- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT03778437
Facilitating Needle Alignment With Aiming Method
20. september 2020 opdateret af: Qingxiang Mao, Daping Hospital and the Research Institute of Surgery of the Third Military Medical University
Aiming Method May Facilitate Needle Alignment in Ultrasound-guided Subclavian Vein Catheterization
Although ultrasound-guided catheterization of the subclavian vein is becoming standard procedure in anesthetic practice, failure to align the needle and the transducer still can lead to possibly complications.
In this study, we proposed a new alignment method, namely Aiming Method.
The purpose of this study is to investigate whether the use of this aiming method improved resident volunteers' performance of ultrasound-guided SC insertion in real patients.
Specifically, residents were asked to perform three different methods: landmark techniques, ultrasound-guided with aiming method and ultrasound-guided plus needle guide techniques.
Studieoversigt
Status
Afsluttet
Betingelser
Undersøgelsestype
Interventionel
Tilmelding (Faktiske)
474
Fase
- Ikke anvendelig
Kontakter og lokationer
Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.
Studiesteder
-
-
-
Chongqing, Kina, 400042
- Daping Hospital
-
-
Deltagelseskriterier
Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.
Berettigelseskriterier
Aldre berettiget til at studere
18 år til 70 år (Voksen, Ældre voksen)
Tager imod sunde frivillige
Ingen
Køn, der er berettiget til at studere
Alle
Beskrivelse
Inclusion Criteria:
- 18 years to 70 years
- American Society of Anesthesiologists (ASA) Physical Status Ⅰ-Ⅲ
- Elective surgery patients requiring subclavian vein catheterization
Exclusion Criteria:
- Local anatomic abnormalities in subclavicular area
- Preexisting subclavian vein thrombosis or coagulation disorders
- Refusal of subclavian vein catheterization
Studieplan
Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Forebyggelse
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Enkelt
Våben og indgreb
Deltagergruppe / Arm |
Intervention / Behandling |
|---|---|
|
Aktiv komparator: landmark techniques
Subclavian vein catheterization is performed without the guidance of ultrasound.
The needle was inserted 1 cm inferior and 1 cm lateral to the junction of the middle and medial thirds of the clavicle (infraclavicular approach)
|
The patient is positioned in Tredelenburg with the arm abducted to 90°.
Venipuncture should occur 1 cm lateral to the curvature of the middle third of the clavicle with the needle pointing horizontally directed at the sternal notch.
If subclavian vein is missing at the first try, withdraw the needle and direct horizontally at the cricoid cartilage at the second try.
|
|
Eksperimentel: ultrasound-guided with aiming method
Subclavian vein catheterization is performed with our newly proposed aiming method with the guidance of ultrasound.
|
Here we introduced a new freehand method, named as Aiming Method, which facilitated the alignment of injection needles with ultrasound beams.
During this aiming method, patient is still positioned in Tredelenburg with the arm abducted to 90° and no needle guidance will be used.
|
|
Eksperimentel: ultrasound-guided plus needle guide techniques
Subclavian vein catheterization is performed under ultrasound guidance with in-plane technique.
|
Subclavian vein catheterization is performed under ultrasound guidance with in-plane technique.
The patient is positioned in Tredelenburg with the arm abducted to 90°.
During the needle insertion, the needle is secured in the needle guidance device which keeps the alignment of needle and ultrasonic beam.
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Procedural time
Tidsramme: 24 hours
|
the time from skin break to guide wire was positioned into the subclavian vein
|
24 hours
|
|
Number of skin breaks
Tidsramme: 24 hours
|
number of skin punctures
|
24 hours
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
The incidence of arterial puncture
Tidsramme: 24 hours
|
aspiration of arterial blood during needle insertion or local haematoma in ultrasound image
|
24 hours
|
|
The incidence of pneumothorax
Tidsramme: 24 hours
|
aspiration of air during needle insertion, or thoracic ultrasonography, or chest radiography
|
24 hours
|
Samarbejdspartnere og efterforskere
Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.
Datoer for undersøgelser
Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.
Studer store datoer
Studiestart (Faktiske)
12. februar 2019
Primær færdiggørelse (Faktiske)
20. december 2019
Studieafslutning (Faktiske)
27. december 2019
Datoer for studieregistrering
Først indsendt
3. december 2018
Først indsendt, der opfyldte QC-kriterier
14. december 2018
Først opslået (Faktiske)
19. december 2018
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
23. september 2020
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
20. september 2020
Sidst verificeret
1. september 2020
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
- 2018(45)
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Ingen
Studerer et amerikansk FDA-reguleret enhedsprodukt
Ingen
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Centrale venekatetre
-
Feeltect LimitedParkview HealthIkke rekrutterer endnuVenous bensår (VLUS)Forenede Stater
-
StimLabsIkke rekrutterer endnuBensår | Venøse bensår | Bensår Venøs | Venøst ben | Venous bensår (VLUS)
-
Washington University School of MedicineAfsluttet
-
Sun Yat-sen UniversityIkke rekrutterer endnuCentral serøs chorioretinopati (CSC)Kina
-
Seoul National University HospitalSMG-SNU Boramae Medical CenterIkke rekrutterer endnuCentral venekateteriseringKorea, Republikken
-
Centre Hospitalier Universitaire de NīmesAfsluttetCentral venekateteriseringFrankrig
-
Masarykova Nemocnice v Usti nad Labem, Krajska...AfsluttetCentral venekateterTjekkiet
-
Brno University HospitalAfsluttet
-
Seoul National University HospitalSMG-SNU Boramae Medical CenterUkendtCentral venekateterisering
-
Sun Yat-sen UniversityAfsluttetAkut central serøs chorioretinopatiKina
Kliniske forsøg med landmark techniques
-
Medical College of WisconsinAktiv, ikke rekrutterendeKnoglemarvsbiopsiprocedureForenede Stater
-
Dartmouth-Hitchcock Medical CenterAfsluttet
-
Aga Khan University Hospital, PakistanAfsluttet
-
Aksaray UniversityIkke rekrutterer endnuTrakeostomi komplikation | Perkutan trakeostomi | Luftvejstraumer | Trakeostomi blødningKalkun
-
Patel Hospital, PakistanAfsluttet
-
Cangzhou Hospital of Integrated Traditional Chinese...Afsluttet
-
Children's Hospital of PhiladelphiaAktiv, ikke rekrutterende
-
Equipo de Terapia IntravenosaHospital San Carlos, MadridAfsluttet
-
Karaman Training and Research HospitalAfsluttetFedme, sygeligTyrkiet (Türkiye)