Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Facilitating Needle Alignment With Aiming Method

Aiming Method May Facilitate Needle Alignment in Ultrasound-guided Subclavian Vein Catheterization

Although ultrasound-guided catheterization of the subclavian vein is becoming standard procedure in anesthetic practice, failure to align the needle and the transducer still can lead to possibly complications. In this study, we proposed a new alignment method, namely Aiming Method. The purpose of this study is to investigate whether the use of this aiming method improved resident volunteers' performance of ultrasound-guided SC insertion in real patients. Specifically, residents were asked to perform three different methods: landmark techniques, ultrasound-guided with aiming method and ultrasound-guided plus needle guide techniques.

Studienübersicht

Studientyp

Interventionell

Einschreibung (Tatsächlich)

474

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Chongqing, China, 400042
        • Daping Hospital

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre bis 70 Jahre (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • 18 years to 70 years
  • American Society of Anesthesiologists (ASA) Physical Status Ⅰ-Ⅲ
  • Elective surgery patients requiring subclavian vein catheterization

Exclusion Criteria:

  • Local anatomic abnormalities in subclavicular area
  • Preexisting subclavian vein thrombosis or coagulation disorders
  • Refusal of subclavian vein catheterization

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Verhütung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Single

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Aktiver Komparator: landmark techniques
Subclavian vein catheterization is performed without the guidance of ultrasound. The needle was inserted 1 cm inferior and 1 cm lateral to the junction of the middle and medial thirds of the clavicle (infraclavicular approach)
The patient is positioned in Tredelenburg with the arm abducted to 90°. Venipuncture should occur 1 cm lateral to the curvature of the middle third of the clavicle with the needle pointing horizontally directed at the sternal notch. If subclavian vein is missing at the first try, withdraw the needle and direct horizontally at the cricoid cartilage at the second try.
Experimental: ultrasound-guided with aiming method
Subclavian vein catheterization is performed with our newly proposed aiming method with the guidance of ultrasound.
Here we introduced a new freehand method, named as Aiming Method, which facilitated the alignment of injection needles with ultrasound beams. During this aiming method, patient is still positioned in Tredelenburg with the arm abducted to 90° and no needle guidance will be used.
Experimental: ultrasound-guided plus needle guide techniques
Subclavian vein catheterization is performed under ultrasound guidance with in-plane technique.
Subclavian vein catheterization is performed under ultrasound guidance with in-plane technique. The patient is positioned in Tredelenburg with the arm abducted to 90°. During the needle insertion, the needle is secured in the needle guidance device which keeps the alignment of needle and ultrasonic beam.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Procedural time
Zeitfenster: 24 hours
the time from skin break to guide wire was positioned into the subclavian vein
24 hours
Number of skin breaks
Zeitfenster: 24 hours
number of skin punctures
24 hours

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
The incidence of arterial puncture
Zeitfenster: 24 hours
aspiration of arterial blood during needle insertion or local haematoma in ultrasound image
24 hours
The incidence of pneumothorax
Zeitfenster: 24 hours
aspiration of air during needle insertion, or thoracic ultrasonography, or chest radiography
24 hours

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

12. Februar 2019

Primärer Abschluss (Tatsächlich)

20. Dezember 2019

Studienabschluss (Tatsächlich)

27. Dezember 2019

Studienanmeldedaten

Zuerst eingereicht

3. Dezember 2018

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

14. Dezember 2018

Zuerst gepostet (Tatsächlich)

19. Dezember 2018

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

23. September 2020

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

20. September 2020

Zuletzt verifiziert

1. September 2020

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • 2018(45)

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Zentralvenöser Katheter

Klinische Studien zur landmark techniques

Abonnieren