- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT06077396
Vaikuttaako säteittäinen valtimon kanylointi käden perfuusioindeksiin (PI) maksansiirtoleikkauksissa? (radial artery)
Vaikuttaako säteittäisvaltimon kanylaatio maksansiirron käden perfuusioindeksiin?
This randomized controlled trial compared palpation-guided and ultrasound-guided radial artery catheterization in adult liver transplant recipients. The primary outcome was the change in perfusion index (Pi) from baseline after catheterization. Secondary outcomes included first-attempt success, number of skin punctures, procedure time, overall success with the assigned technique, and local complications.
Tutkimuksen yleiskatsaus
Tila
Interventio / Hoito
Yksityiskohtainen kuvaus
## DLiver transplantation is associated with major hemodynamic changes, and continuous invasive arterial pressure monitoring is an essential part of perioperative management. The radial artery is the most commonly used site. Repeated punctures and mechanical trauma during catheterization may cause local complications and affect peripheral perfusion. Ultrasound guidance may facilitate catheter placement with fewer punctures.
The perfusion index (Pi), derived from pulse oximetry, is the ratio of the pulsatile to the non-pulsatile optical signal and is used to monitor peripheral perfusion. Because Pi is also influenced by systemic hemodynamics, sympathetic activity, temperature, nociception and drugs, changes in Pi were not interpreted as direct evidence of radial artery vasospasm.
In this prospective, randomized, controlled, two-arm parallel-group trial, adult liver transplant recipients were randomized 1:1 to palpation-guided or ultrasound-guided radial artery catheterization. Randomization used a computer-generated sequence and sequentially numbered, opaque, sealed envelopes prepared by an independent person. The envelope was opened after induction of general anesthesia, once hemodynamic stability was achieved and immediately before catheterization. All procedures were performed by a single anesthesiologist experienced in both techniques, using the same 20-gauge non-guidewire arterial cannula in both groups, preferably on the non-dominant hand after a normal modified Allen test.
In the ultrasound group, a high-frequency linear probe was used with a short-axis out-of-plane approach and dynamic needle tip positioning. Pi was measured continuously with a pulse oximetry sensor placed on the index finger the hand. Pi, heart rate, SpO2, pleth variability index (PVI), SpHb and SpOC were recorded immediately before catheterization (baseline) and immediately after catheterization; Pi was additionally recorded 5 and 10 minutes after catheterization.
The primary outcome was the change in Pi from baseline over time. The primary analysis used a linear mixed-effects model including group, time and the group-by-time interaction to account for repeated measurements. Secondary outcomes were compared with appropriate tests (t test or Mann-Whitney U test; chi-square or Fisher's exact test). Results were reported with effect estimates and 95% confidence intervals; a two-sided p<0.05 was considered statistically significant.
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskeluyhteys
- Nimi: duygu demiroz
- Puhelinnumero: 905319504421
- Sähköposti: drduygudemiroz@hotmail.com
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Adult patients (18 years of age or older) undergoing liver transplantation.
- Patients eligible for radial artery catheterization as part of perioperative monitoring.
- Patients who provide informed consent to participate in the study.
Exclusion Criteria:
- Patients in whom radial artery catheterization is contraindicated.
- Patients who do not provide informed consent to participate in the study.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Hoito
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Muut: Conventional Palpation
Conventional Palpation |
Radial artery catheterization was performed after induction of general anesthesia, preferably on the non-dominant hand after a normal modified Allen test. The radial pulse was identified by palpation and the artery was cannulated using anatomical landmarks with a 20-gauge non-guidewire arterial cannula, the same cannula used in the ultrasound group. The procedure was limited to a maximum of three skin punctures. |
|
Muut: Guided Catheterization
-Radial artery catheterization was performed after induction of general anesthesia using the conventional palpation technique. The radial pulse was identified by palpation and the artery was cannulated using anatomical landmarks with a 20-gauge non-guidewire arterial cannula, limited to a maximum of three skin punctures. |
Radial artery catheterization performed under real-time ultrasound guidance using an integrated guidewire arterial cannula system. |
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Change in Perfusion Index from Baseline Following Radial Artery Catheterization
Aikaikkuna: Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to evaluate changes in peripheral perfusion.
|
Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to assess changes in peripheral perfusion between the palpation-guided and ultrasound-guided catheterization groups. |
Perfusion index (Pi) will be measured at baseline, immediately after radial artery catheterization, and at 5 and 10 minutes after the procedure to evaluate changes in peripheral perfusion.
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
First-Attempt Radial Artery Catheterization Success Rate
Aikaikkuna: During the catheterization procedure
|
The proportion of participants in whom radial artery catheterization is successfully completed on the first skin puncture. |
During the catheterization procedure
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Päätutkija: duygu demiröz, INONU UNİVERSİTY
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Brzezinski M, Luisetti T, London MJ. Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations. Anesth Analg. 2009 Dec;109(6):1763-81. doi: 10.1213/ANE.0b013e3181bbd416.
- Numaguchi A, Adachi YU, Aoki Y, Ishii Y, Suzuki K, Obata Y, Sato S, Nishiwaki K, Matsuda N. Radial artery cannulation decreases the distal arterial blood flow measured by power Doppler ultrasound. J Clin Monit Comput. 2015 Oct;29(5):653-7. doi: 10.1007/s10877-014-9648-5. Epub 2014 Dec 16.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Arvioitu)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muut tutkimustunnusnumerot
- INU-LT-RAC-2026-01
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .