use the iPancreas automated insulin delivery system for 4 weeks at home. After 3 weeks of collecting high blood sugar pattern data, the high blood sugar pattern detection and dosing feature will be turned on.

The Model Predictive Control (MPC) insulin infusion algorithm contains a model within the controller that takes as an input the aerobic metabolic expenditure in addition to the CGM and meal in puts. The algorithm uses heart rate and accelerometer data collected on the patient's body to calculate metabolic expenditure (METs). The METs then acts on the model for the insulin dynamics, whereby more energy expenditure and longer duration exercise can lead to a more substantial effect of insulin on the CGM. The MPC also has missed meal insulin bolus detection where the system will calculate the amount of insulin that was missed for a meal. The missed meal boluses can be delivered automatically without any input from the user. This feature can also be disabled. The MPC has a new feature called hyperglycemia pattern detection and dosing algorithm that will analyze problem patterns associated with high blood sugar and automatically calculate and deliver a correction dose.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Percent of Time With Sensor Glucose Less Than 70 mg/dl
Tidsramme: 2-hours after pattern detected during week 4

Assess the percent of time that the Dexcom G6 reported sensor glucose values less than 70 mg/dl during the 2-hours after patterns were detected during week 4.

2-hours after pattern detected during week 4
Percent of Time With Sensor Glucose Less Than 54 mg/dl
Tidsramme: 2-hours after pattern detected during week 4

Assess the percent of time that the Dexcom G6 reported sensor glucose values less than 54 mg/dl during the 2-hours after patterns were detected during week 4.

2-hours after pattern detected during week 4
Percent of Time the Pattern Evaluation Windows Occurred
Tidsramme: week 4 intervention

To assess feasibility of the system by evaluating the percent time that the pattern detection is active in detecting hyperglycemic patterns and dosing for them during the pattern evaluation windows. Percent time pattern evaluation windows occurred for the study period is calculated as (minutes in pattern evaluation window) / (total minutes) * 100

week 4 intervention
Difference in Percent of Time With Sensor Glucose Greater Than 250 mg/dl
Tidsramme: 2-hours after pattern detected occurred in weeks 1-3

Assess the difference in the percent of time CGM was greater than 250 mg/dl during the 2-hour pattern evaluation windows occurring in week 4 minus the percent time that CGM was greater than 250 mg/dL during the 2-hour pattern evaluation windows occurring in weeks 1-3 .

2-hours after pattern detected occurred in weeks 1-3

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Difference in Percent of Time With Sensor Glucose 70 to 180 mg/dl
Tidsramme: 2 hours after pattern detected occurred in weeks 1-3

Assess the difference in the percent of time CGM was 70-180 mg/dL during the 2-hour pattern evaluation windows occurring in week 4 minus the percent time that CGM was 70-180 mg/dL during the 2-hour pattern evaluation windows occurring in weeks 1-3 .

2 hours after pattern detected occurred in weeks 1-3
Difference in Percent of Time With Sensor Glucose 70 to 140 mg/dl
Tidsramme: 2 hours after pattern detected occurred in weeks 1-3

Assess the difference in the percent of time CGM was 70-140 mg/dL during the 2-hour pattern evaluation windows occurring in week 4 minus the percent time that CGM was 70-140 mg/dL during the 2-hour pattern evaluation windows occurring in weeks 1-3 .

2 hours after pattern detected occurred in weeks 1-3
Difference in Percent of Time With Sensor Glucose Greater Than 180 mg/dl
Tidsramme: 2 hours after pattern detected occurred in weeks 1-3

Assess the difference in the percent of time CGM was >180 mg/dL during the 2-hour pattern evaluation windows occurring in week 4 minus the percent time that CGM was >180 mg/dL during the 2-hour pattern evaluation windows occurring in weeks 1-3 .

2 hours after pattern detected occurred in weeks 1-3
Difference in Coefficient of Variation of Glucose
Tidsramme: 2 hours after pattern detected occurred in weeks 1-3

Assess the difference in the CGM coefficient of variation during the 2-hour pattern evaluation windows occurring in week 4 minus the CGM coefficient of variation during the 2-hour pattern evaluation windows occurring in weeks 1-3 .

2 hours after pattern detected occurred in weeks 1-3
Difference in Insulin Delivered
Tidsramme: 2 hours after pattern detected occurred in weeks 1-3

Assess the difference in the insulin delivered during the 2-hour pattern evaluation windows occurring in week 4 minus the insulin delivered during the 2-hour pattern evaluation windows occurring in weeks 1-3 .

2 hours after pattern detected occurred in weeks 1-3
Difference in Hypoglycemia Treatments
Tidsramme: 2 hours after pattern detected occurred in weeks 1-3

Assess the difference in the hypoglycemia carbohydrate treatments during the 2-hour pattern evaluation windows occurring in week 4 minus the hypoglycemia carbohydrate treatments during the 2-hour pattern evaluation windows occurring in weeks 1-3 .

2 hours after pattern detected occurred in weeks 1-3

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Leah Wilson, MD, Oregon Health and Science University

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

25. november 2024

Primær færdiggørelse (Faktiske)

17. april 2026

Studieafslutning (Faktiske)

17. april 2026

Datoer for studieregistrering

Først indsendt

4. november 2024

Først indsendt, der opfyldte QC-kriterier

4. november 2024

Først opslået (Faktiske)

6. november 2024

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

25. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

3. november 2026

Sidst verificeret

1. oktober 2026

Mere information

Begreber relateret til denne undersøgelse

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

UBESLUTET

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ja

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner