- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07697976
DRF Reposition Manual Reduction vs Finger-trap Traction (RepoDRF2)
Unterschied Der Reposition in Bruchspaltanästhesie Zur Reposition im Aushang Bei Einer Distalen Radiusfraktur - Eine Prospektiv Randomisierte Studie
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Participants have sustained a distal radius fracture treated with cast immobilization. Two common conservative management approaches are being compared: (1) closed reduction under a local anesthetic (hematoma block) followed by traction and casting, and (2) immobilization after traction alone without formal reduction under anesthesia.
While the first method aims to restore anatomical alignment initially, loss of reduction may occur over time. The second method improves alignment but does not attempt full anatomical reduction.
The study hypothesis is that both approaches result in similar wrist alignment and functional outcomes after completion of treatment. The objective of this study is to determine whether reduction under local anesthesia followed by traction provides any advantage over traction alone in patients with distal radius fractures.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Tyrol
-
Innsbruck, Tyrol, Austria, 6020
- Univ.-Klinik für Orthopädie und Traumatologie
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
Dorsally tilted distal radius fracture (DRF) > 10° (intra-articular or extra-articular) Dorsal comminution of the distal radius fracture
Fracture classification (AO), dorsally displaced:
- A2
- A3
- C1
- C2
- C3
Exclusion Criteria:
- Age under 18 years
- Non-displaced fractures of the radius
- Previous palmar displaced fractures of the radius
- Displacement greater than one shaft width
- Open fractures of the radius
- Bilateral radius fractures
- History of a previous radius fracture
- Inability to provide informed consent due to physical or mental disability
- Unavailability for follow-up examinations (e.g., abroad, polytrauma)
- Lack of full legal capacity
- Alcohol or drug abuse
- Allergy to local anesthetics
- Median nerve irritation
- Pregnancy
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Comparador activo: R: Manual Reduction
|
Hematoma block 5 mL 2% lidocaine, followed by 15 minutes finger-trap traction and then manual reduction + cast application
|
|
Experimental: A: Finger-trap traction
|
15 minutes finger-trap traction only and then cast application
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Pain difference between the groups
Periodo de tiempo: From enrollment (Baseline) to the 12month Follow Up.
|
Comparison of the pain score in the course of the follow ups between the groups.
0= no pain 10 = worst pain (maximal pain)
|
From enrollment (Baseline) to the 12month Follow Up.
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
MHQ Hand Score (Patient reported outcome)
Periodo de tiempo: Enrollment until 12 month follow up
|
Difference in functional outcome measured with MHQ (Michigan Hand Outcome Questionaire) between the two groups.
0 points= very poor hand function / maximum impairment; 100 points → optimal hand function, no impairment.
|
Enrollment until 12 month follow up
|
|
PRWE - Patient reported outcome
Periodo de tiempo: Enrollment until 12month follow up
|
Difference in functional outcome measured with PRWE (Patient-rated wrist evaluation) between the two groups.
0 points= optimal hand function, no impairment; 100 points → very poor hand function / maximum impairment.
|
Enrollment until 12month follow up
|
|
Grip strength
Periodo de tiempo: 12 weeks until 12mo Follow up
|
Difference in grip strength measured with dynanometer between the two groups.
Grip strength is compared to the contralateral non-injured wrist.
|
12 weeks until 12mo Follow up
|
|
Range of motion - functional outcome
Periodo de tiempo: 12 weeks until 12 mo follow-up
|
Difference in functional outcome (range of motion) measured with goniometer after treatment between the two groups.
Range of Motion is compared to the contraltaeral non-injured wrist.
|
12 weeks until 12 mo follow-up
|
|
Radiological outcome
Periodo de tiempo: Enrollment until 12 month Follow up
|
Difference in radiological outcome between the two groups; especially, dorsal tilt, radial inclination and ulnar variance.
|
Enrollment until 12 month Follow up
|
|
Complications
Periodo de tiempo: After treatment until 12 month Follow up
|
Complications between the two groups.
|
After treatment until 12 month Follow up
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- RepoDRF2
- AOTrauma Research Austria 2020 (Otro número de subvención/financiamiento: AO Trauma)
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .