- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT03778437
Facilitating Needle Alignment With Aiming Method
20 de septiembre de 2020 actualizado por: Qingxiang Mao, Daping Hospital and the Research Institute of Surgery of the Third Military Medical University
Aiming Method May Facilitate Needle Alignment in Ultrasound-guided Subclavian Vein Catheterization
Although ultrasound-guided catheterization of the subclavian vein is becoming standard procedure in anesthetic practice, failure to align the needle and the transducer still can lead to possibly complications.
In this study, we proposed a new alignment method, namely Aiming Method.
The purpose of this study is to investigate whether the use of this aiming method improved resident volunteers' performance of ultrasound-guided SC insertion in real patients.
Specifically, residents were asked to perform three different methods: landmark techniques, ultrasound-guided with aiming method and ultrasound-guided plus needle guide techniques.
Descripción general del estudio
Estado
Terminado
Condiciones
Tipo de estudio
Intervencionista
Inscripción (Actual)
474
Fase
- No aplica
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
-
Chongqing, Porcelana, 400042
- Daping Hospital
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
18 años a 70 años (Adulto, Adulto Mayor)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Todos
Descripción
Inclusion Criteria:
- 18 years to 70 years
- American Society of Anesthesiologists (ASA) Physical Status Ⅰ-Ⅲ
- Elective surgery patients requiring subclavian vein catheterization
Exclusion Criteria:
- Local anatomic abnormalities in subclavicular area
- Preexisting subclavian vein thrombosis or coagulation disorders
- Refusal of subclavian vein catheterization
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Prevención
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Único
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Comparador activo: landmark techniques
Subclavian vein catheterization is performed without the guidance of ultrasound.
The needle was inserted 1 cm inferior and 1 cm lateral to the junction of the middle and medial thirds of the clavicle (infraclavicular approach)
|
The patient is positioned in Tredelenburg with the arm abducted to 90°.
Venipuncture should occur 1 cm lateral to the curvature of the middle third of the clavicle with the needle pointing horizontally directed at the sternal notch.
If subclavian vein is missing at the first try, withdraw the needle and direct horizontally at the cricoid cartilage at the second try.
|
|
Experimental: ultrasound-guided with aiming method
Subclavian vein catheterization is performed with our newly proposed aiming method with the guidance of ultrasound.
|
Here we introduced a new freehand method, named as Aiming Method, which facilitated the alignment of injection needles with ultrasound beams.
During this aiming method, patient is still positioned in Tredelenburg with the arm abducted to 90° and no needle guidance will be used.
|
|
Experimental: ultrasound-guided plus needle guide techniques
Subclavian vein catheterization is performed under ultrasound guidance with in-plane technique.
|
Subclavian vein catheterization is performed under ultrasound guidance with in-plane technique.
The patient is positioned in Tredelenburg with the arm abducted to 90°.
During the needle insertion, the needle is secured in the needle guidance device which keeps the alignment of needle and ultrasonic beam.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Procedural time
Periodo de tiempo: 24 hours
|
the time from skin break to guide wire was positioned into the subclavian vein
|
24 hours
|
|
Number of skin breaks
Periodo de tiempo: 24 hours
|
number of skin punctures
|
24 hours
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
The incidence of arterial puncture
Periodo de tiempo: 24 hours
|
aspiration of arterial blood during needle insertion or local haematoma in ultrasound image
|
24 hours
|
|
The incidence of pneumothorax
Periodo de tiempo: 24 hours
|
aspiration of air during needle insertion, or thoracic ultrasonography, or chest radiography
|
24 hours
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio (Actual)
12 de febrero de 2019
Finalización primaria (Actual)
20 de diciembre de 2019
Finalización del estudio (Actual)
27 de diciembre de 2019
Fechas de registro del estudio
Enviado por primera vez
3 de diciembre de 2018
Primero enviado que cumplió con los criterios de control de calidad
14 de diciembre de 2018
Publicado por primera vez (Actual)
19 de diciembre de 2018
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
23 de septiembre de 2020
Última actualización enviada que cumplió con los criterios de control de calidad
20 de septiembre de 2020
Última verificación
1 de septiembre de 2020
Más información
Términos relacionados con este estudio
Otros números de identificación del estudio
- 2018(45)
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
No
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
No
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .